framatome, November 19, 2019 NRC:19:030 U.S. Nuclear Regulatory Commission Document Control Desk

  • 11555 Rockville Pike Rockville, MD 20852.

10 CFR 60.46 Annual Report for the U.S. EPR Design Certification Ref. 1:

Letter, Sandra M. Sloan (AREVA NP Inc.) to Document Control Desk (NRC),

"Application for Standard Design Certification of the U.S. EPR (Project No. 733),"

NRC:07:070, December 11, 2007.

Ref. 2:

Letter, Getachew Tesfaye (NRC) to Sandra M. Sloan (AREVA NP Inc.), "AREVA NP Inc. - Acceptance of the Application for Standard Design Certification of the U.S.

EPR," February 25, 2008.

Ref. 3:

Letter, Gary Peters (Framatome Inc.) to Document Control Desk (NRC), "10 CFR 50.46 Annual Report for the U.S. EPR Design Certification," NRC:18:042, November 30, 2018.

Framatome Inc. (Framatome) submitted the application for a Standard Design Certification of the U.S. EPR design* in Reference 1. The NRC accepted lhe application for review in.

Reference 2. In accordance with 10 CFR 50.46, "Acceptance Criteria for Emergency Core Cooling Systems for Light Water Reactors," Framatom*e is submitting this annual report of the emergency core cooling system (ECCS) evaluation model changes and errors for the U.S. EPR

  • Standard Design (Docket 52-020). The previous annual report was submitted in Reference 3.
  • This report addresses two evaluation models: one for_ the large break loss of coolant accident' (LBLOCA), and one for the small break loss of coolant accident (SBLOCA). The summary of the changes and error corrections made between October 1, 2018 an'd September 30, 2019 for the LBLOCA evaluation model is provided in Attachment A. The summary of the changes and error corrections made between October 1_, 2018 and September 30, 2019 for the SBLOCA evaluation model is provided in Attachment B.

Fra.matoma inc.

3315 Old Forest Road Lynchburg, VA 24501 Tel:(434)832-3000 www.framatoma.com

Document Control Desk November 19, 2019 NRC:19:030 Page2 If you have any questions related to this information, please contact Gayle Elliott, Deputy Director, Licensing & Regulatory Affairs, by telephone at (434) 832-3347, or by e-mail at Gayle.Elliott@framatome.com.

Sincerely,.

~?~

Gary Peters, Director Licensing & Regulatory Affairs

cc:

Docket 52-020

Document Control Des_k November 19, 2019 Attachment A:

Large Break Loss of Coolant Accident (LBLOCA) Evah,.iatlon Model A report of changes and errors in the LBLOCA evaluation mo,del for the period of NRC:19:030 Page A-1 October 1, 2018 to September 30, 2019 is presented below. The estimated effect on peak cladding temperature is summarized in Table A1.

1. An issue was identified with the implementation of the Cathcart-Pawer correlation for metal-water reaction (MWR). The correlation is used for the calculation of metal-water reaction in the U.S. EPR_Realistic Large Break LOCA (RLBLOCA) methodology.

Cathcart-Pawel provided a set of equations for the rate constants associated with the oxidation process 1. In the RLBLOCA methodology, the correlation fat the rate of oxide thickness was used instead of the correlation for tne rate of total oxygen consumed. The expected correlation based on the follow-on calculations in S-RELAP5 and the 10 CFR 50.46(b)(2) criterion is the total oxygen consumed correlation.

As compared to a total oxygen-based implementation, the use of the oxide-based implementation led to a more conservative prediction of the transient oxidation and heat released during the reaction. The additional heat from the reaction could have resulted in higher calculated values of the peak clad temperature (PCT). For LBLOCA though, the degree of differences between the two correlation implementations has a negligible impact on PCT. The LlPCT for the U.S. EPR RLBLOCA analysis is 0°F. Previously rep0rted change and error estimates are not impacted. The local oxidation and whole core hydrogen also remain _well within tne 1 O CFR 50.46 acceptance criteria with the correction. The U.S. EPR SBLOCA methodol09y uses the Baker-Just correlation and is not impacted by this error.

The LBLOCA evaluation model for. the U.S. EPR design is described in the topical report ANP-10278PA. The'primary computer code in the LBLOCA evaluation. r:nodel is S-RELAP5.

1 J.V. Cathcart, RE. Pawel, RA. McKee, RE. Druschel, G.J. Yurek,-J.J. Campbell, and S.H.

Jury, ORNUNUREG-17, Zirconium Metal-Water Oxidation Kinetics IV. Reaction Rate Studies, Published August 1977.

Document Control Desk Noyember 19, 2019 Table A1: LBLOCA Margin Summary Sheet -Annual Report Plant Name:

U.S. EPR Standard Design Certification A.

8.

Evalu~tion Model: RLBLOCA (ANP-10278PA)

Initial Peak Cladding Temperature (PCT)= 1780°F Prior 1 O CFR 50.46 Changes or Error Corrections -

previous Years Current 1 O CFR 50.46 Changes - This Report Error in the S-RELAP5 Cathcart-Pawel MWR Sum of 1 O CFR 50.46 Changes for this Reporting Period Estimate of PCT (_unchanged)

Net PCT Effect

.t.PCT =

+0°F

.t.PCT=

+0°F

.t.PCT=

+0°F

= 1780°F NRC:19:030 Pag~A-2 Absolute PCT Effect

+0°F

+0°F

+0°F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact for changes and errors identified since this analysis is less than 2200°F.

Document Control Desk November 19, 2019 Attachment B Small Break Loss of Coolant Accident (SBLOCA) Evaluation Model NRC:19:030 Page B-1 There were no.changes or errors reported in the-sBLOCA evaluation model for the period of October 1, 2018 to September 30, 2019. The estimated effect o*n peak cladding temperature is summarized in Table 81.

The SBLOCA evaluation model for the U.S. EPR design is described in the topical report ANP-10263PA and in the topical report EMF-2328PA. The primary computer code in the SBLOCA evaluation model is S-RE;LAPS.

Document Control Desk November 19, 2019 Plant Name:

Table 81: SBLOCA Margin Summary.Sheet -Annual Report U.S. EPR Standard Design Certification A

B.

Evaluation Model: SBLOCA (ANP-10263PA and EMF-2328PA)

Initial Peak Cladding Temperature'(PCT) = 1638°F Prior 1 O CFR '50.46 Changes or Error Corrections -

previous Years Current 10 CFR 50.46'Changes-: This Report (no changes or errors)

~stimate of PCT (unchanged)

Net PCT Effect LlPCT =

+2°F LlPCT =

+0°F

=

1640°F NRC:19*030 Page B-2 Absolute PCT Effect

+266°F

+0°F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact for changes and errors.identified since this analysis is less than 2200°F.

.