Letter to N. C. Moseley from Duke Power Company dati.4 April 14,1975.

v DISTPHJTION:

50-269 B. D. Thornburg, IE IE:lRS (5)

Office of Standards Development 4'Tentral Files Division of Reactor Licensing (33)

PDR Local PDR NSIC l

TIC STATE a

a I

I s

v l

NEA cf\\

A/

-k' i

fg y y.qg QQ}-]

^ Duxz Powza COMPANY

^

l Powsm Eun.pnes 4a2 Sourm Gnunca SrazzT, CuAnzertz,N.C.sesos 1

A. C. THIES P. o. Box 217e Egmson vice Passios=t P=osuction a=o Taansasiseeon

  • f i

April 14, 1975 Mr. Norman C. Moseley, Director j

U. S. Nuclear Regulatory Commission Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 i

i Re:

Oconee Unit 1 Docket No. 50-269 Daar Mr. Moseley:

The following information concerning the hot zero power ejected rod worth measurement and the evaluation of the results thereof for Oconee 1, Cycle 2 is submitted as a special report.

The hot zero power ejected rod worths for Oconee 1, Cycle 2 were measured during the zero power physics testing on March 10 and 11, 1975.

The purpose of.these measurements was to verify that the measured maximum ejected rod worth at hot zero power conditions (a) is less than the Technical Specification 3.5.2.3 limit of 1.0% Ak/k when the reactor is critical with a normal control rod configuration and (b) i compare acceptably with the predicted value of 0.9 1 0.1% Ak/k.

The measurements were performed at zero power, 532 F, and 2155 psig conditions on control rods at core locations L-14 (Group 6 rod) and H-8 (Group 7 roc

predicted to yield the maximum ejected rod worth.

The test method

..tsisted of moving the designated control rod from the fully inserted position to the fully withdrawn position, compensating for the resulting reactivity change by either Control Rod Grcup 5 insertion or boron addition to the reactor coolant.

In order to compare the measured ejected TM worths with the predicted values, which were based on Group 5 at 0% wd, the measured ejected rod worths were extrapolated, wharr applicable, to Group 5 at 0% wd condition by using the correlation bscween ejected rod worth and inserted control rod group worth.

The results of the measurements indicated that the ejected rod worths would be less than the 1.0% Ak/k limit when the reactor is critical with the normal control rod configuration of Group 5 at 50% wd and Groups 6 and 7 fully inserted. However, the measured ejected rod worth at core location H-8 was 1.13% Ak/k when Group 5 was at a 9% wd position, thus exceeding j

i i

l

,,s

n Mr. Norman C. Moseley Page 2 April 14, 1975 the predicted value of 0.9 1 0.1*/ k/k. Therefore, in order to preclude lA any possibility of exceeding the Technical Specification limit on ejected rod worth, an administrative control requiring Group 5 to be at least 60 percent withdrawn prior to reactor criticality and during normal low power operation was invoked.

The initial calculations of the ejected rod worths were performed using a simplified PDQ model, which had compared favorably with the Cycle 1 The maximum ejected rod worth for the beginning of Cycle 2 measurements.

was predicted to be 1.02% Ak/k at core location L-14.

Based on the correlation between calculated and measured ejected rod worths available in November 1974 in B&W reactors, B&W expected the measurement to yield a value of 0.9

.1% Ak/k. However, calculations performed using a more detailed PDQ model with finer mesh spacings predicted a maximum ejected rod worth of 1.2% Ak/k at core location H-8.

Because of the conflict in predictions (finer mesh spacing calculations versus correlations with previous Cycle 1 measurements), establishment of the maximum ejected rod worth value was deferred until the measurements could be performed.

The results of the measurements agreed very closely with the finer mesh spacing model results, as shown in Enclosure 1.

Thus the discrepancy between measured and predicted ejected rod worths has resulted from using a simplified model.

The variation of the ejected rod worth with core lifetime, as predicted by the more detailed model, is such that the maximum ejected rod worth (with Group 5 fully inserted) increases from 1.2% Ak/k at the beginning-of-cycle to 1.25% Ak/k at 50 EFPD, becomes 0.74% Ak/k following the j

control rod interchange at 50 EFPD, and increases to 0.80% Ak/k at the j

end-of-cycle. Duke and B&W have reviewed the results of this more detailed model calculation along with the measurement results and have determined that withdrawing Control Rod Group 5 to a minimum 60% withdrawn position prior to criticality and during normal low power operation will assure adequate margin for the 1.0% Ak/k Technical Specification limit until the control rod interchange.

After the control rod interchange, no minimum withdrawal of the regulating groups (5, 6 and 7) is required to assure that the 1.0% Ak/k Technical Specification limit is met.

Thus, the discrepancy between the measured ejected rod worths and their predicted values for Oconee 1, Cycle 2 has been satisfactorily resolved; and appropriate administrative controls have been implemented for ensuring an adequate margin for the Technical Specification limit on ejected rod worth,s.

Very truly yours, A. C. Thies ACT:vr Enclosure MTPwe -

--wg 9

=-w-

CALCULATED VALUES COMPARISON OF MEASURED EJECTED ROD WORTHS WITl4

'(Oconee 1, Cycle 2, BOL, Zero Power, 532 F, and 21.15 psig Conditions)

Ejected Rod Worth (% Ak/k)

Contrcl Rod Group 5 Measured Worth When Position When The Core Location of Extrapolated t Calculated Designated Ejected Group 5 Position of W

h Control Rod for Rod is Fully With-Measured Ejected Rod Worth Measurement Test Method drawn (% vd)

Worth 0% wd 8

0.46 0.50 0.58 L-14 Rod Swap L-14 Rod Swap 51 0.20 L-14 Rod Swap 78 0.15 H-8 Rod Swap 9

1.13 1.20 1.20 l

H-8 Boron Swap 62 0.64 i

i Extrapolation of measured ejected rod worths to Group 5 at 0% wd condition is valid only Note:

for those cases when Group 5 is less than 20% wd.

Calculated ejected rod worths correspond to Group 5 at 0% wd condition.