ML19326B273

From kanterella
Jump to navigation Jump to search
Notifies That Util Aware of B&W Dec 1977 Discovery of Failure to Assume Worst Case Stuck Rod in Shutdown Margin Calculations for Several Early Plants.Facility Not One of These Plants
ML19326B273
Person / Time
Site: Crystal River 
Issue date: 10/05/1978
From: Stewart W
FLORIDA POWER CORP.
To: Reid R
Office of Nuclear Reactor Regulation
References
NUDOCS 8003160103
Download: ML19326B273 (3)


Text

.

DO c

REGULATORY INFORMATION DISTRIBUTION SYSTEM DOC DATE:

7Alnn; DOCKET NBR:

050-302 RECIPIENT:

Reid,R.W.

No RO 6 A 4 ACCESSION NBR:7810110097 ORIGINATOR: "*ewart,W.P.

COPIES RECEIVED:

LTR 3 ENCL 0

SUBJECT:

SIZE:

9 nriginni chnranun cairnlatinnn fnv nuhj facil assnmod a wnrnt ramp struck rod.

BABW did not notify FPC of problem existing in other units.

  1. DISTRTPUTION Cones A001 DISTRTaVTIO* TITLES GrNERAL DTSTRIBUTION FOR AFTER ISSUANCE OF OPrRATING LICENSE, FOR ACTION NAME ENCL?

ce o,er

  • /7 ENCL f EG FT3 D W/ ENCL 1 On mv ror
  • / ENCL ORW#4 LA I & E L/P ENCL DELD I TR ONLY HANAUED W/FNCL CORE AFPFhk'A'CE hR k/ ENCL A0 CDD SYS 4 AROJ v/F*CL E NGINFF RI'.G HR
  • / ENCL REACTro SAFETY HR W/ ENCL PLANT SYSTEMS 44

'/ ENCL EEB

  • / ENCL EFFLifFNT TREAT SYS w/ ENCL J MCGniiGH w/ ENCL LPDR e:/.E N C L TERA h/ ENCL NS]C W/ ENCL ACRS h/16 ENCL total NU"RER OF COPIES REDblRED:

LTR 40 ENCL 39 1

k

~

g' NOTES:

8003160103 V

V

9

! th ?(; %

s e

oveQ>rsse, I@G G ICf40

%c; hep Ade-Florida f

W. P. STEW ART. DIR ECTOR POWER PRODUCTION c o a e o a a e in.

October 5,1978 Mr. R. W. Reid, Chief

~.

Operating Reactors Branch #4 Division of Operating Reactors U.S. Nuclear Regulatory Commission a

Washington, D.C. 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72

Dear Sir:

In December,1977, Babcock and Wilcox reviewed the shutdown margin calcula-tions for all B&W plants and discovered that a worst case stuck rod had not been assured in the calculations for several early plants. Crystal River Unit 3 was not one of these early plants. The original shutdown calcula-tions for CR3 had assumed a stuck rod; therefore, B&W did not notify FPC of the problem that existed in the other units.

This letter confirms that FPC is now aware of the problem and that the problem never existed at CR3.

If you have any questions, please contact us.

Since rely, FLORIDA POWER CORPORATION 1

.tL d G 4 k W. P. Stewart WPS/ldd s.

T05(10/3)

File:

3-B-7 General Office 3201 inirty fourin street soutn. P.O. Box 14042. St Petersburg. Florca 33733 813-866-5151

o 1

STATE OF FlJMIDA l

COUNTY OF PINELLAS W.P. Stewart states that he is the Director, Power Production, of Florida Power Corporation; that he is authorized on the part of

'said company to sign and file with the Nuclear Regulatory Commission the information attached hereto; and that all such

^

~

statements made and matters set forth therein are true and correct to the best of his knowledge, inf ormation and belief.

I g

c LV,

.kJ G M A W.P. Stewart Subscribed and sworn to before me, a Notary Public in and for the State and County above named, this 5th day of October,1978.

~$1 Notary Public [

Notary Public, State of Florida at Large, My Commission Expires: July 25, 1980 m

  • . w 4

k