APPENDIX 2I 1,

SEISMOIDGY i

BY: WESTON GEOPHYSICAL RESEARCH, INC.

I I

!O f

i I

I, 3

I l

015?

O

WESTON GEOPHYSICAL RESEARCH, INC.

-P9f

','{

POST OFFICE BOX 304 WESTON, M ASSACHUSETTS 02193

~ A RE A CODI, 6tf 894.toin

~

June 27,1967 Mr. Richard E. Wright Gilbert Associates, Inc.

525 Lancaster Avenue Reading, Pennsylvania

Dear Mr. Wright:

We submit herewith our final report of the Seismicity Analysis and Response Spectra for the proposed Crystal River Nuclear Power Plant in accordance with your Purchase Order Number 155095 dated April 28, 1967.

The Reverend Daniel Linehan, S.J., Director of Weston Observatory, acted as a consultant on the seismicity phase of this report.

The Response Spectra was completed by Dr. C. Allin Cornell, Department of Civil Engineering, Massachusetts Institute of Technology.

Sincerely, WESTON GEOPHYSICAL RESEARCH, INC.

Richard J. Holt RJH:mrm Enc.

0153

.O

_.