ML19323D495

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-358/80-05 on 800221-22 & 0305-07 & Notice of Violation
ML19323D495
Person / Time
Site: Zimmer
Issue date: 04/02/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
Shared Package
ML19323D496 List:
References
NUDOCS 8005210613
Download: ML19323D495 (2)


See also: IR 05000358/1980005

Text

_

,

'

'o

UNITED STATES

[\\jgfl'g

NUCLEAR REGULATORY COMMISSION

i

. WA . e

REGION 111

.N

799 ROOSEVELT ROAD

o,g'V [

GLEN ELLYN. lLLINolS 60137

  • ...

APR 2 W

Docket No. 50-358

Cincinnati Gas and Electric

Company

ATTN:

Mr. Earl A. Borgmann

Senior Vice President

Engineering Services

and Electric Production

139 East 4th Street

Cincinnati, OH 45201

Gentlemen:

This refers to the inspections conducted by Mr. I. T. Yin of this office

on February 21-22, 1980, at the site, on March 5-6, 1980, at the corporate

office of Sargent and Lundy Engineers, and

March 7, 1980, at the NRC

Region III office of activities at the Wil'

m H. Zimmer Power Station

authorized by NRC Construction Permit No. t,cPR-88 and to the discussion

of our findings with Mr. W. W. Schwier and others of your staff at the

conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined

during the inspection. Within these areas, the inspection consisted of

a selective examination of procedures and representative records, obser-

vations, and interviews with personnel.

During this inspection, certain of your activities appeared to be in non-

compliance with NRC requirements, as described in the enclosed Appendix A.

This notice is sent to you pursuant to the provisions of Section 2.201 of

the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office within thirty days of

your receipt of this notice a written statement or explanation in reply,

including fer each item of noncompliance: (1) corrective action taken and

the results achieved; (2) corrective action to be taken to avoid further

noncompliance; and (3) the date when full compliance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part

2, Title 10, Code of Federal Regulations, a copy of this letter, the

enclosures, and your response to this letter will be placed in the NRC's

Public Document Room, except as follows.

If the enclosures contain

information that you or your contractors believe to be proprietary, you

,

8005210 @

e

i

Cincinnati Gas and Electric

-2-

Company

APR 2

1880

.

must apply in writing to this office, within twenty days of your " receipt

of this letter, to withhold such information from public disclosure.

The application must include a full statement of the reasons for which

the information is considered proprietary, and should be prepared so that

proprietary information identified in the application is contained in an

enclosure to the application.

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

.

-bA

w --

G. Fiorelli, Chief

Reactor Construction and

Engineering Support Branch

Enclosures:

1.

Appendix A, Notice

of Violation

2.

IE Inspection Report

No. 50-358/80-05

cc w/ encl:

J. R. Schott, Plant

Superintendent

Central Files

Reproduction Unit NRC 20b

.

PDR

l

Local PDR

-

NSIC

TIC

Harold W. Kohn, Power

Siting Commission

Citizens Against a

Radioactive Environment

Helen W. Evans, State

of Ohio

_

_