Non-Routine, Non-Radiological Environmental ' Report No. 50-313/75-26 s
2.
Report Date:
5/6/75 3.
Occurrence Date:
4/21/75 4.
Facility:
Arkansas Nuclear One-Unit 1 Russellville, Arkansas 5.
Identification of Oc'currenc.e:
Turbidity increase in plant circulating water exceeded Environmental Technical Sp'ecification limits per ETS 2.3.3 and ETS 4.1.1.a(4).
6.
Conditions Prior to Occurrence:
Steady-State Power Reactor Power MWth Ibt Standby Not Output MWe Cold Shutdown X
Percent of Full Power Refueling Shutdown Load Changes During Routino Power Op' ration e
(}
Routino Startup
\\
/
Operation w'
Routine Shutdown Operation Other (specify)
Plant shut down for maintenance.
7.
Description of Occurrence:
~;
Sampics taken at intake and discharge show that turbidity in the discharge canal.was 200% greater that turbidity in the intake canal (intake - 10 JTU,
' discharge - 30 JTU).
~
BOO $ 210
,/ -
\\_)
bbrch 4, 1975 NSP-10, Rev. 2 Page 2 of 4
N Non-Routine, Non-Radiological Environmental Report No. 50-313/75-26 i
n 8.
Designation of Apparent Cause of Occurrence:
a Design Procedure j
l Manufacture Unusual Service Condition Including Environmental Installation /
Construction Component Failure Operator Other (specify) 4 Sample inaccuracy.
J
'9.
Analysis of Occurrenec:
It is believed that sanrples taken were not truly representative of lake conditions; taerefore, occurrence is not realistic. Four circulating water pumps were running at time of sample collection and no liquid releases were in progress. No trash grinding was'in progress.
i
~
O March 4, 1975 NSP-10, Rev. 2 Page 3 Of 4 O
S x
9
.~
}
o c,
A I-Non-Routine, Non-Radiological Environmental Report No. 50-313/75-26 4
10.
Corrective Action:
l Turbidity and conductivity tests will be performed as soon as possible following sample collection in the future to interrogate results.
_ Questionable.results will b,e verified by resampling.
In addition, testing is being done to verify sample accuracy.