ML19322E844

From kanterella
Jump to navigation Jump to search
Forwards LER 80-007/01T-0
Date released: 12/02/2019 Download: ML19322E844


LER 80-007/01T-0:on 800314,B&W Advised That Mating Wear Rings on Double Suction Pump Could Cause Pump Failure During Accident Conditions.Caused by Failure to Document Design Revision on Pump Design Drawings
ML19322E849
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/28/1980
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19322E849 (1)
Forwards LER 80-007/01T-0
ML19322E843
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/28/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19322E843 (1)