Attachment A to AECM-80/141 Page 1 of 1 FINAL REPORT, PRD-80/11 ("odel 1152 Pressure Transmitter)
I.
Description of Deficiency The 1152 Pressure Transmitter has a common-mode failure of a capacitor when the transmitter operating temperature is greater than 175 F or when the damping potentiometer is rotated clockwise. The failure is mainifested as a drop in transmitter output current up to 10% of the correct current.
II.
Safety Implications Due to the inherent safety functions of these devices, failure would adversely affect the safety of operation of Grand Gulf Nuclear Station, Units 1 and 2.
As an example, when the 1152 Transmitter is used as a pressure transmitter, the deficiency can result in transmitting reactor pressure 10% lower than actual.
III. Corrective Action Taken
, General Electric has issued Field Disposition Instructions (FDI's) to repair defective Model 1152 Pressure Transmitters on site.
Details of the corrective action are delineated in the following FDI's:
Unit 1 Unit 2 Transmitters FDI-WAME FDI-WBIY
?