ML19320D551

From kanterella
Jump to navigation Jump to search
Informs of Affirmative Findings in Response to IE Bulletin 80-08 Re Existence of Flued Head Designed Penetration Connections.Addl Items Concerning Penetration Assemblies Also Discussed
ML19320D551
Person / Time
Site: Yankee Rowe
Issue date: 06/25/1980
From: Moody D
YANKEE ATOMIC ELECTRIC CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-08, IEB-80-8, WYR-80-73, NUDOCS 8007210506
Download: ML19320D551 (1)


Text

W%

Telephone 617 366-9011 TwK 70 390-0739 YANKEE ATOMIC ELECTRIC COMPANY B.s.1.1.

WYR 80-73 i

20 Turnpuke Road Westborough, Massachusetts 01581 June 25,1980 United States Nuclear Regulatory Commission Region I, 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Boyce H. Grier, Director

Reference:

(a) License No. DPR-3 (Docket No. 50-29)

(b) USNRC Letter to YAEC dated April 7, 1980

Subject:

Response to IE Bulletin No. 80-08

Dear Sir:

Reference (b) requested we determine if our facility contained flued head designed penetration connections, or other designs with containment boundary butt welds as specified. This letter is to inform you of our affirmative findings (both) and respond to the additional items of Reference (b).

a.

The 1956 Edition of the ASME Code,Section VIII, applied to the fabrication and installation of containment penetration assemblies.

b.

The vapor container specification required (1) complete radiographic inspection of all welded seams, and (2) Magnarlux inspection of the welds of the reinforcing of all openings in the shell. Due to non-existent records, the extent of nondestructiv'e examination cannot be verified.

j c.

Details of the vapor container piping penetrations are provided on the attached drawings.

Pipe size and material type are also denoted on these drawings.

It is unknown whether backing rings were used or not: no mention of backing rings is made on these drawings.

d.

A search of both plant and constructor records has found no records documenting the nondestructive examination of the vapor container penetration assemblies during construction.

Should you have any additional questions, please contact us.

Very truly yours, YANKEE ATOMIC CLFCTRIC COMPANY D. E. Mo dy Manager of Operations JAK/kar

.firector, Division of Resctor Construction Inspection cc:

U.S. '?iclear Regulatory Cortmission Washington, DC 20555 8007g39 %

e,