ML19325D284
| ML19325D284 | |
| Person / Time | |
|---|---|
| Site: | Fort Calhoun |
| Issue date: | 10/16/1989 |
| From: | Morris K OMAHA PUBLIC POWER DISTRICT |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| LIC-89-952, NUDOCS 8910230009 | |
| Download: ML19325D284 (1) | |
Text
__
,,.s Omaha Public Power District 1623 Harney Omaha Nebraska 68102 2247 402/536 4000 October 16, 1989 LIC-89-952 l
l l
U. S. Nuclear Regulatory Commission i
Attn: Document Control Desk Mail Station P1-137 Washington, DC 20555
Reference:
Docket No. 50-285 Gentlemen:
)
SUBJECT:
Annual Report on Loss of Coolant Accident (LOCA)/ Emergency Core Cooling System (ECCS)
As required in 10CFR50.46(a)(3)(ii), Omaha Public Power District (OPPD) has reviewed the LOCA/ECCS Codes and Methods for changes or errors as applied to the Fort Calhoun Nuclear Station (FCS) Unit No.1.
This review was completed by Combustion Engineering. The only change or error through December 1988 was in the STRIKIN-II computer code. The magnitude of this change and error was less than l'F in the peak clad temperature as described in the " Annual Report on C-E ECCS Codes and Methods for 10CFR50.46."
i Combustion Engineering reviews the LOCA/LCCS analyses for FCS on an annual basis with the report being issued during the first quarter of the following year. Therefore, beginning in 1990, OPPD will submit the LOCA/ECCS changes and i
if necessary, identified errors, as required by 10CFR50.46(a)(3), within 90 days from receipt of the C-E report.
If you should have any questions, please contact me.
Sincerely,
/
MY orris Division Manager Nuclear Operations KJM/pjc 1
c:
LeBoeuf, Lamb, Leiby & MacRae Aed R. D. Martin, NRC Regional Administrator i
A. Bournia, NRC Project Manager P. H. Harrell, NRC Senior Resident Inspector 8910230009 891016 POR ADOCK 05000283 P
FDC I
as wa impioumengm tagopponunnu
--.