LER-1977-097, /03L-0:on 771129,radiation Monitor Re 2006 Tripped Safety Features Actuation Sys Channel 3 Containment Radiation Due to Sporadic Spiking.Caused by Component Failure in Radiation Detector.Detector Replaced |
| Event date: |
|
|---|
| Report date: |
|
|---|
| 3461977097R03 - NRC Website |
|
text
_
'7'
- LICENSEE EVENT REPORT CONTROL BLOCK: l l
l l
l l
(PLEASE PRINT OR TYP!'
L REQUIRED INFORMATIONI t
1 6
@l150 l0 l-l 0 l0 lN l P lF l-l0 l 3 l@l4 l1 l1 l1 l1 l@l l
l@
i 0 H D B S 1 uCENSE NUMMER 25 28 UCENSE TYPE JO SI CAT $$
V UCENSEE CooE 14 COf 3o,"c l L @l 0 l 5 l 0 l-l0 l 3 l 4 l 6 @l1 11 l 2 l 91717 l@l 1l 2l ll 61 7) 7l@
" 7 o S 6d 69 EVENT oATE 74 75 REPORT oATE 80 i
8 60 61 oOCKET NUMBER EVENT OESCRIPTION AND PROS ABLE CONSEQUENCES h Io i2l l On 11/29 /77 at 1650 hours0.0191 days <br />0.458 hours <br />0.00273 weeks <br />6.27825e-4 months <br />, Radiation Monitor RE 2006 trinned SFAs chnnnal
't enne,4n-I l o t a l Iment Radiation due to sporadic spiking. The channel was then declared inoperable and l Io 64l lleft in the tripped state. This placed the unit in the Action Statement of Technical l I o l s t I pecification 3.3.2.1.
There was no danger to the health and safety of the public or !
S Ioisl l unit personnel. No other systems besides SFAS Channel 3 Containment Radiation were I
l o 17 l laffected except that it was then a one out of three trip.
Plant operation was not l
laffected by the component failure.
(NF-33-77-97)
I
,o,3; a0 SusCEo'E SEfaE
Sc'sCEE.
COMPONENT CooE Co lI lB l@ l 3l@ l Al@ l Il Nl S l Tl Rl Ul@ g@ lZ l@
lol9l 7
8 9
to 11 12 13 18 19 20 SEoUENTIAL OCCURRENCE REPORT REVISION LE R/Ro EVENT YEAR REPORT No.
CooE TYPE No.
h afg l217l7l l-l l 0l 9l 7l l/l l0l3l l Ll l-l l0l 22 23 24 26 27 28 29 30 31 32 yu T
N AC oP T
METH HoVR$
S8 I FoR S.
SLP L E MANUFAC RER C gl34Z lg l35Z l@ l Z l@
l 0l 0l 0l 0l l Yl@
lY]@
lXl@
lVl1l1l5l@
36 37 do di 4a 43 44 47 33 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS
- o;lThe apparent cause was a component failure in Radiation Detector, Victoreen Model I
l3 g,,,il Number 847-1.
The complete detector, Victoreen Model Number 847-1. was replaced and I
g goperability verified at 1905 hours0.022 days <br />0.529 hours <br />0.00315 weeks <br />7.248525e-4 months <br /> on December 2, 1977.
l t i t 31 1 I
11 tal I SO 7
d 9
%' POWER oTHER STATUS oIS RY elSCoVERY oESCRIPT1oN ST T NA l
l A l@l NA l
Ii (E I l Elg l 0 l 4 l 1lgl 7
8 1
12 11 44 45 46 60 RELEASED oF RELEASE AMouNToF ACTIVITY LOCATION oF RELEASE NA l
l NA l
1116 I lZ l @ W@l 1
8 9 10 11 44 45 80 PER$oNNEL EXPOSURES NU"SER TYPE oESCRIPTioN Ii i > I 10 l s l o l@l Zi@l NA i
,ER$oN~El'mu'4ES oESCRi,Tio~@
l NUM.ER li la l 101010 l@l NA 80 7
8 9 ti 12
==Eo sg>=P,= ~~~ @
8 o o e o 40637 c
i
- iz igi NA 30
? -
9 10 rrm IN f81 NA i
i i ! i i i i i i i i ! ! :,
ISSUE oE CRIPTIoN G8 69
?0 I J
a 3
?Q DVR 168-1 PHONE:
NAME OF PREPARER
TOLEDO EDISCN COMPANY DAVIS-BESSE UNIT ONE NUCLEAR POWER STATION s*
SUPPLEMENTAL INFOREATION FOR LER NP-33-77-97 l
DATE OF EVENT: November 29, 1977 FACILITY: Davis-Besse Unit 1 IDENTIFICATION OF OCCURRENCE: Failure of Radiation Monitor RE 2006 in Safety Features Actuation System (SFAS) Channel 3
(
Conditions Prior to Occurrence: The unit was in Mode 1, with Power (MWT) = 1153 and Load (MWE) = 389.
, Description of Occurrence: On November 29,1977, at 1650 hours0.0191 days <br />0.458 hours <br />0.00273 weeks <br />6.27825e-4 months <br /> Radiation Monitor RE 2006 tripped SFAS Channel 3 Containment Radiation due to sporadic spiking.
This The channel was then declared inoperable and left in the tripped state.
placed the unit in the Action Statement of Technical Specification 3.3.2.1 which requires all four Containment Radiation Monitors in all modes.
Designation of Apparent Cause of Occurrence: The apparent cause was.a component failure in Radiation Detector, Victoreen Model Number 847-1.
Analysis of Occurrence: There was no danger to the health and safety of the public or to unit personnel. No other systems besides SFAS Channel 3 Containment Radia-tion were affected except that it was then a one out of three trip. Plant opera-tion was not affected by the component failure.
4
Corrective Action
On November 30, 1977 at 1730 hours0.02 days <br />0.481 hours <br />0.00286 weeks <br />6.58265e-4 months <br />, corrective action com-menced on RE 2006 with the aid of the Victoreen representative.
From testing it was decided to change the complete detector, Victoreen Model Number 847-1.
ST 5031.01, "SFAS Monthly Test" was completed'on December 2, 1977, at 1905 hours0.022 days <br />0.529 hours <br />0.00315 weeks <br />7.248525e-4 months <br /> which verified operability, thus removing the unit from the Action Statement of Technical Specification 3.3.2.1.
The defective detector was given to the Victoreen representative for further analysis by Victoreen.
Failure Data: Two previous incidents of sporadic spiking on SFAS Channel 3 Containment Radiation occurred on October 24, 1977 (NF-33-77-87) and November 7, 1977 (NP-33-77-91).
w ew
,-e-r---
r
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000289/LER-1977-016-01, /01T-0:on 770924,RCS Temp & Pressure Rose.Caused by Half Trip Condition from Steam & Feedwater Rupture Control Sys.Possible Cause of Half Trip Attributed to Loose Connection at Terminal Boards | /01T-0:on 770924,RCS Temp & Pressure Rose.Caused by Half Trip Condition from Steam & Feedwater Rupture Control Sys.Possible Cause of Half Trip Attributed to Loose Connection at Terminal Boards | | | 05000289/LER-1977-016, Forwards Supplemental Info to LER 77-016/01T-0 Re Half Trip in Steam Feedwater Rupture Control Sys | Forwards Supplemental Info to LER 77-016/01T-0 Re Half Trip in Steam Feedwater Rupture Control Sys | | | 05000320/LER-1977-016, /01T-0 on 770924:half Trip of Steam & Feedwater Rupture Control Sys Resulted in Opening of Pressurizer Power Relief Valve.Possibly Caused by Loose Connections at Terminal Boards | /01T-0 on 770924:half Trip of Steam & Feedwater Rupture Control Sys Resulted in Opening of Pressurizer Power Relief Valve.Possibly Caused by Loose Connections at Terminal Boards | | | 05000346/LER-1977-017, Forwards LER 77-017/01T-0 | Forwards LER 77-017/01T-0 | | | 05000346/LER-1977-017-01, /01T-0:on 771020,both Auxiliary Feed Pump Suctions Lined Up to Deaerator Storage Tanks W/O Cooling Water Supply Shifting to Svc Water,Resulting in Water Greater than 200 F as Cooling Water for Auxiliary Feed Pump Bearings | /01T-0:on 771020,both Auxiliary Feed Pump Suctions Lined Up to Deaerator Storage Tanks W/O Cooling Water Supply Shifting to Svc Water,Resulting in Water Greater than 200 F as Cooling Water for Auxiliary Feed Pump Bearings | | | 05000346/LER-1977-018, Forwards LER 77-018/01T-0 | Forwards LER 77-018/01T-0 | | | 05000346/LER-1977-018-01, /01T-0:on 771108,station Review Board Found Auxiliary Feed Pump Turbine Governor Valve Vibrational Closure Design Deficiency.Caused by Lack of Force to Hold Valve Open.Requests Design Mod for Pump Turbines | /01T-0:on 771108,station Review Board Found Auxiliary Feed Pump Turbine Governor Valve Vibrational Closure Design Deficiency.Caused by Lack of Force to Hold Valve Open.Requests Design Mod for Pump Turbines | | | 05000346/LER-1977-019-01, /01T-0:on 771117,auxiliary Feedwater Valves AF 599 & AF 608 Found Closed,Rendering Steam & Feedwater Rupture Control Sys Pressure Switch Inputs Inoperable.Caused by Procedural Deficiency.Tests Revised | /01T-0:on 771117,auxiliary Feedwater Valves AF 599 & AF 608 Found Closed,Rendering Steam & Feedwater Rupture Control Sys Pressure Switch Inputs Inoperable.Caused by Procedural Deficiency.Tests Revised | | | 05000346/LER-1977-019, Forwards LER 77-019/01T-0 | Forwards LER 77-019/01T-0 | | | 05000346/LER-1977-077-03, /03L-0:on 771010,decay Heat Valve Pit Cover Removed to Inspect Decay Heat Isolation Valves DH11 & DH12 & to Perform Wiring Change on DH12.Insp Required for Leakage & Preventive Maint | /03L-0:on 771010,decay Heat Valve Pit Cover Removed to Inspect Decay Heat Isolation Valves DH11 & DH12 & to Perform Wiring Change on DH12.Insp Required for Leakage & Preventive Maint | | | 05000346/LER-1977-077, Forwards LER 77-077/03L-0 | Forwards LER 77-077/03L-0 | | | 05000346/LER-1977-078-03, /03L-0:on 771011,during Functional Test,Reactor Protection Sys Channel 1 Accidentally de-energized.Caused by Error in Maint Work Order.Personnel Instructed | /03L-0:on 771011,during Functional Test,Reactor Protection Sys Channel 1 Accidentally de-energized.Caused by Error in Maint Work Order.Personnel Instructed | | | 05000346/LER-1977-078, Forwards LER 77-078/03L-0 | Forwards LER 77-078/03L-0 | | | 05000346/LER-1977-079-03, /03L-0:on 771011,source Range Defector NI-1 Indication Failed Low Twice,Then Returned to Normal Operation by Itself.Cause Unknown | /03L-0:on 771011,source Range Defector NI-1 Indication Failed Low Twice,Then Returned to Normal Operation by Itself.Cause Unknown | | | 05000346/LER-1977-079, Forwards LER 77-079/03L-0 | Forwards LER 77-079/03L-0 | | | 05000346/LER-1977-080, Forwards LER 77-080/03L-0 | Forwards LER 77-080/03L-0 | | | 05000346/LER-1977-080-03, /03L-0:on 771016,governor Valve on Auxiliary Feed Pump 1-2 Found Closed During Auxiliary Feedwater Sys Monthly Test Performance.Caused by Possible Design Deficiency. Excessive Vibration Under Investigation by Maint Personnel | /03L-0:on 771016,governor Valve on Auxiliary Feed Pump 1-2 Found Closed During Auxiliary Feedwater Sys Monthly Test Performance.Caused by Possible Design Deficiency. Excessive Vibration Under Investigation by Maint Personnel | | | 05000346/LER-1977-081, Forwards LER 77-081/03L-0 | Forwards LER 77-081/03L-0 | | | 05000346/LER-1977-081-03, /03L-0:on 771018,during Miscellaneous Instrument Shift Checks,Containment to Annulus Differential Pressure Exceeded Water Gauge Tech Spec Limit.Caused by Procedure & Personnel Error.Startup Procedure Modified | /03L-0:on 771018,during Miscellaneous Instrument Shift Checks,Containment to Annulus Differential Pressure Exceeded Water Gauge Tech Spec Limit.Caused by Procedure & Personnel Error.Startup Procedure Modified | | | 05000346/LER-1977-082-03, /03L-0:on 771019,discharge & Recirculation Dampers of Emergency Ventilation Sys 2 Failed to Open When Fan Started.Caused by Loose & Dirty Controller Contacts.Module Removed & Reinserted, & Contacts Cleaned | /03L-0:on 771019,discharge & Recirculation Dampers of Emergency Ventilation Sys 2 Failed to Open When Fan Started.Caused by Loose & Dirty Controller Contacts.Module Removed & Reinserted, & Contacts Cleaned | | | 05000346/LER-1977-082, Forwards LER 77-082/03L-0 | Forwards LER 77-082/03L-0 | | | 05000346/LER-1977-083, Forwards LER 77-083/03L-0 | Forwards LER 77-083/03L-0 | | | 05000346/LER-1977-083-03, /03L-0:on 771025,stop Valve AF3872 Failed to Stroke When Given Open Signal.Caused by Component Failure. Torque Switch Replaced on 771027 | /03L-0:on 771025,stop Valve AF3872 Failed to Stroke When Given Open Signal.Caused by Component Failure. Torque Switch Replaced on 771027 | | | 05000346/LER-1977-084, Forwards LER 77-084/03L-0 | Forwards LER 77-084/03L-0 | | | 05000346/LER-1977-084-03, /03L-0:on 771025,surveillance Test ST 5080.01 Not Performed.Caused by Personnel Error.Test Performed Immediately & Computer Program Revised | /03L-0:on 771025,surveillance Test ST 5080.01 Not Performed.Caused by Personnel Error.Test Performed Immediately & Computer Program Revised | | | 05000346/LER-1977-086-03, /03L-0:on 771028,safety Features Actuation Sys Channel 4 Radiation Monitor RIS 2007 Failed to Respond to Internal Check Source.Caused by Component Failure.Low Amplifier Board Replaced & Monitor Recalibr | /03L-0:on 771028,safety Features Actuation Sys Channel 4 Radiation Monitor RIS 2007 Failed to Respond to Internal Check Source.Caused by Component Failure.Low Amplifier Board Replaced & Monitor Recalibr | | | 05000346/LER-1977-086, Forwards LER 77-086/03L-0 | Forwards LER 77-086/03L-0 | | | 05000346/LER-1977-087, Forwards LER 77-087/03L-0 | Forwards LER 77-087/03L-0 | | | 05000346/LER-1977-087-03, /03L-0:on 771024,safety Features Actuation Sys Channel 3 Containment Radiation Reaqdings Unreliable . Caused by Design/Fabrication Error.Facility Change Request 77-437 Issued for Permanent Repair | /03L-0:on 771024,safety Features Actuation Sys Channel 3 Containment Radiation Reaqdings Unreliable . Caused by Design/Fabrication Error.Facility Change Request 77-437 Issued for Permanent Repair | | | 05000346/LER-1977-088, Forwards LER 77-088/03L-0 | Forwards LER 77-088/03L-0 | | | 05000346/LER-1977-088-03, /03L-0:on 771027,source Range Detector NI-1 Indication Failed Low.Cause Unknown.Updated Rept Forthcoming | /03L-0:on 771027,source Range Detector NI-1 Indication Failed Low.Cause Unknown.Updated Rept Forthcoming | | | 05000346/LER-1977-089-03, /03L-1:on 771107,radiation Monitor RIS 2007 Was Showing Erratic Readings.Caused by Victoreen Low Range Amplifier Board 847-1-20 Failure.Board Replaced | /03L-1:on 771107,radiation Monitor RIS 2007 Was Showing Erratic Readings.Caused by Victoreen Low Range Amplifier Board 847-1-20 Failure.Board Replaced | | | 05000346/LER-1977-089, Forwards LER 77-089/03L-1.W/o Encl | Forwards LER 77-089/03L-1.W/o Encl | | | 05000346/LER-1977-090-03, /03L-0:on 771107,during Review of Deficiency in Steam & Feedwater Rupture Control Sys Monthly Test,Reactor Coolant Pump Found Inoperable.Caused by Component Failure. Voltage Regulating Diode Replaced | /03L-0:on 771107,during Review of Deficiency in Steam & Feedwater Rupture Control Sys Monthly Test,Reactor Coolant Pump Found Inoperable.Caused by Component Failure. Voltage Regulating Diode Replaced | | | 05000346/LER-1977-090, Forwards LER 77-090/03L-0 | Forwards LER 77-090/03L-0 | | | 05000346/LER-1977-091-03, /03L-0:on 771107,containment Radiation Monitor RIS 2006 Spiked & Reset Twice Causing Safety Features Actuation Sys Incident Level 1 Trips.Caused by Design Error | /03L-0:on 771107,containment Radiation Monitor RIS 2006 Spiked & Reset Twice Causing Safety Features Actuation Sys Incident Level 1 Trips.Caused by Design Error | | | 05000346/LER-1977-091, Forwards LER 77-091/03L-0 | Forwards LER 77-091/03L-0 | | | 05000346/LER-1977-092, Forwards LER 77-092/03L-0 | Forwards LER 77-092/03L-0 | | | 05000346/LER-1977-092-03, /03L-0:on 771101,facility Review Board Meeting Revealed That Surveillance Requirement of Venting Hpis Valve HP 72 Not Performed.Caused by Personnel Error.High Point Valve Vented & Modified | /03L-0:on 771101,facility Review Board Meeting Revealed That Surveillance Requirement of Venting Hpis Valve HP 72 Not Performed.Caused by Personnel Error.High Point Valve Vented & Modified | | | 05000346/LER-1977-093, Forwards LER 77-093/03L-0 | Forwards LER 77-093/03L-0 | | | 05000346/LER-1977-093-03, /03L-0:on 771114,reactor Protection Sys Daily Heat Balance Check Not Completed When Station Above 15% Rated Thermal Power During Oct-Nov 1977.Caused by Personnel Error. Surveillance Test Placed on Daily Testing Schedule | /03L-0:on 771114,reactor Protection Sys Daily Heat Balance Check Not Completed When Station Above 15% Rated Thermal Power During Oct-Nov 1977.Caused by Personnel Error. Surveillance Test Placed on Daily Testing Schedule | | | 05000346/LER-1977-094-03, /03L-0:on 771116,emergency Ventilation Sys Dampers Pdv 5014A & B Failed to Modulate Correctly to Draw Down Annulus.Caused by Defective Pressure Differential Controller.Dampers Replaced & Sys Retested | /03L-0:on 771116,emergency Ventilation Sys Dampers Pdv 5014A & B Failed to Modulate Correctly to Draw Down Annulus.Caused by Defective Pressure Differential Controller.Dampers Replaced & Sys Retested | | | 05000346/LER-1977-094, Forwards LER 77-094/03L-0 | Forwards LER 77-094/03L-0 | | | 05000346/LER-1977-095-03, /03L-0:on 771127,control Room Ventilation Isolation Damper HV 5311A Failed to Close on Radiation Monitor Trip.Caused by Component Failure.Damper Dismantled & Sealing Surfaces Cleaned & Lubricated | /03L-0:on 771127,control Room Ventilation Isolation Damper HV 5311A Failed to Close on Radiation Monitor Trip.Caused by Component Failure.Damper Dismantled & Sealing Surfaces Cleaned & Lubricated | | | 05000346/LER-1977-095, Forwards LER 77-095/03L-0 | Forwards LER 77-095/03L-0 | | | 05000346/LER-1977-097, Forwards LER 77-097/03L-0 | Forwards LER 77-097/03L-0 | | | 05000346/LER-1977-097-03, /03L-0:on 771129,radiation Monitor Re 2006 Tripped Safety Features Actuation Sys Channel 3 Containment Radiation Due to Sporadic Spiking.Caused by Component Failure in Radiation Detector.Detector Replaced | /03L-0:on 771129,radiation Monitor Re 2006 Tripped Safety Features Actuation Sys Channel 3 Containment Radiation Due to Sporadic Spiking.Caused by Component Failure in Radiation Detector.Detector Replaced | | | 05000346/LER-1977-100-03, /03L-0:on 771201 & 05,source Range Neutron Detector NI-1 Indication Dropped to Zero & Returned to Normal Operation W/O Assistance.Cause Unknown.After First Failure,Detector Replaced & Retested | /03L-0:on 771201 & 05,source Range Neutron Detector NI-1 Indication Dropped to Zero & Returned to Normal Operation W/O Assistance.Cause Unknown.After First Failure,Detector Replaced & Retested | | | 05000346/LER-1977-100, Forwards LER 77-100/03L-0 | Forwards LER 77-100/03L-0 | | | 05000346/LER-1977-101-03, /03L-0:on 771201,diesel Generator 1-1 Inoperable Due to Failure to Perform Required Surveillance Testing on Diesel Generator 1-2 within Required Tech Spec Interval. Caused by Personnel Error | /03L-0:on 771201,diesel Generator 1-1 Inoperable Due to Failure to Perform Required Surveillance Testing on Diesel Generator 1-2 within Required Tech Spec Interval. Caused by Personnel Error | |
|