Text

,,

.

.

.

UNITF.D STATES

ATOMl! ENERGY COMMISSION

I ei

e

i

DIVISION OF COMPl.!ANCE

REGION 11 - SutT E 818

230 PEACHTREE ST RE ET. NORT NwCST

AT L. A NT A. GEORGI A 30303

March 2h, 1972

J. G. Keppler, Chief, Reactor Testing and Operations Branch

Division of Ccmpliance, Headquarters

DUKE PCVER COMPANY (OCONEE 1), LICENSF NO. CPPR-33, DOCKET NO. 50-269

The attached report of a routine unannotaced inspection at the subject

site on January 18-21, 1972, is forwarded for information. Two items of

nonccmpliance with 10 CFR 50, Appendix B, were included in the Region II

letter to Duke concerning this inspection.

The report discusses actions Duke has taken to resolve velding program

deficiencies.

Subsequent to this inspection, the SvRI has completed

their review and Duke has contracted for a';cther consultant to perform

an independent review of the effect the program deficiencies had on the

quality of the velds.

We plan an early inspection to review in depth

the results cf these Duke efforts.

Subsequent to the inspection, it was decided that a citation should not

be made for failure to measure vall thicknesses of all safety-i=portant

valves. No further action on this matter is planned by Region II until

further guidance is provided by Compliance Headquarters.

/?W

N. C. Moseley

CO:II:NCM

Senior Reactor Inspector

Enclosure:

C0 Rpt. No. 50-269/72-1

(Murphy)

cc v/ encl:

E. G. Case, DRS (3)

J. P. O'Reilly, C0:I

R. S. Loyd, DRL (2)

3. E. Grier, C0:III

R. C. DeYoung, DEL (2)

J. W. Flora, CO:IV

D. J. Skovholt, DRL (3)

R. W. Snith, CO:V

H. R. Denton, DRL (2)

C0 Files

L. Kornblith, Jr., C0

DR Central Files

R. H. Engelken, C0

J. B. Rendersen, CO

,

7 911210 73Q

1