400 Chestnut Street Tower 11 July 29, 1980 Director of Nuclear Reactor Regulation Attention:

Mr. A.

Schwencer, Chief Light Water Reactors Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Schwencer:

u: the Matter of the Application of

)

Docket Nos. 50-327 Tentessee Valley Authority

)

50-328 In accordance with the requirements of the Safety Evaluation Report Supplement No. 1, TVA has conducted a test of the Sequoyah Nuclear Plant Auxiliary Building Gas Treatment System (ABGTS) in accordance with technical specification 4.7.8.1(d)(3).

A negative pressure equal to or more negative than minus 1/4 inch water gauge relative to the outside atmosphere was achieved in the ESF punp rooms while maintaining a vacuum relief flow greater than 2000 cfm and a total system flow of 9000 cfm and a total system flow of 9000 + 10 percent.

Very truly yours, TENNESSEE VALLEY AUTHORITY i

,/ll l

C

/.,

.r.-

^1 /+ l L. M. Mills, Manager Nuclear Regulation and Safety

$oN 5

/o 800 7810