V O. S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGION I Report No.
70-371/80-06 Docket No.70-371 License No.
SNM-368 Safeguards Group 1
Licensee:
United Nuclear Corporation 67 Sandy Desert Road Uncasville, Connecticut 06382 Facility Name:
Naval Products Division Inspection At:
Uncasville, Connecticut Inspection Conducte'd:
April 7-11, 14-18, 1980 Date of Last Material Control and Accounting Inspection:
March 20, 1980 Type of Inspecti Announced Material Control and Accounting Inspectors:
/ 9)
$0 70 Y. Bi~ssett, Safeguards Auditor
' date
,Y I'7 2
D. Holody, Mathematical Statistician date i
3#
E. Shaub, Safeguards Lab Technician date k.
5 l12 8o R. Summers, Safeguards Auditor date f
30 0
.Joltner, eguards Auditor date Approved by:
/
d F//2./do i
/ dat'e H. Joyner, efgNuclearMaterialControl Support Sec on, eafeguards Branch Inspection Summary:
Areas Inspected:
Inventory verification; physical inventory reconciliation and measurement and statistical control. The inspection involved 155 i6spector-hours onsite by five NRC inspectors and was begun during the regular hours.
Results:
The licensee was found to be in compliance with NRC requirements in the areas _ examined during the inspection.
Region I Form 166
.(August 1979) 8007190084L