ML19326A428

From kanterella
Jump to navigation Jump to search
Forwards Inquiry Rept 50-346/72-01
ML19326A428
Person / Time
Site: Davis Besse 
Issue date: 07/20/1972
From: Vetter W
US ATOMIC ENERGY COMMISSION (AEC)
To: Henderson J
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19326A423 List:
References
NUDOCS 8002030235
Download: ML19326A428 (1)


Text

O

~

UNITED STATES h

f.

i ATOMIC ENERGY COMMISSION I

DIVISION OF COMPLIANCE REGION lll 799 ROOSEVELT ROAD Tet

  • GLEN ELLYN, ILLINOls 60137 (312) ass-zeoo July 20, 1972 J. B. Henderson, Chief, Reactor Construction Branch Directorate of Regulatory Operations, Headquarters TOLEDO EDISON COMPANY LICENSE NO. CPPR-80 i

DAVIS-BESSE ACCIDENTAL DAMAGE TO PUMP VOLUTE NO. 701N0241 The attached report of an inquiry from the subject licensee is transmitted for information. The volute, identified in the attached inquiry report by serial number, is for one of the plant primary coolant pumps.

The licensee was informed that the incident is considered to be fully reportable in keeping with the requirements of 10 CFR Part 50.55(e) and our impression is that the 30-day requirement will be accomplished on schedule.

W. E. Vetter, Chief Reactor Construction Branch

Attachment:

RO Inquiry. Rpt No. 050-346/72-01 (2 cys) j cc:

R. B. Monigue, RS (3)

R. S. Boyd, L (2)

R. C. DeYoung, L (2)

D. J. Skovholt, L (3)

H. R. Denton, L (2)

G. W. Rainmuth, R0 H. D. Thornburg, R0 R. H. Engelken, R0 R0 Files DR Central Files C

8002030 %

O'

-