Forwards Rept, Ft Calhoun Cycle 6 Small Break ECCS Performance Evaluation at 1500MW, in Support of Application for Amend of DPR-40 Filed 790717
Date released: 12/03/2019 Download: ML19323F129


Ft Calhoun Cycle 6 Small Break ECCS Performance Evaluation at 1500MW.
ML19323F131
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 05/21/1980
From:
OMAHA PUBLIC POWER DISTRICT
To:
References
Download: ML19323F131 (43)
Forwards Rept, Ft Calhoun Cycle 6 Small Break ECCS Performance Evaluation at 1500MW, in Support of Application for Amend of DPR-40 Filed 790717
ML19323F128
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 05/21/1980
From: William Jones
OMAHA PUBLIC POWER DISTRICT
To: CLARK R A
Office of Nuclear Reactor Regulation
References
Download: ML19323F128 (1)