ML19323E198
| ML19323E198 | |
| Person / Time | |
|---|---|
| Site: | Hope Creek |
| Issue date: | 05/06/1980 |
| From: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Martin T Public Service Enterprise Group |
| References | |
| NUDOCS 8005230140 | |
| Download: ML19323E198 (1) | |
Text
,
4'3&
/ p ua<,,#'o UNITED STATES
! "'; ), ( ) g gp g
NUCLEAR REGULATORY COMMISSION e
REGION I 0, ' f ' %#
[
631 PARK AVENUE
,o' KING OF PRUSSIA, PENNSYLVANIA 19406 Docket Nos. 50-354 50-355 Public Service Electric and Gas Company ATTN.
Mr. T. J. Martin Vice President Engineering and Construction 80 Park Place Newark, New Jersey 07101 Gentlemen:
The enclosed IE Bulletin No. 80-10, " Contamination of Nonradioactive System and Resulting Potential for Unmonitored, Uncontrolled Release to Environment,"
is forwardcd to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, Boyce H. Grier d irector
Enclosures:
1.
List of Recently Issued IE Bulletins CONTACT:
J. Kinneman (215-337-5221) cc w/encls:
E. N. Schwalje, Manager - Quality Assurance, Engineering and Construction Department t
I l
t l
l 8*seso fyo
4 ENCLOSURE I SSINS No.: 6820 UNITED STATES Accessions No.:
NUCLEAR REGULATORY COMMISSION 8002280677 0FFICE OF INSPECTION AND ENFORCEMEitT WASHINGTON, D.C.
20S55 IE Bulletin No. 80-10 Date:
May 6, 1980 Page 1 of 2 l
CONTAMINATION OF NONRADI0 ACTIVE SYSTEM AND RESULTING POTENTIAL FOR UNMONITORED, UNCONTROLLED RELEASE OF RADI0 ACTIVITY TO ENVIRONMENT Description of Circumstance At the Brunswick Nuclear Facility, the auxilia y boiler was operated for an extended period of time with radioactively contaminated water in the boiler 2
at levels up to 2 x 10 micro curies per milliliter.
A tube leak in the firebox of the oil fired auxiliary boiler resulted in an unmonitored, uncon-trolled release of radioactivity to the environment.
The initial contaminating event was caused by the use of a-temporary heating hose from the auxiliary boiler to a radioactive waste evaporator concentrate tank.
Upon cooling and condensation of the steam in the temporary hose, contam-inated water r' phoned from the concentrate tank back to the auxiliary boiler.
Due to additional, continuing leaks in the heat exchanger of the waste evaporator (to which the auxiliary boiler also provides process steam), the licensee's efforts ta decontaminate the auxiliary boiler feedwater had been ineffective.
Maintenance of proper boiler chemistry was difficult because blowdown options were severely restricted due to the contamination.
As a result, a boiler tube failure caused on the order of 100 mil 11 curies of radioactive material to be released off-site via the auxiliary boiler fire box and smokesteck in the form
)
of steam.
This resulted in increased environmental levels of cesium and activa-tion products being detected as far as eight miles downwind from the site boundary.
1 Action to be Taken by Licensee with an Operating License 1.
Review your facility design and operation to identify systems that are considered as nonradioactive (or described as nonradioactive in the i
FSAR), but could possibly become radioactive through interfaces with radioactive systems, i.e., a nonradioactive system that could become contaminated due to leakage, valving errors or other operating conditions in-radioactive systems.
In particular, special consideration should be
.~
given to the following systems:
auxiliary boiler system, demineralized water system, isolation condenser system, PWR secondary water clean-up system, instrument air system, and the sanitary waste system.
2.
Establish a routine sampling / analysis or monitoring program for these systems in order to promptly identify any contaminating events which could lead to unmonitored, uncontrolled liquid or gaseous releases to the environment, including releases to on-site leaching fields or retention ponds.
l
,_._.._,,.-.._,.._t.
.,...__.#1
4 4
Enclosure I IE Bulletin No. 80-10 Date:
May 6, 1980 Page 2 of 2 3.
If these nonradioactive systems are or become contaminated, further use of the system shall be restricted until the cause of the contamination is identified and corrected and the system has been decontaminated.
Decon-tamination should be performed as soon as possible.
However, if it is considered nec6 =a j to continue operation of the system as contaminated, an immediate safety evaluation of the operation of the system as a radio-active system must be performed in accordance with the requirements of 10 CF, 30.59. The 10 CFR 50.59 safety evaluation must consider the level of cor'.mination (i.e., concentration and total curie inventory) and any pot 41al releases (either routine or accident) of radioactivity to the environment.
The relationship of such releases to the radioactive effluent limits of 10 CFR 20 and the facility's Technical Specification and to the environmental radiation dose limits of 40 CFR 190 must also be evaluated.
The record of the safety evaluation must set forth the basis and criteria on which the determination was made.
4.
If it is determined in the 10 CFR 50.59 safety evaluatio'n that operation of the system as a radioactive system is acceptable (i.e., does not involve an unreviewed safety question or a change to the Technical Specifications), provisions must be made to comply with the requirements of 10 CFR 20.201, General Design Criterion 64 to 10 CFR 50, Appendix I to 10 CFR 50 and the facility's Technical Specifications.
In specific, any potential release points must be monitored and all releases must be con-trolled and maintained to "As Low As is Reasonably Achievable" levels as addressed in Appendix I to 10 CFR 50 and within the corresponding environ-mental dose limits of 40 CFR 190.
However, if in the 10 CFR 50.59 determination it is determined that operation of the system as a radio-active system does constitute an unreviewed safety question or does require a change to the Technical Specifications, the system shall not be operated as contaminated without prior Commission approval.
f.ctions taken in response to Items 1 and 2 above shall be completed within 45 days froa the date of this Bulletin.
A verification letter shall be submitted within an additional 15 days to the Director of the appropriate NRC Regional Office.
This letter shall document the completior, of the required actions but need not delineate the specific actions taken.
The specifics shall be docu-mented and made available to the NRC for review during future onsite inspection efforts.
For facilities with a construction permit, no cetion is required.
The Bulletin is provided for information. Jhe subject of the Bulletin and the action required of operating plants should prove useful in the planning of systems designs and future operations.
Approved by GAO, B180225 (R0072); clearance expires 7-31-80.
Approval was given under a blanket clearance specifically for identified generic problems.
ENCLOSURE 2 IE Bulletin No. 80-10 Date: May 6, 1980 Page 1 of 1 RECENTLY ISSUED IE BULLETINS Bulletin Subject Date Issued Issued To No.
80-03 Loss of Charcoal From 2/6/80 All Power Reactor Standard Type II, 2 Inch, Facilities with an Tray Adsorber Cells OL or CP 80-04 Analysis of a PWR Main 2/8/80 All Power Reactor Steam Line Break with Facilities with an Continued Feedwater Ad-OL or CP dition 79-01B Environmental Quali-2/29/80 All Power Reactors fication of Class IE with an OL except Equipment SEP Plants 80-05 Vacuum Conditions 3/10/80 All PWR Power Reactor Resulting in Damage to Facilities with an Chemical Volume Control OL or CP System (CVCS) Holdup Tanks 80-06 Engineered Safety 3/13/80 All Power Reactor Feature (ESF) Rcset Facilities with an Controls 0-_ (For Action)
All Power Reactor Facilities with a CP (For Information)79-03A Longitudinal Weld 4/4/80 All Power Reactor Defects in ASME Facilities with an SA-312, Type 304 OL or CP Stainless Steel Pipe 80-07 BWR Jet Pump Assembly 4/4/80 BWR 3 & 4's with OL Failure (For Action)
BWR's with CP (For Information) j 80-08 Examination of Con-4/7/80 All Power Reactor tainment Liner Facilities with Penetration Welds an OL or CP 80-09 Hydromotor Actuator 4/17/80 All Power Reactor Deficiencies Facilities with an OL or CP
_ _ _.