R:;gult. tory DUKE PCWER COMPm Powza BmLoneo 4aa Sorru Cucaca SrazzT, CuAar.oTTE, K C. asaon A. C. Tu rzs se..o. v.cc Pars.os.'

P.o. Box at7e p.covev.o

..e w......

August 16, 1974

. ~.

f,*

Mr. Angelo Giambusso j

Deputy Director for Reactor Projects Directorate of Licencing Office of Regulation U. S. Atomic Energy Commission Washington, D. C.

20545 Re: Oconee Nucle on Docket Nos. 0-269 -270

Dear Mr. Giambusso:

My letter of February 28, 1974 was in response to a verbal request by Mr. I. A. Peltier of your staff for information concerning control rod drive sy'.cem stator failures at Oconee Nuclear Station. We indicated in that - etter that part of the corrective action to prevent stator failures sould be the addition of a nitrogen cover gas system to maintain a vapor-free atmosphere against the stator insulation.

Since then, we have determined that such a cover gas system would have little, if any, effectiveness in preventing the stator failures we have ex-perienced.

Therefore, nitrogen cover gas systems will not be. installed on Oconee Units 1 and 2.

The results of the failure analyses presented in my February 28, 1974 letter are not changed by the deletion of this cover gas system.

Very truly yours,

[

6 (

N !l M 1

A. C. Thies h

  • GTG El 93 g v.s)

ACT:vr s

,a 3 cc:

Mr. Norman C. Moseley (F

n., a ed

=&

i qN.-

e v,

x Co 8716 7912040 M