ML19322A313

From kanterella
Jump to navigation Jump to search
Based on Review of 790228 Info Re Decay Heat Pump impeller- to-casing Rubbing,No Effects or Results of Rubbing Could Be Noted
ML19322A313
Person / Time
Site: Crane 
Issue date: 03/21/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Herbein J
METROPOLITAN EDISON CO.
References
NUDOCS 7904090391
Download: ML19322A313 (2)


Text

.

.;I t ei Jt v.b t

gsMaoqS UNITED STATES g

NUCLEAR REGULATORY COMMISSION 3'..

.'Mj)

_{,,D/j WASHINGTON, D. C. 20555 t,, '

'I March 21, 1979 Docket No. 50-289 Mr. J. G. Herbein Vice President Metropolitan Edison Company P. O. Box 542 Reading, Pennsylvania 19640

Dear Mr. Herbein:

By letter dated February 28, 1979 you provided information to support the position that decay heat pump (DHP) impeller to casing rubbing, as experienced at Crystal River Unit 3, was not a concern for the similar pumps at Three Mile Island Unit 1.

In this regard, you state that the DHP impellers and originally installed shafts were examined during the 1978 refueling outage and no indications of rubbing or the effects of rubbing were found. Based on these examination results, the satisfactory operating history of your DHP's and the manufacturing differtnces between the TMI-l and CR-3 DHP casings documented in your submittal we conclude that there is reasonable assurance that the DHP impeller to casing rubbing, as experienced at CR-3,.is not a concern at TMI-1.

Sincerely, c'

,fj,/.

R. W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors cc: See next page l

7904090% -

F-f*etropolitan Edison Company l

cc:

G. F. Trowbridge, Esquire Shaw, Pittman, Potts & Trowbridge 1800 ft Street, N.W.

Washington, D.C.

20036 GPU Service Corporation Richard W. Heward, Project Manager Mr. E. G. Wallace, Licensing Manager 260 Cherry Hill Road Parsippany, New Jersey 07054 Pennsylvania Electric Company Mr. R. W. Conrad Vice President, Generation 1001 Broad Street Johnstcwn, Pennsylvania 15907 fliss !!ary V. Southard, Chairman Citizens for a Safe Environment P. O. Box 405 Harrisburg, Pennsylvania 17108 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 420, 7735 Old Georget'cwn Road Bethesda, liaryland 20014 Government Publications Section State Library of Pennsylvania Box 1601 (Education Building)

Harrisburg, Pennsylvania 17126 i

l l

l l

l l

!