ML19320B493

From kanterella
Jump to navigation Jump to search
Forwards Second Interim Deficiency Rept Re Cracks in Reactor Pressure Vessel Shield Wall.Final Rept to Be Submitted Before 801003.Will Provide Addl Info Re Repair of Shield Wall & Corrective Actions
Date released: 11/30/2019 Download: ML19320B493


Second Interim Deficiency Rept Re Cracks in Reactor Pressure Vessel Shield Wall.Discovered Base Metal Cracks in Shield Wall Inner Shell Plates.Evaluation Revealed Crack Initiated at Toe of Tack Weld Bead of Backing Strip
ML19320B496
Person / Time
Site: Hartsville 
Issue date: 07/03/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19320B496 (2)
Forwards Second Interim Deficiency Rept Re Cracks in Reactor Pressure Vessel Shield Wall.Final Rept to Be Submitted Before 801003.Will Provide Addl Info Re Repair of Shield Wall & Corrective Actions
ML19320B492
Person / Time
Site: Hartsville 
Issue date: 07/03/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19320B492 (1)