ML19326B284

From kanterella
Jump to navigation Jump to search
Forwards Deficiency Evaluation Rept, Reactor Vessel Surveillance Capsule Holder Tubes Holddown Mechanism
ML19326B284
Person / Time
Site: Davis Besse, Oconee, Arkansas Nuclear, Crystal River, Rancho Seco, Midland, Crane  
Issue date: 04/21/1976
From: Suhrke K
BABCOCK & WILCOX CO.
To: Volgenau E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 8003160113
Download: ML19326B284 (1)


Text

_ _ _ _ _ _ - _ _ _

w;. :n v ab 00h & N!!!COX ec, er cenerauen creun P.O. Box 1260. Lynchburg. Va. 24505 Te'ephone: (804) 384-5111 April 21, 1976 y\\ \\ I?!l g Dr. Ernest'Vogenau,-Director

/

k T'

Q k(g,,,,, ! !.,* (tj Offic,e of Inspection and Enforcement g

U.S.. Nuclear Regulatory Cor:: mission Washington, D. C.

20555 9

ggg.,,--

Dear Dr. Vogenau:

M, u.s. gg',yg7'*"

/

b.

u.a s-n Enclosed are ten (10) copies of the significant 6.-

g' deficiency evaluation related to the reactor vessel sur-6'# / jg(t s N veillance capsule holder tubes on certain B&W plants.

4 The corrective action being performed on the plants involved will be reported by the individual licensees in accordance with their individual situation.

If further infor-mation is required on this subject, please feel free to contact Mr. W. J. Keyworth, Operating Plant Licensing Unit Manager (Ext. 2211).

Very truly yours, BABC0CK & WILCOX COMPriY Nuclear Power Generation ff

/v M Kenneth E. Suhrke Manager, Licensing KES/db Encis.

cc:

Mr. J. F. Stolz (NRC)

Mr. R.1B. Borsum (B&W) (2)

, e n m.m

'.t +4 J ~

The Batcock & Wilcox Company / Estab!ished 1867-

-- 89,03160 (v3 y

.