June 26, 1980 ST-HL-AE-485 SFN: V-0530 Mr. Karl Seyfrit Director, Region IV Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76102
Dear Mr. Seyfrit:
South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Interim Report on the Deficiency Concerning the ECW Gantry Crane Seismic Analysis On May 29,1980, Houston Lighting & Power Company notified your office of a potentially reportable deficiency concerning seismic qualification of the Essential Cooling Water Intake Structure (ECWIS) gantry crane and the Diesel Generator Fuel Oil Storage Tank. The Safe Shutdown Earthquake (SSE) response spectra values used in designing the two components were detemined by mul-tiplying the Operating Basis Earthquake (0BE) values by 1.5 ( as stated in the crane specification) rather than by a factor of 2.0.
The factor of 2.0 should have been used in order to envelop the actual required SSE response spectra.
This concern was first identified during a review of the design of the ECWIS gantry crane. A subsequent check of other mechanical specifications revealed a similar situation with the standby diesel generator fuel oil storage tank in the diesel generator building.
New seismic calculations for the gentry crane and the storage tank which will incorporate the 2.0 factor are. currently in progress. How-ever, preliminary indications are that the designs of both components are sufficiently conservative since they anticipate load combinations more severe in impact than expected seismic loads.
Consequently, modifications are not anticipated. Any additional infomatlon resulting from these calculations should be available to HL&P by mic -September,1980. Additionally, EL&P and B&R are soliciting inquiries from reput3ble consulting fims to 1
80070ggf g
Houston Lighting & Power Company June 26, 1980 ST-HL-AE-485 SFN: V-4530 Page T investigate and evaluate the seismic qualifications of equipment to be used at STP.
The next report on this potentially reportable deficiency will be sub-mitted to the NRC by October 1,1980. Any questions on this item should be directed to Mr. Shawn Rodgers, (713) 676-7953.
Very truly yours, D..A A a A G._W. Oprea, Jr.
4 Executive Vice President PLW/pjb l
Houston Lghting & Pur company ST-HL-AE-485 Page 3
cc: D. G. Barker C. L. McNeese H. R. Dean R. L. Waldrop G. B. Painter A. J. Granger R. A. Frazar M. D. Schwarz (Baker & Botts)
R. Gordon Gooch (Baker & Botts)
J. R. Newman (Lowenstein, Newman, Reis, Axelrad & Toll)
Director, Office of Inspection & Enforcement Nuclear Regulatory Commission
)
Washington, D.C. 20555 M. L. Borchelt Executive Vice President Central Power & Light Company P. O. Box 2121 Corpus Christi, Texas 78403 R. L. Range Central Power & Light Company P. O. Box 2121 Corpus Christi, Texas 78403 R. L. Hancock Director of Electrical Utilities City of Austin P. O.
Box 1088 Austin, Texas 78767 M. C. Nitcholas City of Austin P. O. Box 1088 Austin, Texas 78767 J. B. Poston Assistant General Manager of Operations City Public Service Board P. O.
Box 1771 l
San Antonio, Texas 78296 A. vonRosenberg City Public Service Board P. O. Box 1771 San Antonio, Texas 78296
Houston Ughting & Power Company ST-HL-AE-485 Page 4 Charles Bechcefer, Esquire Chairman, Atomic Safety & Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. James C. Lamb, III 313 Woodhaven Road Chapel Hill, North Carolina 27514 Dr. Emmeth A. Luebke Atomic Safety & Licensing Commission U.S. Nuclear Regulatory Commission Washington, D.C.20555 Steven A. Sinkin, Esquire 116 Villita Street San Antonio, Texas 78205 Citizens for Equitable Utilities c/o Ms. Peggy Buchorn Route 1 Box 432 Brataria, Texas 77422 Richard W. Lowerre, Esquire Assistant Attorney General for the State of Texas P. O. Box 12548 Capitol Station Austin, Texas 78711 Henry J. McGurren, Esquire Hearing Attorney Office of the Executive Legal Director U.S. Nuclear Regulatory Commission Washington, D.C. 20555 I
__,