Ni lE FILE COPY C'.~!':52
[
sACRAMEtiTO MUNICIPAL UTILITY oisTRICT Q 6201 s street. Box 15830. Sacramento, califomia 95813; (916) 452 3211 (v)
Q April 18,1978 u
D
- v Director of Regulatory Operations ATTN: Mr. R..H. Engelken
~
r ftRC Operations Office J
%.C I;I Region V rd 1990 florth California Boulevard R.
y'i3 C
Walnut Creek Plaza, Suite 202 w'
o'
??
Walnut Creek, California 94596
}
Re: Operating License DPR-54 Docket No. 50-312
~
Reportable Occurrence 78-3
Dear Mr. Engelken:
y t
U/
In accordance with Technical Specifications for Rancho Seco Nuclear Generating Station, Section 6.9.4.2.b, the Sacramento Municipal Utility District is hereby reporting the following as Reportable j
Occurrence 78-3.
)
i In compliance with Technical Specifications, Section 4.14.1, the visual inspection of " inaccessible" safety system hydraulic snubbers was being performed on March 20, 1978.
During that inspection, one of the 77 snubbers in the " inaccessible" category was found to be low on fluid.
No evidence of leakage was found on or_ near the snubbers. The unit had an acceptable fluid level when checked during the last visual J.,
inspection and no obvious oil leakage was present. The fluid reservoir was filled to the proper level, returned to service, and the in-spection interval shall be increased to twelve months in accordance with Technical Specifications, Section 4.14.1.
The snubber, identified in Table 4.14-1 as List Number SS-20, is Bergen-Patterson Model HSSA-70-6 unit. The unit supports the redctor coolant pump B casing.
There was no plant transient or shutdown associated with
'~
this occurrence.
2; Respectfully submitted, 0
. /%
7,.7
- J. J. Mattimoe 4
Assistant General l'anager and Chief Engineer-
~~
Attachment 9
cc:
Director, MI.C (3) 8003250 3
Director, IE (30)
Ai tr. c:as: s y s T E v s c en : c u c a t 8 4.'. ic:.:ce,n in t. s taa t o r A tt r o.P n ; A
~
5, e
A, 4
1 J
J y oa k ass u.s.Nuct An necutarony contssics
).
i.fCENSEE EVENT REPORT I
CONTROL SLCCE: 1 l I i 1 1 EXHIBIT A,
l 3
(PtgAss pn:Nr CR TYPE ALL REQUI Ato INFoRMArtCNS
@ lClA lRI SI5l I!@ al0l0101010Dl010l010f0'l@l411l1III1l@l I l t
,,m,A@
mom.cm.
m. s..,.....
m u....,...
- - r i
f~T 1 E7d [L,,j@l Of ti I O10 ! O 11 I 1 I 2 l@l 0 il i 2 l Of 7 f8 @l 01411 I 717 I 8 l@
e 42
- ,,:.4r via.
= +,
n or are a
a apar are 44 sysNToasenseries ANo,*:sAste c:.steusNets @ i fications Section 4.14.1, the periodicI.
in accordance with-Technical Spec rT11 j
t-~rri tvisual insoectien of " Inaccessible" safety system hydraulic snubbers was 1
^
r: r.1 Perforced on March 20, 1978.
One snubber, List ilo. 55-20 Table 4~.14-1, i
- p.,,, pas found low on fluid and required refilling to be returned to operability.
g IThe snubber had a oroner fluid level at the last visual inspection and
- ! l rrrt w u.., m,. v...n o -.97 I
q wI y
- s t
,0
?.
'c!?/
TE!
sS$a sc.iEr s" Weir d
ca.e =~wrecos l C IS l@ [Lj@ 12 l@ l SIU l P IO ! R l Tl@ Q@ Q @
1:!91 9
a4 11 to 13 iS is u
s 6
stoutNTial CCc;patsCE gn, pt *0,.t?
"Evi8 ION tyt%fvram AUCM? %3.
CQQf
@lgge oggg; 1718 l TV g
- peg,
.)y I
10 p 0121 y
101 3; l L; g
g d
2.
as a
u -
u u
v u
a u
2.
n
= ',w a:s sww s, s ',7.'nw.t:=, ";;'I"ir
.. z**iT":,..
[Xj@lX_j@ 1 Il@ ' (_Z]@
2 f
10101 0F0 I W@
L'ij@ l l@
la i sg r
u g ; !!o evidence of leakage coul @ce detected either on the snubber or on any cause osscairrion u.o cenarenva.r.: n:Ns E l_ comoonent near the snubber.
Given the historv. of the snubber, no cause i.
Q Icould he determined.
The snubber was refilled and, in accordance with s
2 W ITechnical Speci fications Section 4.14.1. the sur.veillance interval has I
b t m t een increased to twelve" months.
i,
. 1 ST 4 LPon1R OD8 Ems 7ATUS bi 00 OtsCQvtR, DESCRi.TTOM h v
@l 10 @ NA I IB @ @
l 1,1 he
- Jny,,,
3..ty..@.e.ih.ym, s,...c,vi, @,~
..,,A., @
a u
e.n
=
L j 1._j$1 ilA l
l flA l
- n d*t.o,esS,u : net...rie, @.
. w.eus m
$[01010 !@[Zj@! NA I
- n.se.al'av.h
, Q [0Ydy0 Jgl"""
Mhh k
l
-]
4 e i,
i:
jWW e u uu w r
gos ce c= na.g.aciurv g
.o 5I
( }a fA
., ~
v/
.s-. ':uso: nma..ne,On sa
\\
Nac use cNLY d W,i,I t.ncal newspacers and w.e re services noti fied g giirri:ri il s 9 o
~
a e,
sa R. V. Color bo (916) 452-3211 a
~
NAa:tose.g,Anta
,,oy,.
Pod 2No7Cy
-