ML19320C694

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-09, Hydramotor Actuator Deficiencies. No Itt General Controls AH-90 or NH-90 Series Hydramotor Actuators Used in safety-related Sys
ML19320C694
Person / Time
Site: Yankee Rowe
Issue date: 06/18/1980
From: Moody D
YANKEE ATOMIC ELECTRIC CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-09, IEB-80-9, WYR-80-68, NUDOCS 8007170582
Download: ML19320C694 (1)


Text

17s Telephone bl7 366-90H TwK FIO-390-0739 YANKEE ATOMIC ELECTRIC COMPANY "rn so-s8 J..------.-s,

B.4.1.I r% ' lh 20 Turnpak< Road Wastborough, Massachusotts 01581 bK

,m.fE June 18, 1980 United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region I

' 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Boyce 11. Cr.ter, Director

References:

(a)

License No. DPR-3 (Docket No. 50-29)

(b) USNRC Letter to YAEC dated April 17, 1980 I&E Bulletin No. 80-09

Dear Sir:

Subject:

USNRC IE Bulletin No. 80-09; "llydramotor Actuator Deficiencies" As required in reference (b), we are providing the follo ing information.

We have determined that there are no ITT General controls All-90 or Nil-90 series llydramotor Actuators used in safety-related systems at the Yankee Atomic plant.

We, therefore, plan no further action with regard to this Bulletin.

We trust that you find this information satisfactory; however, should you desire additional information, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

[I p

D.\\j:. Moody 1tP Manager of Operations BLD/am seen g o S$'2-

.