ML19323G636

From kanterella
Jump to navigation Jump to search
Forwards LER 80-041/03L-0
Date released: 12/03/2019 Download: ML19323G636


LER 80-041/03L-0:on 800503,during Review of Operations Periodic Test Schedule,Quarterly Inservice Insp of B Lhsi Pump Check Valves Determined Not Performed within Required Interval.Caused by Inadvertent Deletion from Schedule
ML19323G639
Person / Time
Site: North Anna Dominion icon.png
Issue date: 05/30/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323G639 (2)
Forwards LER 80-041/03L-0
ML19323G634
Person / Time
Site: North Anna Dominion icon.png
Issue date: 05/30/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323G634 (1)