ML19323F662

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 80-12, Valve-Shaft-To-Actuator Key May Fall Out of Place When Mounted Below Horizontal Axis. No Written Response Required
ML19323F662
Person / Time
Site: Limerick  
Issue date: 05/14/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
References
NUDOCS 8005290297
Download: ML19323F662 (1)


Text

UC

/

'o UNITED STATES 89 N

NUCLEAR REGULATORY COMMISSION c

j REGION I 631 PARK AVENUE

%, +....o' KING OF PRUSSIA, PENNSYLVANIA 19406 May 14, 1980 Docket Nos. 50-352 50-353 Philadelphia Electric Company ATTN:

Mr. John S. Kemper Vice President Engineering and Research 2301 Market Street Philadelphia, Pennsylvania 19101 Gentlemen:

The enclosed IE Circular No. 80-12, " Valve-Shaft-To-Actuator Key May Fall Out of Place When Mounted Below Horizontal Axis," is forwarded to you for infor-mation.

No written response is required.

If you desire additional infor-mation regarding this matter, please contact this office.

Sincerely, 8

oyce H. Grier Director

Enclosures:

1.

IE Circular No. 80-12 with Attachments 2.

List of Recent.y Issued IE Circulars CONTACT:

D. L. Caphton (215-337-5346) cc w/encls:

V. S. Boyer, Senior Vice President, Nuclear Power j

8005290297

ENCLOSURE 1 SSINS No.: 6830 UNITED STATES Accession No.:

NUCLEAR REGULATORY COMMISSION 8005050052 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Circular No. 80-12 Date:

May 14, 1980 Page 1 of 2 VALVE-SHAFT-TO-ACTUATOR KEY MAY FALL OUT OF PLACE WHEN MOUNTED BELOW HORIZONTAL AXIS Description of Circumstances:

Tennessee Valley Authority has identified and reported to the NRC a non-conformance on a Bettis Robot-Arm actuator installed on a Pratt butterfly valve at the Sequoyah nuclear plant.

It is reported (ref. attached 10 CFR 50.55(e) report) that a valve became inoperable when the valve-shaft-to-actuator key fell out of place.

It is further noted that the orientation of this valva assembly was such that the operator was on the bottom of the valve (below the horizontal axis).

The Pratt butterfly valve furnished with Bettis actuator is designed with a press-fit keyway connection valve / actuator. We believe other manufacturers' connections may be of similar construction and therefore subject to this failure mode.

On May 1, 1980, Pratt Company sent letters to their customers who have these connections (attached list).

They recoramended that their customers review their insta11at. ion of such connections, and if the keyway is oriented below horizontal, make one of the following field modifications:

1.

Add a spacer bushing, or shim plate to fill the void between the top of the shaft and the indicating plate en the actuator.

2.

Locally upset the end of the valve shaft in the area of the keyway using a hand punch in such a way that the key could not work loose.

3.

Install new keys of longer length which extend above the end of the valve shaft whereby the key is up to the actuator plate and could not slip down if inverted.

Recommended Action for Licensee Consideration:

We request that all plants make the connections similar to the above de DUPLICATE DOCUMENT not supplied by those particular ma are susceptible to failure, one of Entire document previously appropriate action should be taken entered into system under:

ANO OO b

No. of pages:

-