ML19319E441

From kanterella
Jump to navigation Jump to search
Forwards Nonroutine,Nonradiological Environ Repts 50-313/75-14,50-313/75-15,50-313/75-16 & 50-313/75-17. Jd Phillips 750224 Affidavit Encl
Date released: 11/29/2019 Download: ML19319E441


Nonroutine,Nonradiological Environ Rept 50-313/75-17:on 750217-18,fish Kill on Intake Screens Was 4,945 Lb Exceeding 3,000 Lb Limit for 24-h Period.Threadfin Shad Comprised 98% of Impinged Fish
ML19319E469
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/18/1975
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E469 (2)
Nonroutine,Nonradiological Environ Rept 50-313/75-17:on 750218,during Routine Fish Impingement Monitoring,Fish Kill on Intake Screens Exceeded 3,000 Lb Limit for 24-h Period. Caused by Natural Winter Die Off of Threadfin Shad
ML19319E468
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/21/1975
From: Murphy W, Woodward J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E468 (3)
Nonroutine,Nonradiological Environ Rept 50-313/75-16:on 750217,during Routine Fish Impingement Monitoring,Fish Kill on Intake Screens Exceeded 3,000 Lb Limit for 24-h Period. Caused by Natural Winter Die Off of Threadfin Shad
ML19319E467
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/21/1975
From: Murphy W, Woodward J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E467 (3)
Nonroutine,Nonradiological Environ Rept:On 750215-16, Protected Fish Kill on Intake Screens Exceeded 3,000 Lb Limit for 24-h Period Per 2,005 Lb Sample Obtained During 8-h Period on 750215.Caused by Natural Fish Die Off
ML19319E465
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/18/1975
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E465 (3)
Nonroutine,Nonradiological Environ Rept 50-313/75-15:on 750216,during Routine Fish Impingement Monitoring,Projected Fish Kill for 24-h Period Exceeded 3,000 Lb Limit Per 8-h Sample Period on 750215.Caused by Natural Winter Die Off
ML19319E459
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/21/1975
From: Murphy W, Woodward J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E459 (3)
Nonroutine,Nonradiological Environ Rept 50-313/75-14:on 750214-15,fish Impinging Upon Intake Screens Exceeded 3,000 Lb Limit for 24-h Period.Threadfin Shad Comprised 96% of Impinged Fish
ML19319E453
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/15/1975
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E453 (3)
Nonroutine,Nonradiological Environ Rept 50-313/75-14:on 750215,during Routine Fish Impingement Monitoring Using Procedure 1607.10,fish Killed on Intake Screens Exceeded 3,000 Lb Limit for 24-h Period.Caused by Natural Die Off
ML19319E448
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/21/1975
From: Murphy W, Woodward J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19319E448 (3)
Forwards Nonroutine,Nonradiological Environ Repts 50-313/75-14,50-313/75-15,50-313/75-16 & 50-313/75-17. Jd Phillips 750224 Affidavit Encl
ML19319E440
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/24/1975
From: Murphy W
ARKANSAS POWER & LIGHT CO.
To: CASE E G
Office of Nuclear Reactor Regulation
References