Forwards IE Bulletin 80-08, Exam of Containment Liner Penetration Welds. Written Response Required
ML19323A341
Person / Time
Site: Yankee Rowe
Issue date: 04/07/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Kay J
YANKEE ATOMIC ELECTRIC CO.
References
NUDOCS 8004180302
Download: ML19323A341 (1)


Text

__ _

.t

~~7NC -

[

o,,

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

D j

REGION I 0

631 PARK AVENUE 9 * ** * *,o'g 44 KING OF PRUSSIA, PENNSYLVANIA 19406 Docicet No. 50-29 April 7, 1980 Yankee Atomic Electric Company ATTN: Mr. James A. Kay Senior Engineer - Licensing 25 Research Drive Westborough, Massachusetts 01581 Gentlemen:

The enclosed IE Bulletin No. 80-08, " Examination of Containment Liner Penetra-tion Welds," is forwarded to you for action.

A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

&b

_ Boyce H. Grier Director

Enclosures:

1.

IE Bulletin No. 80-08 2.

List of Recently Issued IE Bulletins CONTACT:

L. E. Tripp (215-337-5282) cc w/encls:

H. Autio, Plant Superintendent J. E. Tribble, President 8 004180 3OR

i ENCLOSURE 1 SSINS No.: 6820 i

UNITED STATES Accessions No.:

NUCLEAR REGULATORY COMMISSION 7912190650 0FFICE OF INSPECTION AND ENFORCEMENT 1

U#g" 6 '

WASHINGTON, D.C.

20555 i

G.

IE Bulletin No. 80-08 Date:

April 7, 1980 Page 1 of 2 EXAMINATION OF CONTAINMENT LINER PENETRATION WELDS

[

i Description of Circumstances:

l On March 20-23, 1979, an NRC inspection at Nine Mile Point Unit 2, identified that certain nondestructive examinations. performed on containment penetration welds did not satisfy the applicable ASME Boiler and Pressure Vessel (B&PV)

Code requirements.

The welds in question were the primary piping containment penetration flued heac (integral fitting) to outer sleeve welds which form a part of the cont 2f:.sent pressure boundary.

The examinations performed included ultrasonic and surface inspections of the outer surface.

l Subsequent to the identification of this code problem at Nine Mile Point Unit l

2, three welds previously found to be acceptable using ultrasonics were radio-graphed and two revealed indications in excess of the code allowable.

The indications revealed by radiography were slag and lack-of-fusion.

Preliminary NRC review indicates that the probable reason the indications were not detected by ultrasonics was due to masking from signals received from the backing bar.

l As a result of these findings, a complete re-examination program at Nine Mile Point Unit 2 was initiated wherein 10 of 17 welds previously examined and found to be acceptable using ultrasonics, were re-examined by radiography i

before rework and found to have indications exceeding ASME Code allowables.

t Additional information concerning Beaver Val. ley Unit 2 and North Anna 3 and 4 has also shown cases of flued head piping penetration weld defects exceeding ASME B&PV Code acceptance criteria when radiographed.

Original approved vendor procedures at Beaver Valley Unit 2 did not require volumetric examina-tion.

Radiography for information purposes disclosed the unacceptable indica-tions at North Anna 3 and 4. Specification deficiencies have also been discovered l

at Millstone 3 and River Bend where radiography of these welds wcs not required.

The ASME B&PV Code requires radiography of the subject welds with specified I

exceptions.

The licensees and their architect engineer (Stone and Webster) had specified ultrasonics as the volumetric examination method because, in their judgement, radiography was impractical for the penetration geometry.

Radiography was successfully performed at North Anna 3 and 4 prior to the identification of this problem and at Beaver Valley 2 and Nine Mile Point 2 subsequent to NRC inspections.

This experience indicates that radiography was meaningful and more practical than UT examination of these penetration welds when backing bars are present.

s IE Bulletin No. 80-08

[

(

Date:

April 7, 1980 l

l Page 2 of 2 l

Action to be Taken by Licensee:

For all power reactor facilities with an operating license or a construction permit:

1.

Determine if your facility contains the flued head design for penetration i

connections, or other designs with containment boundary butt weld (s) between the penetration sleeve and process piping as illustrated in Figure NE 1120-1, Winter 1975 Addenda to the 1974 and later editions of the ASME B&PV Code.

i 2.

If an affirmative answer is reached for Item 1, determine the following:

a.

Applicability of the ASME Code including year and addenda and/or Regulatory Guide 1.19, b.

Type of nondestructive examinations performed during construction, c.

Type of weld joint (including pipe material and size) and whether or not backing bars were used, l

t d.

Results of construction nondestructive examinations, i.e., if repairs l

were required, this should be identified including extent of repairs and description of defects encountered during repair,- if known.

'l 3.

For those-facilities committed during construction to perform volumetric examination of such penetrations through SAR commitments which have not performed radiography, justify not performing radiography or submit plans 3

and schedules for performing radiographic examinations.

i Within 90 days of the date of this Bulletin, facilities with an operating

)

license or a construction permit shall submit the.information requested in Items 1, 2, and 3 of this Bulletin.

Reports shall be submitted to the Regional Director with a copy to the Director, Division of Reactor Construction Inspection, Washington, D. C.

20555.

Approved by GAO, B180225 (R0072); clearance expires 7-31-80.

Approval was given under a blanket clearance specifically for identified generic problems.

1 l -

.. ~ -.

ENCLOSURE 2 IE Bulletin No. 80-OR '

Date: April 7, 1980 Page 1 of 1 RECENTLY ISSUED IE BULLETINS Bulletin Subject Date Issued Issued To No.

80-01 Operability of ADS Valve 1/14/80 All BWRs with an Pneumatic Supply Operating License (OL) 80-02 Inadequate Quality 1/21/80 All BWRs with an Assurance for Nuclear OL or Construction Supplied Equipment Permit (CP) 80-03 Loss of Charcoal From 2/6/80 All Power Reactor Standard Type II, 2 Inch, Facilities with an Tray Adsorber Cells OL or CP 80-04 Analysis of a PWR Main 2/8/80 All Powe'r Reactor i

Steam Line Break with Facilities with an Continued Feedwater Ad-OL or CP dition 79-018 Environmental Quali-2/29/80 All Power-Reactors fication of Class IE with an OL except Equipment SEP Plants 80-05 Vacuum Conditions 3/10/80 AllPWRPowerReactoh Resulting in Damage to Facilities with an Chemical Volume Control OL or CP i

System (CVCS) Holdup Tanks 80-06 Engineered Safety 3/13/80 All Power Reactor Feature (ESF) Reset Facilities with an Controls OL (For Action)

All Power Reactor Facilities with a CP (For Information)79-03A Longitudinal Weld 4/4/80 All Power Reactor Defects in ASME Facilities with an SA-312, Type 304 OL or CP Stainless Steel Pipe 80-07 BWR Jet Pump Assembly 4/4/80 BWR 3 & 4's with OL Failure (For Action)

BWR's with CP (For l

Information)

I