ML19320D211
| ML19320D211 | |
| Person / Time | |
|---|---|
| Issue date: | 06/30/1980 |
| From: | Mattia M NRC OFFICE OF ADMINISTRATION (ADM), WASHINGTON, STATE OF |
| To: | |
| Shared Package | |
| ML19320D206 | List: |
| References | |
| CON-FIN-B-1652, CON-NRC-06-80-306, CON-NRC-6-80-306 NUDOCS 8007210113 | |
| Download: ML19320D211 (5) | |
Text
_. - _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5TANDARD FCRM 30, JULY 1966
- AG8 i
O'
- oeNe.u seiv,Cas
,.o-asnAfioN AMENDMENT CF SOLICITATION / MODIFICATION OF CONTRACT 1
2 MD. PeOC. 8tG.148 CPEI l-I Allt
- 3. EtQutSITION/ PURCHASE #fGUEST 7
- 4. PRO >tCT NO. (if apptase/s>
- 1. Am&NOktNY/naCOiFiCAllON NO.
- 2. RPf tCT1vt DATE RFPA No. OSP-80-30 ONE (1)
- s. tssuto av coor
- a. AomeasTeeno sv af.,a.,,4.
64 4 se coot l U.S. NUCLEAR REGULATORY COMmsdwa DIVISION OF CONTRACTS WASHINGTON, D.C.
20555
- r. CoNnACTon cooe l l
FAcsiiTY cooEt 8-NAME AND ADDetSS AaAINOMENT OF GscuCrrAr>ONNo.
I l
STATE OF WASHINGTON OEPARTMENT OF SOCIAL AND HEALTH SERVICES
( s,,-,.
""UJ.'."-
MAIL STOP LDil g @ f'"T ", '
- o. NRc-06-80-306 C
,N OLYMPIA, WASHINGTON 98504 ca,,
l2/7S/79 (S. 6/.4 I f)
OAft0
- 7. THs3 sLOCK APPuts ONLY TO AmtNOmtNTS Cf $OUCTAflCNS
] %.
2 tA.ed.h.m e.
n e., 8
.a bs a l 2.
Th. h,.a.
.A f., c o..i 08 O... <.d. O.
-~
o.
-...-.u
.~,...
(stly e. n.n,.n..
-.i me. :
i bt 8, ma.wi g.a.
ee,. f *...e.a..ea,.a. h..e,.f *..#.e b.
e.;., (c 4, wp l.#.'.
l.g,..
F Af.uat Of Yous ACKNOWL2DGtmfNT TO 88 ft.ClivfD AT THE IS$UlNG OMICE Patot 4.h.ccl.
8.e.a..,.th.no wh.,.n..n
. w
.e w
..o,.,...
.a w
otre s, Cmeo -Av usutiiN us CnoN or Tove ome.
. i.. a
~
.w..
..a a,,,
aw.
IQ. ACCQuNTING AND AP.tCPflAflCN DATA (1/ q.sreds 83R FIN APPROPRIATION INCREASE 8U T9-08-03 B1652 31X0200.800
$37,380.00.
II. TH,5 eLOCK AMuts CMT 70 ancoirtCAT10NS OF CONTRAC'5/CEDets m O a Ch.
o,.
w
- m. Cs
. b is z,
m O n..-.
-,, /
au
.A
.'*"Te"c
.. 'f*If Urn al um"*M'il f,,,,'
P.L.95-604 tion 20 ic @ n.. -
- q
...,.y,.,,,,,,,,
TAILINGS RADIATION CONTROL ACT n, 6a-..
2.
.. w
,2.
- 12. 0 SCRAFTICN CP AnttNOmENf/anOOrtCATICN The purpose of this modifcation is to increase the funding by $37,380.00 from
$42,620.00 to $80,000.00 l
- 1. Under Section 14 FUNDING SOURCES AND ALLOCATION TO PROJECT TIME UNITS, change the total from $42,620.00 to "$80,000.00."
- 2. Under Section 16, REMARKS, delete that in its entirety and substitute the following in lieu therof; j
i "This Grant Award of $80,000.00 has been made in accordance with the following:
- 1) Preparation of Legislation and Regulations
$31,594.00
- 2) Development of Administrative Procedures S 3,226.00
- 3) Training of State Employees
$ 9,380.00'
- 4) Purchase of Equipment
$35,800.00 GRAND TOTAL
$80,00000 D,,D,, D),]2 }$$
o o.
o Ju U.
- lhi_,
_.,~..,t..._,,,,,..,
i.- - -.a -.
, 3.
O
@ fo"5 5 00Cu CONTaAC'Ce/CMenos rs atoutato sacN THis JMfMT AND EfTUNN COPtFS fC.,55UING CM<t
- 14. NAmf CF CONTRACTOR /CrPtect t r. UNff 7 $ OF M / /'y [ / _
b-8Y sf I
-m-
- 15. NAsad AND TITLE CP SIGNtf (Typ, gr pr gj.,,, _,,
.13,3 AIL pON(Q_ _._{ $,J4A44f, CT.CO,47RACWeG,GM GlLL(?pg,,2Fyly,j_.,,,,,,,, _,[f JATjJ0QN(!L MARY J0 MATTIA
' '% 0 07210 ll 3
" " " * " " ' ~ " " ' " - " ' ' ' ' " -
PAGE 2 0F 2 NRC-06-80-306 MODlFTCATION 1
- 3. Add the following Section 21; "21. Attached is a copy of Uranium Mill Instruments (TABLE 1). Priority must be given in the expenditure of the Equipment funds to the acquisition of any equipment that is identified therein and not available."
1 1
)
- * * * * * + * = = _ _ _
=w
~.
Table 1 Uranium Mill Instruments 1.
Radiation Instruments A.
A portable, battery-powered high voltage supply with ratemeter and scaler functions is recommende'? and may be used with G-M, gamma scintillation, or proportional counter probes.
B.
Survey Meter with end-window probe.
C.
Alpha scintillation survey meter.
D.
Radon daughter survey meter.
E.
Additional survey meter as B. above, with NaI crystal for gamna scintillation measurements would be useful.(cau')
2.
Air Samplino Ecuioment A.
Area Air Samplers - High volume dir samplers should be provided at strategic locations in the mill whereby any fugitive dust is likely to concentrate.
B.
Personal Air Samplers - Portable, lapel type. Worker breathing zone samples to be acquired with an air flow approx. 3-7 LPM.
C.
Radon Air Sampling Equipment Radon / Radon Daughter Detector to have the following capabilities:
1.
Simultaneous sampling and detection of Rn-222 and Radon daughters.
2.
Thoron detection.
3.
Ability to determine Ra-226 and Rn-222 in water and effluents.
4.
Sensitivity to 0.01 working levels when used with a Zns (Ag) scintillator.
5.
Linear response.
6.
Portability for field measurements.
3.
Calibration Eouimtent A.
Gamma calibrator or irradf.ptor o
B.
Alpha calibrator C.
Air Flow calibrator
~
If the above are not feasible, evidence that instruments have been calibrated by a recognized facility is acceptable.
i, VII. It4STRtriEtlTATI0t1 A.
The State, as a minimum,should have available both field and laboratory instrumentation sufficient to ensure the licensee's control of materials and to validate the licensee's measurements.
The minimum field type instrumentation which should be available for such measurements is as shown ir. Table 1.
By referring to specifi,cationssheets on the su.ggested eodipment, one can detar-mine the requirements needed for any other survey equipment which will provide equivalent data and measurements to those listed in Table 1.
Additionally, arrangements should be made for calibrating such equipment. Back-up instrumentation should also be considered so that the necessary equipment is available for emergency situations.
B.
Laboratory type instrumentation should be available in a State agency or through a commercial service which has the capability i
for quantitative and qualitative analysis of radionuclides associated with natural uranium and its decay chain, primarily; U-238, Ra-226, Th-230, Pb-210, Po-210, and Rn-222, in a variety of sample media such as will be encountered from an environmental sampling program.
s s-
- - - - * ~
- * * * ~ ~
- * * * =
e
e : *
- 1, -
Analysis and daLa reduction Irom laboratory analyLical f acilities should be available to the licensing and inspecting authorities in a timely manner. Normally, the data should be available within 30 days of submittal.
State acceptability of QA programs should also be established for the analytical laboratories.
C.
Arrangements should also be completed so that a large number of samples in a variety of sample media resulting fecm a major accident can be analyzed in a time frame that will allow timely decisions to be made regarding public health and safety.
D.
Medical consultants recognized for their expertise in emergency medical matters relating to the intake of uranium and its diagnosis thereof associated with a uranium concentrator should be identified and available to the State for advice and direct assistance.
v 6
yQ
- MOO MbWM' 1p