ML19323H647
| ML19323H647 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 06/09/1980 |
| From: | Mccolligan J SACRAMENTO MUNICIPAL UTILITY DISTRICT |
| To: | |
| References | |
| RJR-80-269, TAC-42850, NUDOCS 8006160010 | |
| Download: ML19323H647 (1) | |
Text
.
STRUD
~ '
SACRAMENTO MUNICIPAL UT'LITY DISTRICT C 6201 S Street, Box 15a30. Sacramento, California 95813; (916) 452 3211 RJR 80-269 June 9, 1980 Mr. R. H. Engelken, Director Region V Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 1990 North California Boulevard Walnut Creek Plaza, Suite 202 Walnut Creek, California 94396 Re: Operating License DPR-54 Docket No. 50-312 Reportable Occurrence 80-28
Dear Mr. Engelken:
Sacramento Municipal Utility District has determined that a reportable occurrence under Section C.2.a(8) requires prompt notification.
A re' view of the SFAS digital actuation system that requires energi:stion to trip reveals that under possible conditions where. inverter A or B is removed from service a single failure of the other inverter during an accident will prevent the Safety Features System from operating.
The immediate corrective action has been completed that requires
,,i treating the A and B inverters as safety features equipment.
If inverter A or B becomes inoperable, the reactor will be shut j
down if the inverter A or B is not returned to service within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.
This limit is within the limits established in the Technical Specificat'_ons safety features equipment.
A complete report will be forwarded to your office within 14 days.
Si'.cerely yours,
/
i
. V. McColligan
. Acting Mahager, Nuclear Operations
~
RWC:jr es: MIPC (2) 0 0'
s 80.061600lO S
l I