ML19323F158

From kanterella
Jump to navigation Jump to search
Forwards LER 80-034/03L-0
Date released: 12/03/2019 Download: ML19323F158


LER 80-034/03L-0:on 800420,relay Coil 16AK-27 Failed,Causing Closure of Reactor Water Cleanup Isolation Valves FCV-69-2 & FCV-69-12.Valve FCV-69-1 Failed to Close Due to Loose & Broken Wire.Relay Coil Failure Caused by Normal Aging
ML19323F165
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 05/19/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323F165 (2)
Forwards LER 80-034/03L-0
ML19323F157
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 05/19/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323F157 (1)