05000346/LER-1978-078-03, /03L-0:on 780713,ST 5099.08 & ST 5099.11 Not Performed Per Tech Spec 4.0.5 & Not Included in Computer Schedule.St 5099.08 Incorporated in Test Program on 780727. Passive Valves Identified & Operational Log Used

From kanterella
(Redirected from ML19326A121)
Jump to navigation Jump to search
/03L-0:on 780713,ST 5099.08 & ST 5099.11 Not Performed Per Tech Spec 4.0.5 & Not Included in Computer Schedule.St 5099.08 Incorporated in Test Program on 780727. Passive Valves Identified & Operational Log Used
ML19326A121
Person / Time
Site: Davis Besse 
Issue date: 08/08/1978
From: George T
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19326A116 List:
References
LER-78-078-03L-0, LER-78-78-3L, NUDOCS 8001310678
Download: ML19326A121 (2)


LER-1978-078, /03L-0:on 780713,ST 5099.08 & ST 5099.11 Not Performed Per Tech Spec 4.0.5 & Not Included in Computer Schedule.St 5099.08 Incorporated in Test Program on 780727. Passive Valves Identified & Operational Log Used
Event date:
Report date:
3461978078R03 - NRC Website

text

U. S. NUCLEAH N ttauLea : Un i Lummsww.e NRC PORM 366 47 77)

LICENSEE EVENT REPORT (J^. -

CONTRCL BLCCK: l l

1 I

l l

l (PLEAsE PRINT OR TYPE ALL REQUIRED INFORMATION)

Sl1 glis0 l0 l-l 0 l0 lN lP lF l-l0 l3 l@l4 l1 l1 l1l1l@l l

l@

o 0lHlD B to uCENSE NUMBER 25 26 uCENSE TYPE 40 57 gar $d 7

9 LICENSEE CODE CCN'T lol3l sofy l L l@l 0 l 5 l 0 l-l 0 l 3 l 4l 6 @ l0 17 11 ]3 17 l8 @ l0 l8 l0 18 17 l8 l@

?

60 61 CoCKET NuM8 ER

'68 63 EV ENT QATE 14 75 REPORT CATE 30 EVENT DESCRIPTION AND PROB A8LE CCNSEQUENCES (1$)

10!2l 10n July 12,1978 at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />, it was discovered that Surveillance Tests ST 5099.08.

10 t a l 1 " Miscellaneous Valve Quarterly Test" and ST 5099.11. "Ocerational Checks of Passive l

There I 10 g., i, Valves" were not being performed as required by Technical Specification 4.0.5.

loIsi iwas no dange; to the health and safety of the public or to unit personnel.

I lo !s I 1 ST 509f.08 was performed on July 27 and passed tha acceptance criteria.

ST 5099.11 is(

to verify I

[ o l 7 l ] only used to record the times that a passiva valve is operated and is not i o t a i I any safety related operation.

CE-33-78-931 l

80 E

CCE Su C E COMPONENT Co0E SL oc'E SU E

I Z l Zl@ ID l@ l Zl@ I Z l z i Z i z l 2 II l@ IZ l@ IZ l @

10191 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION gg g, no EVENT YEA R REPORT No.

CooE TYPE No.

aEpo RT l7l8l l-l l 017 l 8l l/l 1013 l l Ll l-l l0 l

@ NUMBER

,_ 2 22 23 24 26 27 28 29 30 31 32 p)N*EN #"Eo*N

^5e*E"1"'E po" "S s.

""s'u"pDEE uaOu"I2CERER l 0 l 0 l 0 @l 0 l oI[p'tf!T

    • "eWo" i

4C s

E sours M

l Y l@

l Nl@

lZl@

l Z l Z l Z l Z l@

l Glgl34 l@

l Z l@

[ Z l@

V Z

33 05 06 37 40 el 42 43 44 47 CAUSE DESCRIPTION AND CCARECTIVE ACTIONS On l

oll These tests were never incorporated in the surveillance test scheduling program.

ii July 27, 1978, ST 5099.08 was incorporated in the computer schedule and was performed [

,,,,g satisfactorily. The passive valves in ST 5099.11 have been identified and the opera,

tional log for these passive valves is being used at the present ti=e.

[

,,,,, y I

t i 141 1 30 7

8 9 crwERsTArus @ 5isEc? E0v'

's'T2'u?

snowgR C

oiscovEnv cEsCRiartoN r

NA l

lCl@l Scheduling Personnel Inspection l

l1 l 5 I l Gl@ l 0 l 0 l 0 l@l i2 n

44 4s e

a0 A$nvtTv C$ TENT RELEASEo of RELEASE AMouNToF ACTIVITY LOCATION oF RELEASE NA l

l NA l

I1 le l l Zl @ l Z Ql 7

8 9 10 tt 44 45 SO PER$CNNEL Expo 5uR E3 NUMBER TY8E CESCRIPTtoN li l 71 1 01 01 0@l z l@l NA l

,ERsoNNE L,Nw'Rits oEsCRirTiCN@

l NuwER I

l l 0! of 01@l NA n

30 l

9 11 12 LOS,S OF oR cAMAct To #ACILITY g o 01 $1U' Tv E CEsCR,, Tion l

lZl@lNA 30 7

s 9 to

'O'L' CITY NRC USE CNLY

'SSUED CESCRIPTioN [d,o_llNl@lNA l

llllllllIIlIl*

68 69 30 3 7

8 9 to 419-259-5000, Ext. 251 {

DVR 78-123 PHONE:

NAME CF PREPARER

' 4.S ' '

TOLEDO EDISON COMPANf s

DAVIS-BESSE UNIT ONE NUCLEAR POWER STATION.

SUPPLEMENTAL INFORMATION FOR LER NP-33-78-93 DATE OF OCCURRENCE: July 13, 1978 FACILITY: Davis-Besse Unit 1 IDENTIFICATION OF OCCURRENCE: Failure to perform ST 5099.08, " Miscellaneous Valves Quarterly Test", and ST 5099.11, " Operational Checks of Passive Valves" Conditions Prior to Occurrence: The unit was in Mode 5, with Power (MWT) = 0, and Load (MWE) = 0.

Description of Occurrence: On July 12, 1978, at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />, it was discovered that Surveillance Tests, ST 5099.08, " Miscellaneous Valve Quarterly Test", and ST 5099.11, " Operational Checks of Passive Valves" were not being performed as required by Technical Specification 4.0.3.

This occurrence was discovered by surveillance test scheduling personnel while verifying that all surveillance tests are included in the scheduling program.

Since both of these tests were not required until January 1, 1978, ST 5099.08 should have been performed twice and ST 5099.11 should have been performed each time a passive valve was operated.

O Designation of Apuarent Cause of Occurrence: These tests were never incorporated in the surveillance test scheduling program, and therefore were not included in the computer schedule and the required test lists.

Analysis of Occurrence: There was no danger to the health and safety of the public j

or to unit personnel. Surveillance Test ST 5099.08 was performed on July 27, 1978 and passed the acceptance criteria. Therefore, we believe that the valves were operable' over the time period that the surveillance test was not perfor=ed.

Sur-veillance Test ST 5099.11 is only used to record the times that a passive valve is operated and is not to verify any safety related operation.

l

Corrective Action

On July 27,1978, ST 5099.08 was incorporated in the computer schedule and was performed satisfactorily. The passive valves in ST 5099.11 have been identified and the operational log for these passive valves is being used at the present time.

Failure Data: There have been no 'srevious similar occurrences.

LER #78-078

\\/

w/

i l