7/ - /, yoo gDL

"*... a o

"~

Babcock &Wilcox

,4,c,,a,,ue,iai, os,sn

[*,3. 'b 30 609 tiorth Warren Avenue, Apollo, Pa.15613

,y ry

~~

' 'M Telephone: (412) 842-0111

- a MG-rh, ;,hBOR

,N April 29, 1980

,\\

///g s

DochD.

Mr. Charles E. flacDonald, Chief US/v Transportation Certification Branch f,} /qy 0 9J Division of Fuel Cycle and Material Safety Washington, D.C. 20555 E-eqi[ Mis 9 gg, e U.S. fluc1 car Regulatory Commission G%ycrtoy C44 Docket No. 71-6400 g

'I

Dear Mr. MacDonald:

In resoonse to the request in your letter dated February 29, 1980, the following information is provided:

On April 23, 1980, Ouality Assurance inspected the Model 6400, "Supertiger" shipping packaoe identified as L-1, NUMEC property tag No. 202310, for conformance with Protective Packaging, Inc. Drawinas No. 32106-1, Sheet 1, Revision F, and 32106, Sheet 2.

Only those dimensions and characteristics which could be evaluated without dismantling the container were inspected.

In addition, the container was examined to determine the extent of any damage or deterioration of the package and the presence of holes or cracks in the inner liner.

The attached inspection report lists the characteristics inspected, the drawing specification and the observed measurement. The measurements found to be outside the drawing tolerances are indicated.

A visual examination of the nackage revealed no cracks or holes in the inner liner of the package.

However, several conditions were observed which require repair before the container is again used for nuclear material shipments.

(1) The inner surface of the cap (outer door) will be scraped, new sealant applied and repainted.

(2) The gasket on the inner surface of the cap will be replaced.

(3) The gasket on the inner surface of the closure plate (inner door) will be reglued in several places.

(4) The inner door gasket nating surface of the container will be scraped and repainted and the wood surface adjacent to the mating surface will be resealed and painted.

W ? fg M b QQ%

j 80052700/6 (

Q9 l

The Babcock & Wilcox Ccmpany / Established 1867

)

Babcock 4.Wilcox Mr. Charles E. MacDonald April 29, 1980

.i (5) The surfaces of the inner liner will be repainted.

I The repairs listed above will be completed so that the package will be available for use upon authorization by the NRC. All repairs will be documented with a description of the materials used and the work per-l formed. Quality Assurance will inspect the repair work to verify its I,

conformance to the applicable drawing.

If you have any questions regarding this information, please contact either myself or Mr. R. M. Jackman, Manager of Ouality Assurance.

l Sincerely,

<J Michael A. Austin Manager, Technical Control MAA/mhb Enc.

l r

4 i

1 1

I r

r

BABC0CK & WILC0X QUALITY CONTROL INSPECTION REPORT ITEM:

B&W Supertiger, Unit L-1, Property Tag #202310 DWG.:

32106-1 DATE:

APRIL 23, 1980 DWG.

STATUS CHARACTERISTIC LOCATION SPECIFICATION REQUIREMENT INSPECTION RESULT ACCEPT REJECT 1.WidthIto(

D7 7 ft. 5 in.

1/8 in.

7 ft.5 in.

ex 2.LengthktoE E6 19 ft.2 1/2" 1/8 in.

19 ft.2 1/2 in.

x

3. Overall Width C7 96 in.

iU' 90

/16

4. 0verall Height D

96 in.

in.

96 LN.

x

/16

5. D1 - D2 E7 1/2" in. Max.

1/4 in.

x 6.-D3 - D4 D6 1/2" in. Max.

1/4 in.

x

7. D5 - D6 D8 3/8" in. Max.

1/4 in.

x

8. Vents Closed (Note 7)

Vents Closed (All Sides) x 9* I" y ty Panel G4 3/16 in. Max.

Sides = 1 in., Floor = 7/16 in.

x atn s

10. External Container G5 1/4 in. Max.

35/64 x

Panels Flatness

11. Door Width B5 34 1/4 in.

1/8 in.

34 1/8 in.

x

12. Overall Length C6 238 1/2 in.

238 1/.4 in.

x j4

13. Dowel Pin B4 1 in. Dia.(4 Places) 1 in.Dia.(4 Places) x
14. Dowel Pin Length C4 2 in.

1/8 in.

1 3/8 in. Long x

15. Corner Re-enforcement C5 3"

1/8 in x 18" 1/8 3" x 18" (Typ. 8 Places) x 16.BoltPocketdto(

D4 22" 1/8 in.

22 in x

17. Bolt Pocket Size C4 6"

1/8" 5 3/4" x

18. Inside Cavity D3 76" x 76" x 172" 1/8 76" x 76" x 172" x
19. Container Length B2 204 1/4" 1/8" 204 1/8" x

GENERAL

'2 1.

Inside Cavity Door Contains 34 - 1/2 in. Dia. Bolts.

2.,

Inside Cavity Door Has Three Hinges.

3.

Inside Cavity Door Plate Thickness is.255 in.

4.

.Inside Cavity Door Gasket Thickness is.260 in.

5.

A Purge Hole is' Present in the Center of the Inside Cavity Door.

,6.

Outer Container Door Plate Thickness is.370 in.

Outer Container Door has 14 - 1 in. Dia. Bolts.

7.

8.

Outer Container Door Has Two Hinges with a Grease Fitting in Each Hinge.

9.

Plywood on the Inside of the Outer Door is.350 in. Thick.

10.

All Welds Visually Examined and Appear Sound and Free of Cracks.

11.

Four Re-enforcement Steel Plates are Welded on the Inside Cavity Back Wall.

7(. H.

zm to" a

A 7~

yg 9"

< N 'l o

7 t.,4 Y

8e y

dv $ k f 28-8o Q. A. SUPERVISOR R. E. ABEL

.