Responds to 890907 Request for Addl Info for Closeout of IE Bulletin 79-15 Re Containment Spray Pumps.Type & Application of Pumps Described
ML19325F418
Person / Time
Site: Maine Yankee
Issue date: 11/14/1989
From: Whittier G
Maine Yankee
To: Wessman R
Office of Nuclear Reactor Regulation
References
GDW-89-365, IEB-79-15, MN-89-141, NUDOCS 8911210272
Download: ML19325F418 (6)


Text

.

o

>y MaineYankee

.. _.emm._...,

EDISON DRIVE

  • AUGUSTA. M AINE 043M e (207) 6224668 l

)

l

)

November 14, 1989 MN-89-141 GDW-89-365 l

t i

Director of Nuclear Reactor Regulation bNITED STATES NUCLEAR REGULATORY COMMISSION l

Washington, DC 20555 j

Attention: Mr. Richard H. Wessman, Division of Reactor Projects 1-3

References:

(a)

License No. DPR-36 (Docket No. 50-309)

(b)

USNRC Letter to Maine Yankee dated September 7, 1989 - Request for Additional Information for Closeout of IE Bulletin 79-15 (c)

USNRC Letter to Maine Yankee dated July 11,1979, IE Bulletin No. 79-15 Deep Draft Pump l

Deficiencies (d)

Maine Yankee Letter to USNRC dated September 11,1979 (WMY-79-92), Response to IE Bulletin No. 79-15

\\.

Subject:

Response to Request for Additional Information - Containment Spray Pumps - for Closeout of IE Bulletin No. 79-15 Gentlemen:

[

Maine Yankee was requested, by Reference (b), to provide additional information, for USNRC review, to enable closeout of MRC IE Bulletin No.

i 79-15.

The following information is enclosed:

l r

- Type and Application of Pumps

- Detailed Maintenance History g

The followir.g information has been provided directly to Maine Yankee's NRR Project Manager, Mr. Eric J. Leeds:

i L

p

- Drawings, Sectional Assemblies and Parts Lists

- Applicable P & ids t

- Recent Testing Requirements, Procedures, and Results t

I i

i GDW89365.LTR g422;ggg;;gg;4ggo9

,f)

L Poc 1

7--

i e.

.o..

t UNITED STATES NUCLEAR REGULATORY COMMISSION MN-89-141 i

Attention: Mr. Richard H. Wessman Page two This supplements information previously provided in Reference (d). Should you have any questions on this information, please cont.sct us.

Very truly yours, r

MMN G. D. Whittier, Manager Nuclear Engineering and Licensing RCC:WSD Enclosures c:

. Document Control Desk %

Mr. Eric J. Leeds Mr. William T. Russell Mr. Cornelius F. Holden l

l p

I l

1 GDW89365.LTR 1

l-

c 3

i ENCLOSURE 1 j

TYPE AND APPLICATION OF PLMPS i

Containment Spray Pumps P-61A, 8, and S j

Manufacturer:

Byron Jackson Model No.:

18 CKXH-2STG VMT l

Capacity:

3700 GPM at 305 ft TDH Dimensions:

Height 36 ft 5-5/8 in.

Diameter 28 in.

Application:

Described in Section 6.3 of the Maine Yankee Final Safety Analysis Report GDW89365.LTR l

e i

l 1

ENCLOSURE 2 i

DETAILfD MAINTENANCE HIS10R1 P-61A:

l 3/19/73 MR 493-73 Sealing line to the gland area leaks at the connection union.

Tightened unions, leak stopp d.

3/4/74 MR 219-74 Repaired mechanical seal leak-off line leaks.

l 9/27/77 MR1513-77 Small leak in leak-off gland area. Replaced leaking pipe union assembly with 1500 lb. safety class stainless tubing assembly using crimp fittings.

System pressure tested by Operations. System is leak tight.

5/15/86 DR6184-85 P-61A has an excessive packing leak. Installed new mechanical seal internals.

Replaced the following internals: Stationary face, rotating face, "0" ring, mechanical seal seat gasket, bellows adapter gasket, sleeve gasket, and flange gasket. Pump shaft run out and checked (0.004 T.I.R), Pump impeller lift set to 1/4".

Per factory rep., the bellows assembly had to be heated to 400 degrees F for installation of rotating face.

It was allowed to cool slowly.

Final dial indicator readings taken with the dial indicator mounted on the motor shaft to the inside of the stuffing box of the

pump, t

Per telecon with Byron Jackson Field

Services, misalignment of 2 1/4 thousandths is acceptabia.

P-61A standing water in casing - drain plu 6/16/87 DR3634-87 Unplug drain casing. Remove debris, clean up. gged up.

7/16/87 DR4433-87 The cap located on the lower part of the seal housing has a steady dripping leak.

Pipe cap removed, threads cleaned and inspected, new sealant applied and cap reinstalled.

5/9/88 DR1112-88 Gland ' leakage on P-61A. No leakage without pump running.

Replaced obsolete seal with replacement model (per print 187393-1-01) under component substitution.

10/5/88 DR3354-88 P-61A has gland leaking.

The pump was found dry after o

test surveillance. If pump is leaking it is not through seal.

GDW89365.LTR

.s

. )

l j

n ENCLOSURE 2 DETAILED MAINTENANCE HISTORY (continued)

P-618:

I 2/6/74 MR 219-74 Repaired mechanical seal leak-off line leaks.

12/27/73 MR2147-73 Tightened up pipeplugs, leak stopped.

l 4/4/77 MR 454-77 Removed and replaced mechanical seal cooling coil vent n

valve with new one.

Replaced with 1/2" Whitey valve.

SS 12NBSB.

9/27/77 MR1513-77 Small leak in gland area. Replaced leaking pipe union assembly with 1500 lb. rateo Safety Class I stainless i

steel tubing assembly using crimp fittings. System pressure tested by Operations.

System is leak tight.

10/30/79 MR1250-79 P-61B damaged by extended operation without flow.

Removed, disassembled, and inspected pump to determine i

damage. Removed motor, mechanical seal, pump shafts and impe11ers. Measure all critical fits. Cleaned all fits and ordered all necessary replacement parts.

Placed shal. sections between centers and checked for bent shafts.

Found one to be 0.011" out of alignment.

Straightened bent shaft.

All shafts are now within 0.002".

3/26/81 MR1699-80 Reassemble P-61B ref. MR1250-79.

Reassembled pump I

according to Maintenance procedure MYM-5-45. Installed new mechanical seal, throttle bushings, all new shaft

~,

sleeves and carbon bearings, new upper shaft wear ring on eye impeller and wear ring or. lower impellor, 4/22/82 MR 843-82 Seal is leaking. Checked out seal and found minor leakage. Seal leakage determined not to be sufficient enough to replace seal or cause concern.

6/16/87 DR3638-87 Glar.d has a lot of boron build-up on it. Deborate and clean up. Repair leak, Cleaned pump in the gland area.

Tightened swedgloc fittings.

2 8/14/87 DR5226-87 Gland has a lot of boron build-up, does not appear to i

be leaking when pump is not running Cleaned boron and observed no obvious damage.

10/5/88 DR2319-88 Boron leak seal cooler pipe fitting. Tubing fittings are leaking at mechanical seal area. Tightened fitting and there was no apparent leak.

GDW89365.LTR

6^

[ ('-

ENCLOSURE 2 l

DETAILED MAINTENANCE HISTORY (continued) i P-61$

i 3/4/74 MR 219-74 Repaired mechanical seal leak-off line leaks.

j 4/4/77 MR 454-77 Mechanical seal cooling coil vent valve is leaking, j

Removed existing 1/2" stainless steel llhitey valve and replaced with new one No. SS-12858.

9/27/77 MR1513-77 Small leak in gland area. Replaced leaking pipe union assembly with a 1500 lb. rated safety class 1-1/2" stainless steel tubing assembly using crimped fittings, i

System was pressure tested by Operations. System is leak j

tight.

6/14/88 DR2579-88 P-61S seal is leaking. Tubing fittings are leaking at

}

mechanical seal area.

i i

i r

t i

i i

l l

G0W89365.LTR l'

I

~

9 e

1, l

ENCLOSURE 2 i

DETAILED MAINTENANCE HISTORY (continued)

P-615:

s 3/4/74 MR 219-74 Repaired mechanical seal leak-off line leaks.

?

4/4/77 MR 454-77 Mechanical seal cooling coil vent valve is leaking.

Removed existing 1/2" stainless steel Whitey valve and replaced with new one No. SS-12858.

9/27/77 MR1513-77 Small leak in gland area. Replaced leaking pipe union assembly with a 1500 lb. rated safety class 1-1/2" stainless steel tubing assembly using crimped fittings.

System was pressure tested by Operations. System is leak tight.

6/14/88 DR2579-88 P-615 seal is leaking. Tubing fittings are leaking at mechanical seal area.

I i

L l

l l