ML19319D249
| ML19319D249 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 11/30/1975 |
| From: | Albersheim S NUS CORP. |
| To: | |
| References | |
| NUS-1554, NUDOCS 8003130875 | |
| Download: ML19319D249 (150) | |
Text
{{#Wiki_filter:__---------7 i lc THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE OFFICE OF REGULATION. THEY HAVE l E' DEN CHARGED TO YOU FOR A LIMITED TIME PERIOD ANS MUST BE RETURNED TO THE CENTRAL RECORDS STATION 008. ANY PAGE(S) REMOVED FOR REPRODUCTION MUST BF RETURNED TO ITS/THEIR ORIGINAL ORDER. DEADLINE RETURN DATE d ll 'LI 'L5 2 P i O o 1 x G: 30-3Ob Q q - - M95' Ei u ang 4 L
- g l,
p' MARY JINKS, CHIEF CENTRAL RECORDS STA lON /3 06 g$ 1
1 NUS-1554 CRYSTAL RIVER UNIT 3 Interim Six-Month Meteorological Report January 1,1975 - June 30,1975 By Steven R. Albersheim November 1975 NUS Corporation 4 Research Place Rockville, Maryland 20850 Environmental Safeguards Division ~M' x g1_ Tohn H. Taylor, " \\J. J. DiNunno,
- Manager, Vice President & General Manager Meteorological Programs Environmental Safeguards Division 4
e um ?-e=
.7 . i TABLE OF CONTENTS Pace I. INTRODUCTION II. DATA SOURCES 2 III. DATA RECOVERY AND DATA REDUCTION 3 IV. METEOROLOGY 5 A. Wind Direction and Associated Average Wind Speed 5 B. Atmospheric Stability' 6 i V. SHORT-TERM-(ACCIDENT) DIFFUSION ESTI5tATES 7 A. Discussion 7 B. Models 9 References 12 Appendices A - Monthly and Six-Month Joint Frequency Distributions of 33-ft Wind Speed and Wind Direction for Each and Combined Stability Classes Based on AT 175 ft-33 ft B-Monthly and Six-Month Joint Frequency Distributions of Wind Speed and Wind Direction for Each and Combined Sta-bility Classes Based on og or the 33-ft f Level C - Monthly and Six-Month Joint Frequency Distributions of Wind Speed and Wind Direction for Each and Combined Sta-bility Classes Based on og for the 175-ft Level 4. 1 i
LIST OF TABLES Table No. Title Pace No. I Onsite Monthly Data Recovery (January 1, 1975 - June 30,1975) 14 II Stability Categories Based onog 15 III Stability Categories Based on AT 16 IV Crystal River Onsite, Monthly Mean Wind Speed at the 33-ft and 175-ft Levels and Tampa International Airport, Florida (January 1,1975 - June 30,1975) 17 V Crystal River Monthly and Six-Month Dis-tribution of Stability Categories Based on Onsite a6 with Associated Mean Wind Speed at the 175-ft and 33-ft Levels (January 1,1975 - June 30,1975) 18 VI Crystal River Monthly and Six-Month Distri-bution of Stability Categories cased on Onsite AT Data with Associated Mean Wind SpN b~ Neb 3-ft Level (January 1,1975 - June 30,1975) 19 VII Crystal River Cumulative Frequency Distri-d bution of Accident X/O (sec/m ) Values Based on 6T a 1,19g5_ffu!! b,nd 33-ft Wind Data (January 1975) 20 VIII Crystal River Cumulativg Frequency Distribution of Accident X/Q (sec/m ) Values Based on 06-33 ft Wind Data (January 1,1975 - June 30,1975) 21 IX Crystal River Cumulativg Frequency Distribution of Accident X/Q (sec/m ) Values Based on AT and Onshore Wind Flow for the 33 [t L$vb ffanuary 1,1975 - June 30,1975) b 22 X Crystal River Site Boundary Distances (January 1,1975 - June 30,19 75) 23 4 11
LIST OF FIGURES Figure No. Title 1 Location of 175-ft Meteorological Tower at Crystal River 2-Crystal River 33-ft Monthly Wind Roses with Associated Mean Wind Speeds Ganuary 1,1975 - June 30,1975) 3 Crystal River 175-ft' Monthly Wind Roses with ' Associated Mean Wind Speeds (January 1,1975 June 30,1975) 4 Monthly Wind Roses with Associated Mean Wind
- Speeds for Tampa, Florida (January 1,1975 -
June 30,1975) 5 Crystal River 33-ft and 175-ft Level and Tampa Six-Month Wind Roses with Associated Mean Wind Speeds Ganuary 1,1975 - June 30,1975) f f 6 111 ,c er,..
I.. INTRODUCTION The Crystal River Unit 3 FSAR meteorology sections were based on site data collected for the period January 1,1972 - December 31,1972. Since this data period, Florida Power Corporation has installed a new meteorological monitoring facility meeting the requirements of Regulatory Guide 1.23 This interim report presents a summary of onsite meteorological data used to esti mate short-term diffusion factors for the data period January 1,1975 - June 30,-1975. Joint data recovery rate of AT a w a a Was percent. 175 ft-33 ft Comparison of onsite wind data for this report period to concurrent National Weather Service (NWS) data for Tampa, Florida, indicates a general agreement. The 5th percentile hourly X/Q yalue for the exclusion radius (1340 m) based on stability determined by 6T is 2.3 x 10 sec/m and for stability 175 ft-33Jt determined by ad-33 ft is 8.7 x 10 sec/m for the six-month period January 1, 1975 - June 30,1975. By way of comparison, the 5th percentile X/Q value -4 based on stability determined by ad-35 ft is 1.8 x 10 sec/m for the 12-month period January 1,1972 - December 31,1972, which is approximately twice the 5th percentile X/Qvalue based on the data period January 1,1975 - June 30,1975. (Note that direct comparison of the 5th percentile X/Q values based on six-month data to those based on 12-month data should be made with caution.) 1 v
II. DATA SOURCES Onsite meteorological data for the period January 1,1975 - June 30,1975 were used in this report. The data were taken from a 175-ft guyed meteo-rological tower located approximately 2216 ft southwest of Unit No. 3,as shown in Figure 1 The base of the tower is at an elevation of approximately 8 ft MSL. The topography in the site area is extremely flat and featureless.. The location of the meteorological tower is considered to be in an area that is meteorologica11y representative of the site region. The topography 'in the area of the reference NWS station is similar to the terrain' at Crystal River. A de-tailed description of the meteorological monitoring facility is provided in " Meteorological Monitoring System Description Crystal River Unit 3".( } A description of the old meteorological system is presented in the Crystal River Unit 3 Nuclear FSAR (Docket No. 50-302). The starting threshold of the Bendix Aerovane used for the 1972 data period was approximately 1.9 mph, whereas the present C11 met wind speed sensor has a threshold value of 0.6 mph. ( 3 ) Other meteorologi* cal data are presented for the NWS station located at Tampa International Airport, Florida.(4) The NWS station at Tampa is located ap-proximately 75 miles south of the Crystal River site at t.n elevation of 19 ft MSL, with the wind sensor at 22 ft AGL. Surface wind data used in this re-port for Tampa are based on the six-month period January 1,1975 - June 30, 1975, and were obtained on magnetic tape from the National Climatic Center, Asheville, North Carolina. 2
~ III. DATA RECOVERY AND DATA REDUCTION Monthly onsite meteorological data recovery rates for the Crystal River meteorological program for the period January 1,1975 - June 30,1975, are listed in Table I. The data recovery for all meteorological parameters exceeded 90 percent for the report period. The joint data recovery for the ' 67 and 33-ft wind data was 94 percent. 175 ft-33 ft The Crystal River Unit 3 Meteorological Monitoring Facility includes a digital and analog recording system. Only the analog recorded data are included in this report. For this report hourly averages centered on the hour were cbtained for 6T data. Average values of wind speed and direction were 175 ft-33 ft obtained from 15-minute samples of analog wind data centered on the hour. The standard deviation of the wind direction fluctuations (og) is obtained by dividing the wind direction range for the 15-minute period by a constaat of 6.0 as follows: 5) A1+A2 "6 " (Eq. 1) 6 where: 1 6 ~O I Omax> Oavg A = max avg 360 + 6 A 0 1 6 max < O = 1 avs avg A O ~Omin' Omin < O 2 avg avg 0+6 O Omin > O A = ~ 2 avg min avg 2nd highost peak - e = max '2nd highest peak e = average wind direction 6 = g 3
~ ? Atmospheric stability data based on g data are classified into stability o categories "A" through "G" according to Table II. (6) Calm con-ditions (15-minute sample average wind speed of <0.6 mph) are classified into an."E" stability category if they occur during the night and into a "B" cate' gory if they occur during the day. Atmospheric stability, based on the temperature lapse rate, is classified i according to Table III. The temp'erature lapse rate in F/1000. ft is de-termined from AT data as follows: (1000) AT AT(o /1000 ft) = 175 ft-33 ft F 3g (Eq. 2) 175 ft-33 ft - where: AT175 ft-33 ft = difference in ambient temperature between the 175-ft level and the 33-ft level, F az = vertical distance between the two levels of l75 ft-33 ft temperature instrumentation,142 ft.. Monthly'and six-month joint frequency distributions of wind speed and di-i rection by atmospheric stability based on AT are presented in 175 ft-33 ft Appendix A. Monthly and six-month joint frequency distributions of wind - speed and direction by atmospheric stability based on a6 or the 33-ft and f 175-ft levels are presented in Appendices B and C, respectively. f 4
IV. METEOROLOGY A. Wind Direction and Associated Average Wind Soeed Monthly wind roses with associated average wind speeds for the 33-ft and 175-ft levels derived from onsite measurements for the period January 1,1975 - June 30,1975, are presented in Pigures 2 and 3. The prevailing wind during - the six-month period is from the west.at the 33-ft level and from the west-northwest at the 175-ft level. Figure 4 presents the monthly wind roses with the associated average wind speed for the NWS station at Tampa, Florida, for the same period. Figure 5 presents the six-month wind roses for the 33-ft and 175-ft levels and for Tampa. The Tampa wind roses show distributions of wind direction similar to onsite wind data for both the 33-ft and 175--ft levels. Monthly mean wind speeds for onsite data for the 33-ft and 175-It levels for the report period are presented in Table IV. Monthly mean wind speeds for NWS data for Tampa are also presented in Table IV. These data compare fa-vorably. The frequency of calms based on six months of onsite data is 0.10 percent at both the 33-ft and 175-ft levels. The frequency of calms for concurrent NWS data for Tampa is 5.0 percent. The NWS station wind speed sensor has a starting threshold of approximately 3.5 mph as compared to 0.6 mph for Crystal River Climet wind speed sensors. } The higher frequency of calms at Tampa is attributed to the higher starting threshold of the NWS wind speed sensor. 5
B. Atmosoheric Stability Stability classifications based on standard deviation of wind direction fluctua-tions (og) are presented in Table II. Those based on temperature lapse rates (AT) are presented in Table III. Both classification schemes are taken from Regulatory Guide 1.23.(6) Monthly and six-month average distributions of onsite 33-ft and 175-ft sta-bility classes based on og and the associated average wind speeds' for Crystal River are presented in Table V. These data indicate that neutral,and slightly stable conditions at both the 33-ft and 175-ft levels are predominant. The monthly joint frequency distributions of wind speed versus wind direction by stability class based on g for 33-ft and 175-ft wind data are presented in Appendices B and C, respectively. Monthly and six-month average distributions of stability categories based on AT with associated average 33-ft wind speed data are presented in 175 ft-33 ft Table VI. Neutral and slightly stable conditions are predominant onsite. The joint frequency distribt.tions of wind speed versus wind direction by stability class based on AT are presented in Appendix A. 175 ft-33 ft 6 e-
V. -SHORT-TERM (ACCIDENT) DIFFUSION ESTIMATES A. Discussion Onsite data from the Crystal River site were used to derive atmospheric dif-fusion estimates for accidental releases of effluents to the atmosphere. Cumulative frequency distribut' ions for X/Q values for stability classifica - tions based on both the AT and the og approaches were calculated for time in-tervals of 1 hr, 2 hr, 8 hr,16 hr, 72 hr (3 days), and 624 hr (26 days). Calculations were made for all wind directions for the exclusion, boundary distance (1340 m), site boundary distances,and at the low population zone (8047 m) for appropriate time periods based on onsite data for the period January 1,1975 - June 30,1975. Calculations of X/Q values based on6T were also made excluding offshore winds (southeast counterclockwise through north-northwest) for the exclusion boundary distance and the low population zone. Tables VII, VIII, and IX summarize the cumulative fre-quency distributions for AT stability classifications, a6 stability, and onshore winds, respectively. Table X presents the closest site boun-dary distance for each 22.5 sector. For the exclusion boundary distance, the hourly 5th percentile X/Q value based on stability determined by AT f r all wind directions is 175 ft-33 ft 2.3 x 10 sec/m. By way of comparison, the same parameter calculated ~ for onshore winds only is 7.0 x 10 sec/m. The 5th percentile X/Q value based on stability determined by a6-33 ft r al w n d as is 8.7 x 10 -4 sec/m, which compares to 1.8 x 10 sec/m based on ad-35 ft wind data for the period January 1,1972 - December 31, 1972 7
The differences in the X/Q values in Tables VII and VIII are due to differences'in methods for determining stability classifications, as discussed in Section III. Examination of the Joint frequency of wind speed versus wind direction by atmospheric stability based on AT (Appendix A) and the joint frequency of wind speed versus wind direction by atmospheric stability based on og-33ft (Appendix 9) indtcates that,for stability based on AT, the Join't frequency of occurrence of wind speeds equal to or less than 3.5 mph (including calms) associated with moderately stable and extremely stable conditions (F and G) was 4.6 percent versus 0.7 percent for stability determined by og. Therefore, lower X/Q values would be expected using the g approach. The difference in the 5th percentile X/Q values based on "6 f r the period January 1,1972 - December 31,1972,and January 1,1975 - June 30,1975, is attributed to the following. Due to differences in meteorological instru-mentation,the frequency of calms for the period January 1,1972 - December 31,1972 was 2.9 percent at the 35-ft level,whereas for the period January 1, 1975 - June 30,1975, there was only 0.1 percent occurrence of calms at the 33-ft level. The frequency of calms and wind speeds equal to or less than 2.5 mph for the 1972 data was 10.7 percent as compared to 2.5 percent for the six-month data period. More specifically, a higher frequency of calms and low wind speed conditions associated with E, F, and G stability conditions determined by og for the 35-ft level for the period January 1,1972 - December 31, 1972, was observed than at the 33-ft level for the six-month period January 1,1975 - June 30,1975. There was a 6.8 percent occurrence of winds (including calms) equal to or less than 2.5 mph associated with E, F, and G stability conditions bas _ on "6 wind data for the period January 1,1972 - December 31,1972, whereas there was only 1.0 percent occurrence of winds equal to or less than 2.5 mph (including calms) associated with E, F, and G sta-bility conditions for this report period. In addition, the minimum cross-sectional 8 een s 3
y '[. /Q values for the area of the containment used in computing percentile X1850 m, where 31,1972, was period January 1,1972 - December t) was (the currently accepted minimum cross-sectio ~ 5 used for this report. values for the 1975 data. /Q value There remains the question of the representativeness of X h June 30 h calculations for the six-month period from January 1 t roug The results,of a study unddr-to those expected for a full year of data. X/O values to, deleting taken to assess the sensitivity of the 5th percentilethat one can portions of a calendar year's data reveal h June data to under-h the 5th percentile X/Q values based on January t roug by about 5 percent.(9 estimate the X/Q value based on the full calendar year pproximately It was shown that in one case (out of 14) the underes l The results of the study applied to the Crystal River X/Q c fidence the 5th percentile X/Q 22 percent. lations indicate that with about 50 percent con d 2.4 x 10'4 sec/m 3 value based on a full year (1975) data would not excee ~4 3 d 3.0 x 10 sec/m, and with about 90 percent confidence it would not excee Models B. d f ground level Centerline calculations of dilution factors (X/Q) wer releases using a Gaussian model, which includes abuilding wake effe the additional initial diffusion resulting from thed to reduce any Inclusion of the building wake factor (cA) was nct allowe f t of 3. Centerline calculated center 1tne X/Q value by more than a ac or using the X/Q values were computed for periods of 1, 2, ano 8 hr following equation: 1 (Eq.3) ~X/Q=(tra a+cAjii l y 9
a a + where X/Q = concentration Y normalized to source strength Q, seconds per.ubic meter a,a = horizontal and vertical dispersion parameters, meters y z u = the mean wind speed, meters per second c- = the building shape factor (0.5), dimensionless A = the minimum cross-sectional area of the containment building, 2030 squhre meters. Sector-everage (22.5 sectors) calculations of x/Q values were,made for ground level releases for periods of 16, 72, and 624 hr. Because of the longer time periods, the wind was assumed to meander, resulting in the effluents be-coming uniformly dispersed horizontally throughout the 22.5 sector. The following equation was used: x/g = 2.032 o ux g (Eq. 4) where x is the downwind distance in meters and the other variables are as given for Equation 3 Wind data used in the calculation were taken at the 33-ft level, and atmospheric stability was determined by AT175-33 ft Y %-33 ft wind data. The values of h .t e horizontal and vertical atmospheric stability parameters a and a were Y Z based on curves developed by Hilsmeier and Gifford.(13) A seventh curve representing very stable conditions (G) was added by NRC based on work by Yanskey et al.(14) Observations of calms were assigned the wind direction of the first noncalm observation that followed and were assigned a wind speed of 0.25 mph. A set of 4,086 valid hourly observations out of a possible total ' of 4,344 observations was used to represent the period. The data were collapsed around missing observations and linked end to beginning to form an endless cycle. 10 .1
In calculating the cumulative frequency distribution of X/Q values for onshore winds only, the hourly calculated X/Q values for offshore winds were set to zero. Cumulative frequency distributions of Y/Q values, as presented in Tables VII, VIII, and IX, were obtained using the following procedures for each in. terval period: 1) The hourlyX/Q values were computed at the required distances for each hourly observation, either all cen-terline or all sector-average. 2) The interval was allowed to begin at each of the hourly observations in the cycle. 3) For each interval start time, the interval-average X/Qvalue in each of the 16 directions was computed and the maximum interval-average X/Qvalue was stored in a master file. 4) After obtaining a complete set of maximum interval-average values of X/Q (one per possible start time), the values were then ranked from the highest to lowest and the required per-centile values were selected. The exclusion zone e <tends outward to a distance of 1340 m in all directions, and the low population zone (LPZ) to a distance of 8047 m. 4 11
REFERENCES 1 Letter from Mr. Joel Rodgers, FPC, to Mr. A. Schwencer, NRC, September 17, 1974. 2. Crystal River Unit 3 Nuclear, FSAR, Vol.1 (Docket No. 50-302) Amendment 34, November 15, 1973. 3 Mazzorella, Daniel, "An Inventory of Specifications for Wind Sensoring Instruments," Bulletin of the American Meteorological Society, 53(9) (1972). 4 Local Climatological Data, Monthly Summary (January - June,1975) National Oceanic and Atmospheric Administration, Environmen'tal Data Service. 5. Markee, E. H., "On Relationships of Range to Standard Deviation of Wind Fluctuations," Monthly Weather Review, R(2) (1963). 6. Regulatory Guide 1.23, "Onsite Meteorological Programs," USNRC, February 17, 1972. 7. Slade, D. H., " Dispersion Estimates from Pollutant Releases of a Few Seconds to Eight Hours in Duration," Tech. Note 2-ARL-1, ESSA,19 65. 8. Personal communication with Daryl Martin, meteorologist, at the NWS station, Tampo, Florida, on October 28, 1975. 9. Woodard, Keith, " Sensitivity of Atmospheric Diffusion Estimates to Meteorological Data Recovery and Accuracy," Nuclear Tech-nology, 25 (1975). 10. Slade, D. H., Meteorology and Atomic Energy. USAEC,1968, Section 3-3.5.2 11 Regulatory Guide 1.4, " Assumption Used for Evaluating the Po-tential Radiological Consequences of a Loss of Coolant Accident for Pressurized Water Reactors," USNRC, June 1973 12. Gifford, F. A., " Atmospheric Dispersion Calculations Using the Generalized Gaussian Plume Model," Nuclear Safety, 2 (December 1960). 13. Hilsmeter, W. F., and F. A. Gifford, Graphs for Estimating At-mespheric Dispersion, USAEC Report ORO-545, Weather Bureau, Oak Ridge, Tennessee,1962 12
REFERENCES (cont'd) Yanskcy, G. R., E. H. Markee, and A. T. Richter, Citma_- toloov of the' National Reactor Testino Station, Environmental . 14. Sciences Services Administration, IOD-12048, Figures 3 -4, 1968. O 9 e O O e J t 13
TABLE I CRYSTAL RIVER 9 ONSITE MONTHLY DATA RECOVERY (January 1,1975-June 30,1975) Data Recovery (%) I int AT175 ft-33 ft AT Month 33-ft Wind 175-ft Wind and 33-ft Wind 17$ ft-33 ft January 99 91 99 99 February 92 98 92 99 ~ March 80 95 80 99 April 97 92 97 99 h4ay 98 98 98 99 4 June 99 98 98 99 January-June 1975 94 95 94 99 i ) i 14
TABLE II STABILITY CATEGORIES BASED ON% Range of Standard Deviation, Degrees' Turlyllence Type Stability Class Extremely Unstable a6 2 22.5 A = > 17.5 High Atmospheric Unstable
- 22. 5 > og B
= Turbulence Slightly Unstable
- 17. 5 > og
> 12.5 C = Neutral
- 12. 5 > og 7.5' Moderate Atmospheric D
= g Turbulence Slightly Stable 7.5 > a6 3.8 E =- Stable
- 3. 8 > og 2
2.1 Low Atmospheric P = Turbulence Extremely Stable 2.1 > a G = s g
- Derived from Reg. Guide 1.23(6)
O E
a -. TABLE III STABILITY CATEGORIES BASED ON AT Range of Vertical Temperature Cradient ( C/100 m) Turbulence Type Very Unstable AT -1.9 A = Moderately Unstable -1.9 5 AT -1.7 High Atmospheric 3 = Turbulence S!!ghtly Unstable -1.7 I AT~ -1.5 C = Neutral -1.5 5 AT -0.5 Moderate Atmospheric l3 = 'Turbule-
- Slightly Stable
-0.5 s AT l.5 E = Modcrately Stable 1.5 $ AT 4.0 Low Atmospheric ? = Turbulcr.ce Very Stable 4.0 s AT ,G = l Range of Vertical Temperature Gradient ( F/1000 ft) Turbulence Type Very Unstable AT -10.4 A- = Moderately Unstable -10.4 5 AT - 9.3 High Atmospheric B .= Terbulence Slightly Unstable - 9.3 5 AT - 8.2 C = Neutral - 8.2 5 AT < ~- 2.7 Moderate Atmospheric D = Turbulence Slightly Stable - 2.7 5 AT 8.2 E = Moderately Stable 8.2 $ AT 22.0 ? Low Atmospheric = Turbule:.ce Very Stable 22.0 $ AT G = .r" O
.) TABLE IV CRYSTAL RIVER ONSITE MONTHLY MEAN WIND SPEED AT THE 33-ft AND 175-ft LEVELS AND TAMPA INTERNATIONAL AIRPORT, FLORIDA (January 1,1975-June 30,1975) Wind Speed (mph) Month 33 ft 175 ft Tampa * - January 8.8 12.8 8.2 February 8.5 12.3 8.1 March 9.6 14.1 9.1 April 8.6 12.4 9.2 May 7.4 10.8 7.9 June 7.2 10.3 7.4 January-June 1975 8.3 12.1 8.3
- Based on monthly LCD's for Tampa, Florida.
The wind sensor at Tampa is at 22 ft AGL. 17
{.
- s c
TABLE V - CRYSTAL RIVER MONTHLY AND SIX-MONTH DISTRIBUTION OF STABILITY CATEGORIES BASED ON ONSITE og -WITH THE ASSOCIATED MEAN WIND SPEED AT THE 175-ft and 33-ft LEVELS (January I',1975-June 30,1975) %) A a G H E E 9. Tomo v 175 ft 5 0.30 0.89 2.37 14.22 40.00 25.78 16.44 mph 5.1 9.6 7.2 Io 3 12.8-14.7 12.9 33 ft % 0.27 1.21 5.40 33.uA 48.40 9.99 1.G2 mp's 8.7 5.0 '7.0 ..t 10.0 7.2 4.4 February 175 ft % 0.30 .06 3.78
- 10.88 37.76 30.36 15.66 mph 16.9 5.0 8.0 8.6 11.8 14.2 13.7 33 ft %
1,46 2.10 11.17 32.85 46.44 5. 3 -) 0.65 mph 6.2 5.2 6.7 8.5 9.7 4.9 4.0 March 175 ft % 0.28 0.99 3.55 16.88 32.77 30,.35 15.18 mph 3.5 6.1 11.8 11.3 14.5 15.4 14.9 H 33 ft % 1.01 3.03 13.64 40.91 37.88 3.03 0.51 mph 5.5 8.3 8.5 10.3 9.6 7.7 4.3 Acril 175 ft % 0.76 0.91 6.05 30.56 46.44 11.95 J.33 mph 6.2 6.3 8.9 11.4 13.7 13.0 11.1 33 ft % 1,43 6.14 22.71 57.14 12.43 0.14 0.00 mph 5.6 8.1 9.4 9.0 6.1 6.0 0.0 May 175 f t % 0.96 1.51 7.00 34.71 42.11 9.33 4.39 mph 4.6 6.3 7.9 10.1 12.2 10.3 10.8 33 ft % 2.47 9.73 32.19 41.51 13.42 0.68 0.00 mph 4.0 8.1 8.4 7.5 4.7 3.6 0.0 Inne 175 ft % .l.41 2.26 10.03 42.51 32.34 .7.34 4.10 mph 5.5 6.7 7.7 9.9 12.2 9.7 9.5 33 ft % 2.37 14.92 33.19 37.80 10.88 0.70 0.14 mph 4.6 8.0 8.3 6.7 4.8 4.5 1.8 January - June 1975 175 ft % 0.68 1.28 5.51 25.19 38.52 19.03
- 9.80 mph 6.0 6.6 8.4
^10.3 12.9 13.9 13.1 33ftW 1.51 6.37 20.05 40.61 27.66 3.32 0.49 mph 5.0 7.8 8.4 8.3 8.7 6.5 4.2
y d TABLE VI CRYSTAL RIVER MONTHLY AND SIX-MONTH DISTRIBUTION OF STABILITY CATEGORIES BASED - ON ONSITE AT DATA WITH THE ASSOCIATED MEAN WIND SPEED 17Sft-33kk THE 33 ft LEVEL'- (January 1,1975-June 30,1975) . AT A n c n E r. G-January 14.56 0.81 4.58 33.29 27.09 10.78 8.89 mph 10.9 10.7 9.1 10.1 8.5 5.5 5.1 l'ebruary % 18.93 2.10 4.85 29.94 23.62 11.97 8.58 mph 10.3 8.2-8.3 10.1 8.4 4.8 4.8 March 55 23.48 3.21 4.90 27.53 27.70 7.43 5.74 mph 11.2 10.0. 10.4 10.8 8.5 .5.8 4.8 April 15.74 3.00 5.44 26.75 34.19 10.73 4.15 ~ 9 mph 10.4 10.5 10.5 10.0 7.7 5.7 4.5 May 21.40 2.88 5.49 24.69 24.42 16.05 5.08 mph 9.7 10.0 8.3 8.3 .6.3 4.6 3.9 June 17.35 2.40 5.36 22.57 34.27 15.23 2.82 mph 9.3 8.9 7.9 7.7 6.6 4.8 4.4 January 18.42 2.37 5.11 27.44 28.64 12.18 5.84 June 1975 mph 10.3 9.7 .9.1 9.5 7.6 5.1 4.7 a e
s h^ 'I TABLE VII CRYSTAL RIVER ^ CUMUpTIVE FREQUENCY DISTRIBUTION OF ACCIDENT X/Q (sec/m ) VALUES BASED ON AT175ft-33ft ^ ^ (January 1,1975-June 30,1975) Probability cf Exclusion Distanco Low Population Zone Y/Q 2 Indicated Radios of 1340 m Site Roundary nMt. vees 8 34 7 r-(t ) Hourly 2 Hr Hourly 2 Hr 8 Ilr 16 I!r 3 Deys 26 Days -6 4.84x10 3.23x10 8.56x10~ 3.81x10~ Worst Case -4 -4' -6 5 2.32x10" 1.65x10 1.34x10 1.01x10 'l.40x10-1.40x10 G.29x10~ 3.34x10" -4 10 1.55x10 1.16x10- '8.68x10 6.66x10~ 9.36x10~ 1.06,x10" 5.66x10' 3.15x10- ~0 20 8.07x10~ 6.46x10" 4.77x10 3.67x10 4.97x10 7.72x10~ 4.79x10~ 2.91x10~ ~ -5 -5 30 5.34x10~ 4.09x10-3.03x10 2.52x10 3.29x10' 5.95x10~ 4.33x10-2.75x10' -5 -5 40 3.75x10~ 2.96x10-2.18x10 1.80x10 2.27x10~ 4.76x10~ 3.85x10' 2.48x10 ~ -5 -6 50 2.69x10~ 2.16x10~ 1.68x10 1.32x10~ 1.54x10 4.08x10~ 3.09x10~ 2.31x10~ -5 -5 -6 60 2.02x10-1.61x10 1.17x10 9.93x10 1.13x10' 3.38x10~ 2.59x10~ 2.12x10" 70 1.34x10-1.14x10~ 7.56x10 6.56x10 8.48x10N 2.79x10~ 2.23x10~ 1.95x10~ -6 -6 4 e a e
S .i'I-TABLE VIII CRYSTAL RIVER. CUMULATIVE FREQUENCY DISTRIBUTION OF ACCIDENT 3 DATA - X/Q (sec/m ) VALUES BASED ON"d-33ft (January 1,1975-June 30,1975) Iow Population Zone , Probability of Dcclusion Distence X/Q2 Indicated Radius of 1340 m Site Boundary Distr.nces 8047 m (*4) Houriv 2 Hr Hourly 2 Fr 8 Hr i 16 Hr 3 Days 26 Days 1.99x10~ 1.42x10~ 4.83x10~ 2.07x10~ Worst Case ~ 5 8.72x10" 6.98x10 5.25x10~ 4.05x10~ 4.60x10~ 8.96x10~ 3.52x10 1.90x10 -5 10 6.72x10~ 5.09x10~ 3.77x10 2.93x10~ 2.94x10" 5.68x10~ 3.19x10~ 1.67x10 -5 20 -4.63x10" 3.47x10 2.59x10~ 2.09x10~ 1.93x10~ 4.24x10 2.60x10~ 1.59x10~ ~ -5 30 3.47x10 2.77x10~ 2.06x10 1.62x10~ 1.53x10~ 3.56x10~ 2.43x10~ 1.50x10" -5 ~ 40 2.69x10~ 2.24x10 1.65x10~ 1.31x10 1.30x10~ 3.05x10 2.07x10~ 1.43x10 -5 ~ 50 2.30x10~ 1.83x10~ 1.28x10~ 1.08x10~ 1.06x10~ 2.67x10~ 1.81x10 1.33x10~ ~ ~ 60 1.79x10~ 1.49x10~ 1.01x10 8.48x10 8.70x10~ 2.39x10 1.54x10~ 1.20x10 ~ ~ -5 -6 ~ 70 1.36x10~ 1.15x10~ 7.31x10~ 6.19x10~ 6.9 0x1,0 2.09x10 1.37x10" 9.77x10 ~ ~ 0 8 e
~ TABLE IX CRYSTAL RIVER '- . CUMULATIVE FREQUENCY DISTRIBUTION OF ACCIDENT X/Q (sec/m ) VALUES . BASED ON AT AND ONSHOE WIND MW FOR THE 33ft LEE 175ft-33ft (January 1,1975-June 30,1975) Probacility of Exclusion Distance Low Population Zone - X/Q > Indicated Radius of 1340 m 8047 m 'N Hourly 2 Hr 8 Hr 16 Hr 3 Days-26 Days 4.84 x 10~ 3.23 x 10" 8.10 x 10~ 3.05 x 10~ Worst Case -6 5- '6.95 x 10~ 6.71 x 10~ 5.38 x 10 7.56 x 10" 4.75 x 10" 2.86 x 10" 10 5.34 x 10~ 4.05 x 10" 3.27 x 10" ' 5.68 x 10~ 3.79 x 10~ 2.59 x 10' N 20 2.96 x 10~ 2.65 x 10 1.66 x 10~ 3.'79 x 10~ 2.44 x 10~ 1.93 x 10" ~ 30 1.98 x 10~ 1.63 x 10' l.15 x 10" 2.83 x 10~ 2.06 x 10 1.54 x 10' ~ ~ 40 8.23 x 10~ 1.09 x 10~ 8.43 x 10~ 2.25 x 10" 1.84 x 10~ 1.19 x 10 ~ SO 2.20 x 10~ 3.40 x 10~ 6.10 x 10' l.89 x 10~ 1.56 x 10~ 9.85 x 10 60 0 1.26 x 10" 4.10 x 10~ 1.48 x 10 1.25 x 10" 8.69 x 10" ~ ~ 70 0 0 2.24 x 10~ 1.06 x 10 1.00 x 10' 8.14 x 10 ~ + yw 4 e e
TABLE X CRYSTAL RIVER SI'TE BOUNDARY DISTANCES Wind Direction Distance (m)to Direction
- from Plant Site Boundary +
SSW NNE 1376 SW NE 1502 ~ WSW .ENE 1361 y W E 2161 j WNW ESE 2114 O NW SE 2523 NNW SSE 2994 ~ N S 2758 NNE SSW 2381 g j NE SW 2240 5 ENE WSW 2271 O E W 2507 ESE WNW 2475 , lE NW 1628 $.0 SSE NNW 1392 y _S N 1340 Direction from which wind blows + Distance is from edge of containment to site boundary and is defined as the closest site boundary distance within the 22.5 sector. 23 em -- 4 OM
.I Y . x.. N.. -...p q Q,. &... y. a,. w.. :. g~,<,,4:w-.... e.,, e. . p -l
- e Mm.Y.4p;;L.,..."
y .X. y,* e. . 'k p. .f* %. - - - 4 ' -.~.,,'*'., M. .s%, L.,. y';... *. ... p%. ;;. %. _ u t, 4.. w; g ...;..r.,p.- e L,. 9,. \\ .a .~.,..s..~- ...<..L.,/p, s ..s. ,u.. . O.,,s ..;.s. p,. n v.- . :/ -./ .a .M.c...\\
- y..
~ a ... p;. c Y... -. f, t.;. {r;.a.,.'{....(,A .Y {, *.. ".
- f*N.,.
-~ ...'1.. s........p...............,a ,,....,..,...... u.,.. .w. ,.,....,. w;..........:..,.,.,m..~.,.y......... .~. .......2 .x. s ...,y,.; t.,. ..J.. s,.,,, c,,,s.. s .t,. m;
- . c..
a, ..., +,r.... >,.. t.,.,/.,...y,g..... ; .........v ....,2,. e. :..a. :. e. :. c,oss,Lo j, 7.,,. <,e.... r. n >g.+P.L ~s.. a....,,9. s.-.. ,.a...
- 4..
c...., e...,.. .... n. -. n? - ~.. s a. ~..,6 r... t e.. ..3.,,.-..- s t / .v e. .. ~....... u ~ ' p* -- J..?.,..... ,s . c/., V. y - ..J.f. e .i /, 1 .,.....,.e. e s.,
- e.4 e
\\,*f *L,, *;,
- ,v",
,.-% A, ' gd. ~,,a se u t u.es t a r, L e N r 52 o es. 4- \\ g .r. i.%..; y- . C., /
- ,.....d.....',.3...................
e ..........q,
- u..
I =-=J =- . j,.... J..,...
- 3.. ' !,.e-y
(*./ '..i, n. ../,. -g. s I O .,,,,/ ' 8.. v.
- . F p g,g p g g gy s.
a ga Di$rMaRCf C Aj{sL d.5- ,S. c / l,. ...........,P.L..a, T. /,,.' . /. '.. a., 'a. [ PLauT. . 4.;. ' ' 1
- ..p.
w . q (~ g \\ '. ; / - - 175.F T. METE OROL OGIC , (.* (.
- O ] \\
ne 8A' tw1'g (6 m..'s,...a. a t $ f RIC T E D oR /'* .,g,. *. '. ' t CL usion.a a r a .:;g.- ee - ....... <,. n. f. a.
- i.g
.p_.. a. s ..,. - ~. r*' g s yry ;%,.... c r
- c,.
s..,c... . ~ e .'.).. .p
- .t '
<.'y, '.. ( s. V o. O.:g,p.:.. - '. y.' p.;.,.. ..*:..,... (._.., ;g.. v. d... :. g tuL* rant r . m..,.
- aa.* ~..s G, #'e.. i. C.
. ?. * : M. . w.s..,. -..a.:&. v. u
- 1..;.c E
s*,,g (*.,; c:, ; ;%r.. ..,'5... ,t.,ne :. . s i \\ ,a {...
- . ;..,.'L..
',.s / 'le* ~ ya i ~. m. M. 4 p /..~4. O. 8 ut. r ao LiNr e ot' . ' e. %.>.:v.,. J s .~ 0 5 (:]L 6 c. .L ,.t \\ . { g, 3,.,... g.. f'f, c' A.?;. y. ?...C'F.. '. ', 4 ., * ."'; ~ ;. ~*t. 4 s j.a ! .s'. . e. f.. ..t j ~ '.,
- g ;-
=4... l ...... ). =,,.
- p.., e T'T./,,
- 2..
o
- -ne
,e.'.*. yms l. ~~.:. i 6r- > ' i..'. j 7 p. ,, n rm ecastmt ~ ,, ~. 1 -- g n. C n... ...,....L...... t '3 f D**D ]O fQ -( vJBUd.INldl c o. s.
~y ' ? f(.. / j,,,.
- t c, y,. *.;.a.
,-. 7.a.. ~ J. , lp < ' '% {,,.
- /
e,.
- p
.b...af.. h?; ('i. ~* /,, n.*_ > ~./,e ; .4 ' * *y s ~ *^ \\. I- _,,. r ....f.,,.!. - ,.%.AJ,dQ).s*(4-
- ," ".. :. u. j
- ~ '
t ce r;.;- NA '.*,. *,.{ ,2 .x k. 't * .:f-i*k,r' ,. ~.. .. g. .8 w'... .~ n .g w,. 3.. ., N. s =.,. +
- . g
.)
- ' -[.,.,
g, .b .b el. O ' ',,' I,, , s l.. f. -r t i .4,,,.
- V=*'-
- V o
. g,-. .. ; f,, g3 ' - ~ e.,. %3-C'. '*r s' t Q- / .4,. Ie'I ;,.3 ' 7 8 ,e x 1 1. s.i a I 4:. a . '. _ ]t 2.- .\\ ... i,.%.*- 1 .'~ 'M ~ 7
- )
l . ',. - N @U..N D..A.R. Y.................. ~- ~ S i D1..R..O.A. a.......,........ i /..* d c LL TOWE R,. ,. f?., - u..
- --s t
.? ~' { -.. = = n --. I I p 1 .,p, ."l 0g G l ~ + 8 .)..___...... .a t .) '.~. 1-
- i,..
j ; l4 '. '7 .u. t, e s .,,...;,... < ;. 1.,(".. J. - e 4 g...a g. -4*.2..i a d. w.r;
- t..f,,, &,'.2:
.l, 4 ;z..- 2 g '.. 3. t...y ,. f p.t, - ~p <c v s
- . y'.. ;;'ge '.,?T;,s=%..*./ ""s.~ e -
. s. ..W s,
- t.,;
(/.1.^Q'1.'.g ~a;.:Q '. i a '.. i. t ., q.,..y..* + ~ : ph'.s.. ., a .,e t I ... r a. .. t p. .;.. -.,.., >. - M+: ' ;} - u %.,r
- ..y
...~.ue. g r ~g. ,..a,..,.- .....,. pw , " s - fG,.[ t' ...,,:, > 1 ( Q, { '. ' ,$.. : 1 * ' '; 5..~.. i g/. ; y A.,' ; . b, FIGURE 1 LOCATION OF 115-FT METEOROLOGICAL y... - r,..- e ;1 -1.".- * .v TOWER AT CRYSTAL RIVER 7 * '.$'. '. 0 g:...v. n < m,,,,, .im
g. 9 I 'Il 4
- se gre u,.
- l. -
Nv e v. 5 h .f!'-.,a_,.._,,_._,. o 2 fl L l. s 'e J d-e reeRunRY Jnwray l .ve ,ga M 4 at 9 n'& f Q Y e Ap \\ T;' ) \\ i f e y y 4 .y hv / kg y a s TRIL my I WIND DIRECTION FREQUENCY ( PERCENT ) m: m u s szzzzza MEON V7' D SPEED C MI/liR) {-
w a. 1 - ? 6 N tsN k h e-g f, 'a y gn '. (Il '" * - f 6 P C .., * ~, " [. ^ l, .X ~ w ~P a MVQi w 44 br 2 '5 I ~ A e' o" e,2,,,, o m }f-u- - '#,4 P ll 2030l$2 / -r ey s s vVE I I l FIGURE 2 CRYSTAL RIVER 33+T MONTHLY WIND ROSES WITH ASSOCI ATED MEAN WIND ~ SPEEDS (JANUARY 1,1975 - JUNE 30,1975)- ,i-f ~- I ^ i 4 .i_-_
9-k 4 .y N Ag. I 46 9 1 [ a h }R 5 8 a --r w____m a-
- ,7 yg _,...._
/ MT ( ~ gr y 4 w + i p e . j.+ JANUARY FEB R'JARY 4e sa .v.,. V. x-7,Iw
- '.. 4 7
7' ,g yA,....._ 61 + \\ 1 1 3-s j, APRIL MAY acuns VIND DIRECTION FREQUENCY ( PERCENT ) MEAN VIND SPEED (MI/HR1 om m' \\ l 4-- oa v
- m l
- 4
_y 0 / f p a.mm,y; W-1 s.,4_ 4 4% Q 4' ( .)I e p .oca u ,h-YJBCH jr-N- m k g@ m' i o w, w J. op6 s e w,- __a ( ~ /g 1' ? -I v m '1 ' FIGURE 3 ' CRYSTAL RIVER 17FrFT MONTHLY WIND ROSES WITH ASSOCIATED ME AN WIND SPEEDS (JANUARY 1,1975 - JUNE 30,1975) b 1 4
P yt 7 '~ % 4. tr 4 %g, 4 4 3 s' .+
- y
'I _ m 1 w ._ /C 4,N j r, JGPOfWf Fi RiiURRY % 4e .y !7-N v. .84 q ./ g p 4. I ru f g ::T ~- e
- J GPRTL
.'*AY n=r:: WINO DIRECTION FREQUENCY ( PERCENT ) rzrriza MEAN VIND SPEED C MI/iiR) l
.=- ~ 'v L .. wW k~ l k. s g 'g it I gg -K q pg _ Wa u m.' I 5. f, ~.3 j L. r s MIT.CH 1a 4 eg-19 ,,4-- b i 3 1 40 s JJNE / 1 i 1IGURE 4 : MONTHLY WIND ROSES WITH ASSOCIATED ME AN WIND SPEEDS FOR TAMPA, Ft.ORID A (JANUARY 1,1975 -JUNE 30,1975)-
33 FT 175 FT N N kr f ./ /~ / n [ 4/ / \\c r \\ \\ h5*r**\\'\\ f i / l / N h 5 / S, yst S, ssL S S TAMPA N4g f j, 7 '; ; $ P g,, o e= ,[ '"$R ' / s, s 5 ~
==u. re. o = FIGURE 5 CRYSTAL RIVER 33 FT AND 175-FT LEVEL AND TAMPA SIX-MONTH WIND ROSES WITH ASSOCIATED MEAN WIND SPEEDS (JANUARY 1,1975 -JUNE 30,1975)
p. m-w.n -. o ..n ~.- i i l ) r i I l h a 0 9 e O APPENDICES j 4 4 r I i i s n 2-E e t-T Y-
.m w e.. ~ t >;r-- w w>.a..,pr w myenm w y =,n,,. w m.- - m r~.-n, vr 9? o c *~ o
- ,s 3,
, s., p -, .r s, ;. p. ^ s. ~r . m r -r 9 ',,K,?..r;m
- e..
2-
- , ~ n...., -
+3 t e . : w .w. w, }.,, yy + r . Jif ;+y S,_,~+ + s , ;.
- g et
~, .u ,g
- f.
? y* v O ,. 5.. r
- s.w.h
- n ,,c. -u,,, ,#, Q 1 y,. ,, e"g >m x ~. s ~ .? '* > \\ 3,.x ':s,, ,j3 .. y ,v. q. '},. .y; ; x,,/..'%,.. ,4 7*h.+ s_ +3 a .s e., n.+, ~,_ ., c3.... 3- ~ ...,n ..n,.. ~.. n y 5 .s _ zy n - g ~ n r 4 ., g
- y.~
s..,.. ' tb '( l , %.s .o. ~.., .e ,n. . p .f s 3 '.8 o. ,=;.~.. 2' ; %.g;g : p.' %n.. u. +,
- n. c 4
,y g< e w 7 y. &,m ; p%.n;w, %.y. + - n J. w f W W; 4 p.W L.;;a .q ;.. m n,a.. ..m a %. hg? M 3.m zd6 a.7&..+q p s}py$iyV MQ.5m. n w?& j f~.f.'n ; g.$~*k W c1? m& { lp.y(.R' %,. n. w&g & g h-y,;4 yhy.gj QJ %,99 5 Q m.6p.%:9.gflhQ i-v. . h J, f; Q@l g n % % a$ p& '? J en. Q Y;pi%>,r:MP W n dygd $d 4 WM s ,e,fc,4Q w.+p$dW@p%u g ,,1 . h. n u M. y $ h W h IY.'h rW.& c.m w %g &. M m n p$y;$q h Nh h,*p v. m g.g mwnp .k,3y'M,Qy $h.4.!h,$$Y$.u$N.i.k&w hR& E WWWk,~p.g, rpg &,a. i Q.n: n n w.. m+t w % %.r.n,.4 y 2 g ;n.e M. c 0 9 r %. + Q.% ^ m e..,,o.l w%gO M.k rA~y4 y,A, u h... w.o..., , g.a+ e 4. u <,.m, 3,~ e.y.,m.,,.m i+r,. L n-w4 e .f. c s. w +a.. w+. m.,g. g m. cf y. 1 ,,, e..p m. -w a .4.,. aw. .p. a,, y e.,4;y 7 ;s nln.9,z,p.., ;p.&.,&g.av.,.. ;,9.gsq g.y.g gdm., ;.. .m.- m u ~ w,
- q,mq; 2.gA.
aqy r a n,g p m 1 ., n, s_ n. 4v.s.. y +. g-z w; a< :., ; p. y 7..w,;g.. g 4.--
- i. m..,..
w. e.
- g.,,
- $p$$, 897.a ym&wgg:.q&wm?g&s.m&g&%s hi.h.. -A -
p..% f m ,. v, .g. p. p w- %f SQ'ksWdN di. g -Np y-d g Q_*i af& vg%g;& :sl G.- l in. %.g.n W % @; % f:g.. p - Qp s g. w&x v.rESD1 g ;ggk.%g:.,::p1@.';%c%z % q.d k M P:McMq %s ;yM. 9..,U,!bfAd,M rMentMr and'.S W, J, Ma GMq4W/?hn n: 35.9 n%pmmpm&. / .g w w,w W. 4 m m. v fWG. .M.fM3 ~ $ Distrin.itMhElo.fJ3%-fdWisdTSpee4 f w V;d M M M U. m,; M S. s.%c.r.M.w.MM. 4 ~;>t. f Directi.m .m ~ w.o'Combin.m%e %;1 b m rt ~v?.g w-n.c m 4":c i i +. 2 .p.~j
- W 1.
ed ss . +.tabilityWMv
- u..;.s. /. n-for Each:andClasses Based'on,AT *,75 ft-3pL s
.3 gy w 17 a o ~ n .v. m >q. ...: e% vWm .. ~ =~.. MGW N 44 ,u s - 1 e pn qy,- 1 e s, .n. - L !'a:L. x &, m hx,.,, s ; x. % n:n a. w, 'i # Q9
- s >.
y NEMM+pg@4,y 7 ~,, -. n , u(. 7. q. ?. a m.s,. s h-g . u. m he 4 g n.? ,., n c.;+ a . H Q L,y % 3 h$gafpun;,'.;p;64N d d h $ i b 4 k @ M h @f h;& n % + 1 : 3 mmh h. NM khhY a.h.p:E52h4M N e - y a m p y g M g m. q @,.s.n. w ;, M M, p[ ! ydk8d[ T D [ , g.g g m p'h.51 .n# w%p~pGM B;wk Mk *MNC^
- h L s h. M w :
~ %gbyw. .H sa ~ Nh%g., u4..%g%y. um, e _ .3 e .. y +f a. m L 5; }# yp t. P W L I h%}jfW W is &,L y I 1 f, % +v ,'t.Q.,, Mf f a. . AG, u x hs&%&V hf. l 4[., f
- m. 3,kl fl
+ g.e ;t w n...< 3.. 9 .ge,, ; - y.+,3 m : 4.4 mm e t,, .g .. :. m u, ,n ~. ~ .,H
- h 7 '" *
- .i*
I~ N* s y n om .m y c O bu ,\\ w.e .. 3,&,',.e m. G u., , p. 8 .n. ..y4 ' L,x., .es . u. n. .m,y a a 1 i u... g 4 -'.u 3.. q-. s 7e y q <, 7 e- ' V, 9, -. 3; m g;q . y e P,, m m n-o,*,g,$,. ~ y i m m.n.. cm s.+.. mm, y:py-M.;. n. .w i.wsw x; m.m::n - o" g % w D M< m % g m ~ u J q,M Q.a m ;$: y< q .. :,y ~ - mam m. u ,w 1.k, O ls . *5f m,n, a >a ;,&.+n.,&.,p*.,n.s ,/ l . h,.+:)?f *" ? W &^. Qff '.n Q. m. m"S n u.,.x y. k y.,,Q y .->? ? M. ? "a s r ~ s$y+Y+w' k, $9mg4y, +.. a. s i m 2$;$n $ym,ag,.n$w.3[;.. N %. W.v.M$mn @ a,. $m@a D 1 -r w. ..g 9 ~ 1 ~ g 4 w dwe - n ___f M
- m
. n.v. a w.4,..,e.c Lw, a =. n-
- r..
.w + w "" +9D WMdMMWA'Mw'SCA.. _ - ~
() ' , NUS WItt3 CIFFUSION FRO $ TAN' (XI!!DVAIE) . 1 I rec - SRv:Tet aIVEe 33 FT-WintS (DEL T) ' C). .o'. SE AS3h IbCEt ! = Mt..$, A F 9, FA V _ () SEA 00N ItaEt ?= JUM,JLL, AU G , y) - Sa' AS3h Ilif 51 3s SCPe0CT,SP'T SE ASON AMCIX G = CI C, J A*', rE 8 WIND SPECC GtCUP DE SCRIPTI CN -(3-G 10 9'. WI h0 S~iSD SA >GE (P.DH) (). 1-LE SS TH AN 3. 5 2 C. st - 3.5 () '3
- 3. 51-T.5 4
7.51-12.5 5 17.51-15.5 6 18.51-24.0 q) 7' >24.0 O WIND SPEED GRCUP EQUIVALENTS () (b3 'l l C &Lt* 1-3 4-7 8-12 13-13 18-24 GT 24 d'4' LT 1.5 G.5-3.5 3.6-7 5 7 6-12 5 12.(-13.5 18 6-24.9 GT 24.0 t's LT 3.2 0 2-1.5
- 1. 6 - 3. 3 3.4-5.6 5.7-6.3 8.4 *0.9 GT 11.0
() KTS LT ?.4 c.4-3.0 3.1 - 6. 5 6.6-10.8 10 9-16.1 16. ". - 21. 3 GT 21.4 r, TE FCIR ATU.12 L A99E D ATE STABILITY CL AS SI FIC AT ICH I30EX RANGE D ...............ESCRIPTION . rs i LT-18.4 EXTREtELT uhs T AB L E a 2 ?- 11. ' Utis T A CL E 3 ? -0.1-SLICHIL Y UNST ABLE 4 2-32 MEUTeAL -) 5 2'-2.7 SLIGHTLY ST ABLE ( 6 2 4.2 97ADLF 7 2 22.3 EXTREMELY STABLE O S O C) C) C) e s. v m -. - ~+
J3 24 HOUR SUWARY nr WIN'1 SPEED OISTPIrtuTI0t3 15 .s o .j, ' F P:: -. C AY ST AL RI VER J3 FT WIND 1 (DEL T) JAN 1975 ..,O'- TOT AL NUF3EP OF RE ADIrir.S 7.42000E* 2
- O, TCTAL NU:41ER '0F dE1CINGS WITHOUT CALES ' 7 420 00E+02 O
O r.. WIkD SPEED DISTRIBUTION, NO OF 00S. LT.5 .50-3.5 't. 51 -7. 5 T. 51 -12. 5 12.51-18.5 18. 51-21. C GT 24.0 3 56 270 294 98 24 0 O O O. SUMMED OVER ALL DIRECTIONS WIND SPELO DIST1IB 1 TION VERSUS T EMP. LAPSE P. ATE STABILITY CL A SS (NO CF CBS.) O A n. c 0 E F G 1 C C 0 0 C D C 2 C D C 5 18 15 18 0 3 23 i 15 69 7J 51 41 4 55 4 15 12C 79 14 7 5 24 G 3 37 34 3 C O 6 6 1 1 16 0 8 8 7 0 C f, 0 0 0 C 4 C O O O 4 O O C 1 0 ~_ 1
W.. 3.'
- [ ()L
.FFC'- CtYSTAL IIVED 33 FT WINDS (DEL T) JAN 1975 16 (9 : OJ SUNPED OVER ALL T END.' L AFSE F ATE ST49Ii ! TIES
- ()
yx' WI AD SPEE0 vcqSUS DIRECTION (IN AUM82R CF CB S. ) f f
- f -()
~ -WIND WIhD SPEED (M PH) AT it MITER Liv 2L ,g. DIEECTICH 1-1 4-7 8 13-18 19-24 324 TCTAL f.N E - 7 .13 21 0 0 0. 38 i - () - t'! 6 28' 65 10 C C' 139 ENE 5- '38 41 9 d C 92 'E 11 3A 11 0 L 0 6C ,'()' ESE 4 16 11 0 0 0 31 e SE 3 17' 16 4 0 3 40 1-SSE G -t il 16 1 J 34 ' l,g) - S 1 14 27 33 7 0 A7 g ;,g SSW ~ 3 13 17 5 4 6 19 t' SW 2 13 7 2 0 0 24 l. () hSW 1 15 6 2 3 C 24
- s 1
14 . 7 2 s 0 .26 il kN W 2 15 15 6 2 0 47 l grj NW D 10 10 6 10 0 26 .6-f4N W 4 11 12 1 0 0 26 N 6 15 ZG 2 0 0 43 -- r, TOTAL C6 27c 294 96 24 0 742 a PE.tICOS OF CALM (NO. OF HCURS) 0 ) MISSItG DATA (NO. OF HOURS) 2 O e 4
- C)
I: f()
- C)
- c) 1 4
k ()
- h. C)
O C)
[Q' ~ FPO - CT:YSTA L. EIVFR 33 FT WIPOS (DEL T) JAN 1975 17. i.' . T E M ?. LA PST SATE STAnILITY CLASS A O.. WIk0 SPEED VEltSUS DIr.ECTI3h (IN P4UF8Et CF CSS.) WIND wit.D SPEED (HM). AT 10 HETER LEVEL DIPICTION. 1-3 4-1 5-12 13-13 19-24 >24 TCTAL ~ A'J E O O 4 0 0. O 4 f.E 3-2 1; 3 C C 15 ,rg . EP.E 'C C 7 6 3 u 13 E C '3 6 0 3 0 6 ESE -3 1 0 0 0 0 1 .g' - TE. 0 0 0 0 J 0 0 S.if a 1 2 3 0 0. 6 S G '1 3 7 2 C 13 g S3W O' 0 2 1 1 C 4 fM 0 0 0 0 0 0 0. e*e* I:SW G T C 0 0 C. 7 C 6 8 8 O' wnW c 3 it 1-0 0-14 kW J 1 3 3 3 0 10 0-1 1 3 3 8 2 H a G 3 0 C 0 3 TOTst 0 23 55 24 6' C 108 O PERICCS OF CAlti (P:0. OF HOUoS) 0 eseeeeee oseeeeeeee ...................e .g T E l' P. LAPSE CATE STADILITY CL ASS 9 wit!D SPEED VERSUS DIRECTIOh (IN t4 UMBER OF CBS.) O W:na wIi: SPEEo (nPs) AT 10 METER LEVEL DIRECTION 1-1 4-T 8-12 13-16 19-24 >24 TCTAL ANE O 0 0 0 0 0 0 g f.E 3 C C D 0 0 0 ENE C C 1 0 3 0 1 E 3 C 1' O O O 1 .O-ESE. 0 0 0 0 ~0 0 0 SE O 3 C 0 J C 0 SSC C i 1 0 0 0 2 O S c e o o a 0 t SSN 0 3 L 3 1 0 1 SM 0 0 0 0 0 C 0 g kSW C 1 0 0 0 i W 3 s r a 3 e e WNW 0 C C C 0 C 0 O W D G C D 0 0 0 t?!W 3 0 C-0 0 0 C N O O C 0 0 0 C Q TOTAL 3 1 4 0 1 0 6 r3 PERICOS OC CALM (NO. O F HOURS) 0 O s.J
o. y F AC - CRYST AL f!IVT2 33 FT WItDS inEL T) JAN 19 75 13 ~t TF 71P. LA P!E FATF STAtiI'LITY CLASS C g: WIAD SPEED VERSUS DIEECTION (IN HuPEER CF 035. )
- INO WIhD SPEED (MPH) AT 10 METER LEVEL O
DIGECTICN .1-T* 4-7 3-12 13-id 19-24 >24 TOTAL - f.*:E O C C J 3 0 AE ~; 1 2-1 3 0 4 ,o EME-6 1 1 0 0 C. 2 'r E 9 1-1 2 3 0 2 i ESE a G 1 0 Q 3 1 0; SE e 1 o l0 1 sSE-2 2 1 C C s S 3 0 0 .1 C 0 1 y ES" 3 1 3 8 8-l' O EE-3 i G D 0 C 1 kSk 9' 1 1 0 0 C 2 k 0 2 1 0 0 0 3 .g i gnw .U 2 1 0 0 0 3 NW D 1 1 C i 0 3 i 2 3 3 0 0 C O' A 3 1 1 C C 0 2 I TOTAL 0 15 15 3 1 0 34 . O
- j; _
PERICDS OF CALH t tJ0. OF h0CRS) - 0 i O O TEMP. LA PSE PATE STADILITY CL ASS 0 WIhD SPEED VCRSUS DIRECTIch (IN t!UEFER OF CBS.) .g i 3 WI'49 WI ND S PE ED. if t P F ) AT 10 METER LEVEL DIGECTION 1-3 4-7 8-12 13-18 19-24 >24 TCTAL ,i h*4 E 1 1 9 0 0 0 11 O "E S 6 35 6 C "i ENE 6 2: 3 0 J 29 E c 6 0 C u 0 6 O ESE 1 4 1 0 0 0 6 SE O 7 5 2 C 0 14 SSE D 1 4 2 1 3 P. '. Q S 0 1 3 9 3 C in SSW 1 2 8 2 2 0 15 SW 2 11 5 -0 0 0 18 O "3" 8 7 3 0 22 W-C 3 2 2 0 0 7 t o -WNW 3 3 4 5 2 0 14 O kW o s 4 3 6 0 1s 4 N'!W D 2 ~ 7 1 0 0 6 2l N 4 f1 2 i C 17 g TOTAL 5 69 12C 37 16 0 247 i O PERIO3S OF CALM (NO. OF HOURS) 0 it:: ? O O
P IFPC - CtYSTAL RIVEP 33,FT WItOS (DFL T) JAN 1975 19' TEPP, ' LA PSE 8' ATE I' A3IL'I T Y CL ASS E 'g wit.0 SPEED VF kSUS DIRECTIch (Ira iluPCER OF C3S.) NINC SPEED (f* P H 3 AT 10 METER L EVEL ' wit:3 eO DIaCCTIOu-1-3 . t-i 8-12 13-18 19 >24 TCTAL f.N E O 1 4-0 ~, 0 5 it 2 4 -11 0 0 C 17 '.g It'E 1 6-6- 2 0 J 13 E 5' 8 2 G 0 3 15 ESE 1 4 8 0 0 0 13 g~ SE O 5 1C, 2 0 3-17 SSE . 0' 1 2 10 C 0 13 -S 1 11 21 '16 0 0 69 g 33W 3 1 2 2 L '3 5 1 7 4 2 C 0 14- $4-bSW i C 0 2' s C 3 'd ' 1 3 C D G 2 4 g kNW 2 7 0 0 2 0 9
- f. k 0
3 2 0 0 0 5 g t2!W 1 6 4 0 0 0 11 t 2 3 3 C G C 8 TCTAL 18 - FC 79 34 3' 3 211' O DERICDS OF CALM tre. OF HOURS) - C O T E '4 P. LAPSE cATE STASILITY CLASS F WIh3 SPEED VERSUS DIRECTION (IN NUMBER OF 03S.) .O WI'80 WIso SerEn (nen) AT to nETER LEVEL DI1ECTION 1-1 4-7 8-12 13-18 19-24 >2 4 TOTAL Ar1E 2 6 i C 0 0 9 O xE 2 9 7 0 0 o 18 ENE 1 11 4 0 0 0 16 'E 3 12 C C 0 0 15 ,3 ESE 1 3 1 0 0 3 5 OE 1 3 C C 3 G 4 SSE G 0 C 0 3 0 C g S 0 1 0 C J 0 1 SSW 1 3 C C 0 3 1 !W C S C 0 0 C C
- SW C
C 0 C C 3 k C 9 0 0 0 0 0 kNP O O C D C 0 C NW 0 G C 0 0 3-t tNW 1 2 6 0 0 J 3 h 3 4 1-0 0 0 8 g TOTAL 15 51 14 0 0 0 BC
- s..
P EttIO DS CF C A L P. (NO. OF HCC15) 0 J LP .e b ,,...e = =,......... .=%. . - -..........+.+. ,e=-
3 + I e9 e 4 - n I. t l f l F a i D e e 9 0 ,,3 t C > @ an e,r, L,e th.t u u a
- O Ca ce t - ONO@
- 4 4
e 9 Grl .F 3-NA GD 8 9 O e f 3 s3 0.1 O O %9 U Q U m O O i. O. t . Q OgP.- .a M N f E .J 9 O3 anJ @ e M 12 > +4 O q,3 J < J c *.s = 3 ta 3 e as rs *.l3 o o u 3 l s. U z.. - t a .J - a N >=4. . tu lA >= c L MQ W e4 94 - .J H ED n h = ., -,.r.u .u,.u. .,ua uw. aaaaaa ( o 4 -s l m~C .e > a.n ...o. >= M a <> .N ' ns. 's 41 Ja .4 I e O o-e
- _t
- y. g op M m et ce u et O w eJ Q p t a u u O s N n--e e. S.S. o.
i M aJ kJ . x .a .s. m um : m t ss .> r N a i oo o. o ~ >W .sf J N ui f,e # e4 tt ce a e t a et u d.a o P3,e z [ . F8% ' M M og e.g - 4' f"1 3 2 la. g I cc - O l e i; '8 I .u. =J A. et.7 W to Pt,e N r.e u a i es *:p t.: o rt N et.am ~M ..a. - [ a . 4 r ,u fw - .o .b 2
- 4-
- O e l ..J. o -U. O> - w 2 .x x ..2 ~ . eg o l. n. v u... iu... w w m - n n n :< m - = :r z o .u.. e u t a a.. w i.... v, - woomm 2xx4z H .A. o. .I t P a . I ? O: ' O..-10 0*'O O-0: 0 'O ' O O*O O' O l0. O O- -O 'O 1. m_.- b
I, -_ gv. . i.. 24_ HOU*4 SUMMA lY C FIND SSEE9 nISTRI'*UT30th 16 + 3 FPC - CP.YST AL ?.IVER 33 FT WINOS (DEL T3 fen 1975 O" TCTAL fluSf3ER CF RkADIf3GS 6.1*.G 0 0 E + C2 g TOT AL' NUM32R OF 4E?.CINGS WITHOUT CALMS 6 18;OCE+22 s ~.V WIPO SPFED DISTRIBUTICN, NO OF CBS. O LT.5 .53-3.5 3.51-7.5 751-125 12.51-18.5 18.51-24.G GT 24.0 0-53 236 22C 97 12 0- ...y w v O SUMMED OVER ALL DIRECTIchs WI;i3 SPEE9 DISTRIBUTION VE ESUS TEMP. LAPSE RATE STABILITY CLASS (NO OF CDS.) A B C D E F G
- y 1
C C C D 0 C C + .2 '0-1 1 7 6 21 17 es 3 24 7 16 52 59 46 32 4 E2 2 8 73 E4 7 4 5 30 3 4 45 15 0 0 3 6 1 0 1' 8 2 0 0 7 C C G 0 0 0 0 ~ O .e O ~ O-O i a 3 t ,.s
y..., 'h FPC '- C'tySTAL QIVE* 33 F T t:ItDS (Of L T) FEB 1975 17: S; pl Q. J; SUM't!D OVER ALL TEPP. L APSi, A' ATE ST ACILITIES wit.0 SPEED VERSUS DIRCCTIOP. (Iti 14UM3ER CF 035.1 kI.NC FIl0 SPEED (MPH) AT 10 HETER LEVEL DIRECTI0ti 2-3' 4-7 8-12 13-18 19-24 >24 TCTAL N::E S 14 11 0 0 10 3. EE 8 14 21 2 0 3 45 E?!E f 2 ', 21 7 0 0 58 E 10 19 5 0 0 0 34' 3 tSE .2 16 8 1 0 G 27 SE 1 12 .16 0 3. G 29 ISE C 9 5 C C 0 14 3' S D 13 23 18 G G 54 SSW 1 14 24 34-2' C 75 3L SW 3 6 11 14 0 C 74 hSH 1 12 4 2 'C 0 19 N 1 33 20 2 1 0 57 E':W 2 16 28 4 J 0 SC 3 NW 6 is 14 10 8 C 48 kNW 5 6 3 3 1 G 18 k 3 17 6 0 0 0 26 3 TOTAL 53 236 22G 97 12 G 618 3 PERIODS OF CALH (NO. O F HOURS) - C HISSIt;G DATA.tNO. OF HOURS) 54 ) ) 3 .J 3 e O U .J i ,) -~_
.d a e e-ce f 9 l l l i { e e I e t 4 e J .J
- (
4 i e O O > f* u M trl J J e4 to s. e M N L. tr. ** et N e o N N cm o ce s, ce e4 we N,, a s,4 et cJ em v4 NN et et we, 9s l e e M 4 M 4 5 N t$ N A aJ u o rz o es u o es o u o i;s ei o es 7 O A o o u rs o o o o o o u u ri o cs sa o b e e et T e er fr
- se a
e w a as N e os N y K J s e
- C
.J e M:J tu 05 e M ;) anJ CP M 3*
- so we.3 69 cs v3 rJ m o es 94 a.3 J c ra rp u es.4 e
MZ >.4 o cs e J <3 o rs e,p J o cJ <1 e2 rJ o o o o e g as e at saa e .s at 8 e J2 .J l fJ M e UM w rr e w Cr th
- b. -
e aJ e tae.J I tw > 4 e-so e e-2 e) P MQ td,4 e >4 o to we /. e4 .J H E B e .J H EO M e-M e M >= n E3 c' O es.4 act t.a cs cs ce u a e N N N ee a N o u u o e to o co - e M e - <W ue,e o na u es o es sa c, we we ce o o o,e o M tJ < ees - 6 >= A e p-.C MM e v, 8 4 a a O >= O >= g M-b. at e W at e >M e 6-M .J at ;.3 aN- -e at lJ a N,e kJ QC e,) I es u o tg M I u O O. 1 e fd CL 1 w ts> L4J E es 68 r*, N J M J ** ee a,1 et J *D m 4 -9 N laJ E4J
- 3. a a u es D 'J J u u u rJ ee o e 3 c2 O u N I
M> w .44 to e M> ~ . M k I .e tL Q-et C. . Q -I e at O O I e. .,s se. us. e .J W t wJ W H .e4
- 0..
M e e O. CL M a o w tu a 2 4 (* >= r. M 4' e nM M T N
- )
e r N D k S.10 0 E O e UO O8 O s
== 4 4 4 ti M we,e u ce ci ca u ra,e F. N o u ca 2 I e >= 4. 4 4 o N ce o u o cs og u o,4 4 *2 4 o o N I T 99 mt M ,e N e H w M' M 4-6 e 2 2 La. O LC O ts e o e Ja O g H .C 2 4' l O' ra w n w - t .J e r5 rs es e-o es o en cm e. eJ.s o o es e.e r3 o 8 ) M - 3* e4 o ra ci t u,e es e o es o o u ei o o,e 2: .J J l e-i = r M O. u ( f*
- to A
O. O. O 8 2 8 o' M O .M >4 ..J G H .J O W C1 D, .et. ' .O. a- .: ow w OW O.e .a,.. w 2 := x -.a.. u - 2 x - 2 2: w w w 2 2
- u. -
se i.a..e :: 4 M - :. M 2 O re awe M #e, o M2M
- = n O
c.: 4 % Z 4>tbies:MenMbak 4 4 ;g 2 M 2 e p#
- s#g 4 -4 su tas taJ M M M to M.'s I X M.* % >=
Lu
- e a.
a. O O e I Q O.. O :: O'. ' O .O~ O OllO. O O O O O O O O.O-0 0 0-O: e
' FFC - 4:RYSTAL A!v:"F 33 FT WIPOS (DEL T) FED 1975 19' TEM 2 LA?Sr Fair !TARILITY CL ASS C ry ' WI!4G SPEdD vt RSUS DIetiCTION _ tih NUMRZ9 CF 095.) 'd! P;*) WIP3 SPEED trPH) AT 10 METER LEVEL er DI?ICTION 1-3 4-7 8-12 13-18 19-24' J C >24 TcTAL ' *i E C C C 0 J r ~. O G 1 0 C' 1 0-Er:E 1 1 0-1 0 3 3 E-0 1 C C 3 0
- 1-ESE G
1 C O w G 1 _.3 .SE D L G C U C. SSE 3 0 2 '0-C 3-2 5 'O .1 1 L C 0 2 es SSW G 3 1 1 C C 5 SW G 1 't C i 1 -t -vsu 3-4 C C 0 C L W D 3 0 3-0 0 .3 kt:W D 0 1 0 C 0 1 PN O 1 C 2 i G' 4 _w NxW 0 D' 't 0 0 0 0 ?. 0 1,. 1 C C D 2 TOTAL i 16 8 4 1 3 30 O PERICOS Ce CALH (NO. OF HOURS) - C 3-T F M A. LA PSE F ATE STADILITY CL ASS 0 3 WIFD SPEED VERSUS DIRECTION (IN t4 UMBER OF CBS. ) WIr:0 HIND SPEED (PP F) AT 10 METER LEVEL ') DI.4ECTION 1-3 A-7 8-12 13-1F 19-24 >24 TCTAL ME O 2 0 0 0 0 2 3 hE 1 1 7 2 0 0 11 !NE 1 1 11 6 c 18 E O 2 C C a a 2 m ESE C 2 i C 0 0 3 SE C 0 2 0 0 0 2 SSE G 2 2 C 0 2 4 S C 5 10 4-0 0 19 S*; W C 8 12 14 1 C 35 Si; 2 5 7 5 0 0 19 3 ESW 0 4 1 1 0 0' 6 h 1 12 5 2 0 C 2C 'at!w 0 4 6 1 0 0 11 O MI 3 1 5 8 6 0 23 01H 3 1 2 2 1 0 6 t: 0 2 2 C G 0 4 .g TOTAL 7 52 73 45 8 3 185 g PERICOS CF CALM (No. OF HOURS) - 0 O
s-1 f, FPC - C1YSTAL 4IVES 33 FT wit 0S (CEL Tl FED 1915 20 TEMP. LAFSE ' EATE ST ABILITY CL ASS .E WIhD SPEED VERStr3 DIREC TIC A (in NUMBE4 0F C3 S.) < -c. , v WI?;D fit.0 SPEED (M DH) AT 1C NETER LEVEL e 'O c: ICTIon 1-3 4-r a-12 13-ia 19-24 >24 TCTAL f.4 E - C C 6 0 3 0 6 'hE ~3 3 P' 5 11 - 'O EE ' 8 ~3 3 J 0 6 'E 1. 1 1 0 3 6 1 ESE-0 6 4 0 0 0 1C OL SE 'O 6 1C D 3 16 SSE 'O 5 C 0 0 0 5 ,5 G 6-11 7 0 C 24 'SSb 3 3 6 6 0 3 15 ,g SM-1 1 2 1 C J S ESW' 1-2 W 5 4 1 0 0 9 4 1 0 1 0 E '3 kNW 13 5 1 0 0-16 kW i 5 4 0 1 0 11 2 2 8 8' 8 8 ,0 N 2 2 0 G G TOTAL '6 59 64 15 2 0 14E 0-PERIODS OF CALM (No. OF HOURS) - C O-g- TEMD. LAPSE R ATE STABILITY CL ASS F WIND SPEE9 VE RSuS DIFF.CTIO k ( I?1 NUMBER CF CDS.) O wit:0 WIk0 SPEED (MPH) AT 10 HETER LEVEL DI?iCTION 1-3 4-7 8-12 13-18 19-24 >24 TCTAL M4E 1 5 5 0 0 0 11 0 I 3 2 D G ENE 1 8 2 0 0 0 11 E 6 7 L 0 C 0 13 ESE C 5 C 0 d 0 5 SE O 6 J 0 0 6 SSE 0 2 0 0 J G 2 O S 0 0 0 0 0 0 C SSW 1 G T-0 C D 1 SW L 0 L 0 0 eg bSW C t C D f. c 0 h 0 0 0 0 0 0 0 W!W 2 0 0 C 0 0 F + tr.4 1 2 C C 0 0 3 NNW 3 3 0 0 0 0-6 h 3 6 0 0 0 0 9 O TOTAL 21-46 7 0 s 0 74 g PERICDS CF CALM (HO. CF HOURS) 0 C . O
i; 1 2 ~ L A !T r T59sC4GCC500801E63 s1 5 3 5 4 3 2 C >0D6:0o3eC0083CG0G F C G4E 4 .5 2 H L-SU F9 S7 v10Cca300cC008G3G00 A E LN L CI ( R 5 Y E 7 Th T8 9 Ic E1 1 LI M-IT 3 B CC 010GeGCcGcr0C8DCG00 . E AE 1 F TR SI 3 D T' T E A TS . L AC l 2 E RS i1 G . C G P-( C s.
- 4 50220CeLCG0C tC0C4 3V
( s P o AD D t LE E . I E .E P' S E ) T ) S S'. R a . T t 7 U F fG D-O TA N443-72cCC:0C 0C062 H 3 T I t 3 . 3 .W W F O .2E V O I N .R .3 ( L .t44332c:CG3d831DO7 M A 1 L T A S C Y t .. C C .N O' S I' L 3 C cT A O P
- Cl E: E E
W W W' W T I t . F I: i E* SiO SWi WN O R ? i WE h? EEEsS5SSW"hKiNT E s I P C g '** g O O g l* O ..g y O.G O O O O O O O o O . 4.f';[ Q I
- 3,
.} -D, ' 24 HOUR-SdW*A Ff Or pf hD SPEFD D5ST6 PUTINtf '17 I FPC - CRYSTAL FIVER 33 FT Wit:DS (DEL Tl MAR 1975 0: -- T O T A L IJU"1 E 2, CF READINGS 5.9?; JOE +02 'g; TOT AL HUM 9IR OF; K SCINGS WITHOUT CALMS 5 92C30E+32. O-G WIhD SaEED DISTRIBUTION, N1 0F ' CS S. Q' LT.5 .50-3.5 3 51-7.5 7.51-12.S 12.51-13.5 '18.51-24.3 GT 24.0 0 24 175 -275 -103 12 0 'o O-O - . HIf13 SPEED DIST'4IBUTIch VEdiSUS T EFP. LAPSE RA TE STACILITY CLASS (NO CF C95.) SUMMZ9 OVER ALL DIRECTIOh3 A B C D E F G O 1 0 0 0 0 0 0 C 2 3 1 2 1 3 12 -3 it 4 4 38 63 32 - 19 .g-4 83 13 15 74 89 7 3 5 37 4 7 .45 10 0 3 g 6 4 C 1 5 2 0 C 7 3 C L 0 3 G 1 4 0 O O' O = ~ 0 o 'O 3 '.v n..w n ... ~... ~:
.f.j : 118. FPC - 04YSTAL RIV!r 33 FT WIhDS (DEL T1 MAR 1975 j. t !O. -O Sur.NED DVER ALL -TEMP. L APSE. R ATE STABILITIES WIwu SPEED VE F";US DIREC* IOk (IN 'JUMBER Cr 005.i~ w!?:0 WIh3 SPEED-(HPH) AT 10 METE 1 LEVEL .). DIticTION 1-1 4-7. S-1? 13-18 19-24 >2 4 TOTAL N'!E - 4 11 21 0 C J-t r, l'd ' '. 4 12 3E .3 G 3 54' ..) ' 'ENE 5 7 25' '2' 0' 0 39 .I
- C" is 3L.
-2 3 0 5! e IS~ 2 18h 14 C C G 32 SE 2 2:- 17 s C J 39 .SSE O 9 7 6 0 s. 22 e 5 0 10' 9 15 .4 3' 38 SSW. ? 3 26 34 4 0 67 V SW 3-6 25 13 i C '+ 5 2 7 i' 2-8 25 O ."S" W i 13 21 12 0 0 47 A;W 1 iL 12 8 1 8 32 3 7' '2 2 8 25 O '- trtW i 7 6 1 0 0 15 N 2. 19 14 1 0 0 36 ~ TOTA 1. 24-175' 273 103 12 0 592 Q DERICOS CF C4LM (NO. OF NOU15) - O .g MISSING DATA (NO. OF. HOURS) - 152. O' s O G. O O O o y b ..I h
j 'Q FPC - C~t YSTAL ' RIVER '.13 ' F T 'WI EDS (DEL T) ' PAR ' 19 75
- it TEMP. LAPSE l' ATE ST ADILITY CL A3S A
g: WIh9 SPEED VERSUS DIRECTION (1N !!UM C ER CF CS $ e ) WINO SPEED '(VPH) AT if HETER LEVEL. WI4C ~ 3 4-7. ; 8-12' 13-18 19-24 >24 TCTAL - g. DIMECTION, t.?!E. C~ -2 4 C L C 6 . f. E C 3 8 2 0 G 13 E:1E .c C 4 0 0 3 4 .T 'C 2 0 2 .J O 10 ESE. C G 6 C L D E. g-CE O .3 J3 0 J 3 ESE C C' 3. '3 C 0 6 S 0 0 2 5 1 0 8 -g S3W G 0 7 11 1' J 19 SW 3' 1-4 C 1 .c 6 s . h 3 H" "C 1 e C 4 9. 9 ' = r-W. D 'S- ' 16 6 C D 27 kNW D 1 5 6 1 0' 13 1.4 C C L 1 C 0 1 O t.'l W C' C' 1 0-0 0 1 A G 3 3 1 0 0 7 TOTAL 0 18 . 8c. 37 4 0 139 O PERICDS OF CALM (No. OF HOURS) - C O. g. .TEPP. LAPSE RATE STADILITY CL ASS 9 HIhD SPEED VERSUS DIPECTION -(IN NUMEIR CF. CBS.) O wit:D WIhD SPEED (mph) AT 10 HETER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 >2 4 TOTAL bHE D D 1 0 0 0 1 g AI C 1 4' O. C C 5 Erie G C C 0 J J C E C 3 1 0 0 L 1 'O EsE 1 1 C 0 0 0 1 SZ 0 0 C 0 0 C 3 S3E O O 1 1 0 0 2 S J C 1 C C 0 1 -g-SS W J 0 1 1 0 0 2 SW 0 1 1 0 0 0 2 -g '43 W 1 0 C 0 0 0 1 W D C C i 0 3 1 h.N W D J C C 6 G C Q hw e 0 C 0 0 0 0 MJW D 0 0 1 0 0' i N O 1 C 0 J 0 1 .O T TAL i 4 is 4 c c 19 g PERIODS OF C. ALM (MO. Of HOURS) - 0 C C .. ~... _
q ^ FPC -' C**.YST A L RIVER ' 33 F T WINDS mEL T3.. MAR 19 75 ZC TEMP. L1FSE F ATE 'STA 2ILITY CLASS. C g, WIhD SPEED VERSES DIRECTION ( 1 14 NUNRiR OF 09 5. ) WItJ3 '. wit:0 SPEED (MPbl AT-1'c HETER LEVEL i --O .oIsEcT:0N' 1-3 E. - ? - 4-12 13-18 19-24 >24 TCTAL t v~ t tie O G 2 0 0 3 2 NE C 1 3 1 C 0. 5
- E:f!
1-0 C 0 J C 1 3-I 3 ? 2 0 0 0 2 ESE C s: 0 0 0 0 0 g. SE-C~ C E 0- .C 0 C ,SSE. 3 0 C 1 C -0 1 S 0 0-C L G C 0-sSu-s- 1 3 c 4 SW 0 0 1 1 0 0 2 WSW i 2 2 'c 0 2 5 O-5 1 2 0 C 2 WNW C- -0 C 0 0 0 t kW C ct 1 i 1 0 3 ^O x W c 0 0 0 0 0 0 N C C 2 C G 0 2 TOTAL -2 4 15 7 1 0 29 0 PERIODS OF CALM (NO. 0F HOURS) C O- 'O TE18 LAPSF FATE STADILITY CL ASS 0 HI AO, SPELD VE RSUS DIRECTION (114 NUM3ER OF OBS.) n VIN 3-WIA3 SPEED (PPH) AT 1C HETER LEVEL DIRECTI0tt 1-3 a,- ? 8-12 13-18 19-24 >2 4 TOTAL PIE C 1 7 3 G 0 8 m PC' C 2 14 0 0 0 16 Et:E C 0 3 2 0 0 5 E 3 4 5 C C 3 9 r# ESE C 2 0 0 0 0 2 S2 0 3 8 0 C 0 11 SSE-c 2 1 0 0 0 3 S .0 1 1 7 1 0 1G SSW 3 3 6 17 3 C' 29 SW 3 1 16 11 C C 23
- g WS W -
C 1 4 O 3 5 / 4 C 3 C 5 0 0 8 olW 2 -5 5 2 3 3 12 NW G 5 0 1 1 G 7 g Nt:W 1 3 i G 0 0 5 N 3 2 3 0 0 0 5 g' TOTAL 1 3a. 74 45 -5 0 163 PEAIODS OF CALM (No. OF HOURS) - C a !ln V . - _... -..... ~ - - - - - -.... 4
7 g 'FPC - CitGTAL JIVER 33.rt WIrDS t0EL T) PAR 1975' 21 ~ TE11 LAPSC FATE STABILITY CL ASS E - O-wInn SprEo vEsSuS DIricTION (Its NUMBE4 0F.Ci3S.) 5I1:3 hING SPEED IMPF) AT iJ.t'ETER LEVEL. - O. aI4EcTION-1-1 4-7 e-22 13-1e 19-24 >24 TcTAL . t.t!E 2 4 3 0 0-0 9 f.E 3 '2'. 6 0 0 C. S ' O EVE C-1 13 0 G 14 E. 3 6 16 C Q G 2? .CSE 5 7 6 0 a 0 15 -Q' SE' O .5 5 0 0 0 10 SEE 1 3 2 1 0 3 6 S 7 5 -3 2 3 17 Q; SSW C 0 11 2 J G 13 'SW 0 3. 3 1 0 0 7 WSW 3 3 C '2 0 5 W 1 4 4 0 0 C 9 - g . W:1w 0 4 2 G 0 0 6 bw 3 1 1 1 C 0 3 . g-N:2W D 3 4 C 0 0 7.. I: 0 7 6 0 0 0 13 TOTAL 3 60 89 10 2 0 164 'O PERIOCS OF CALt' (No. OF HOURS) - O c g TEMP. LAPSE PATE STABILITY CLASS 'F WING SPEED VERSUS DIRECTION IIN NUNDER OF 03S.) O sIric WIko SPEEo tsPHi AT 10 e c'2R L EVEL DIRICTICN 1-3 4-7 8-12 1!-18 19-24 >24 TCTAL retG 0 3 7 0 0 0 5 E ' 1 i G 8 0 2 - O - It;E G 3 L 0 J 0 7 E C 3 0 0 0 0 3 ESE 2 4 0.- 0 0 0 6 g SE J 9 1 0 0 0 it SSE O 4 C G S C 4 e-S 1 1 G C 3 0 i V SSW t C G U 3 0 C .SW D 0 0 0 0 3 3 e WSW C 0 C 3 0 0 0 W D C 0 C 0 C C t.trW i e c C 0 0 1 e, NW 0 1 C. 0 0 0 1 Et H C 0 C 0 C 0 9 N. 1 3 0 ,c 3 0 4 g TOTt.L 5 32 7 0 w 0 44 O PERIDOS CF CALM (NO. OF HOURS) - t - O r3 4
1. I .L-r TN. 6 1 I 'l. . N., i- .l. l 4 h' A 1 i i-e o e ( -. 9 e .8 et>- -U
- = b', ifn a0 M N b% C
- et u O t1 O t., u,4 4 J f*b
== e-M 4 CD - N LD A es v3 C2 O aA Cs e a o o ca o o sa sa o O O -b tb tv ' Y l (3 .. N l-E. _J e-. l ' M :3. tas O' < l M3 3e e4r3 u t.3 o 1 O esesaJ Q q csc3 o es n es -.c . u - . d >2 .,,6 j i . e eg l' - m > - w-
- m. -
x
- e. e I
Cs. Wo O. to t v4 [ . 4..a a4 Y t - I eeW M c.4,.4o g* a rvcso cso osJ o csu uca ose-l N to O W.. e eeJ - L
== N
- yn.
e. O 6= .> -.; b.>= M ' er .J-at D ec uJ (g 11 -. Z 4 G 'C j O*. LL I wJ g 7, c N.3 w J u es u sa o na t.s c3 o u a u P3 t/3 g &D r
- p. g.
oJ m. s .4 -W 3 H. he tiJ - a 3 e CL CL M f-' eM M tr F Z
- =.-
D 6 _ to t f'3 ' () 9 - O
- >= 21.. af J ** N M M N M s.e w as o cm oo e3,4 M CB 3;
_M _ >< : 64 . e4 I e1 2t. ;s la Q ( .g .t3 e Je O (. - M, M.. .2 {'- e a w N M.s n., N n o.. o o a n n o - es z t .g ' be - ~ et f: M O
- p. -
I e i
- u..
'O~
- g Q
I l 4 O M te a CJ f yO-f3 >= - at a-
- v w. w w - w. 2 2c2. x.-.
.O 4-e i.- - 4, . M M n es* n - ti he o MM L-
- Jr w 4 ;c t=J hJ us &s us M us vs.t e ' n 7 ?.
O tv I ( s.g. ~ c.t ;c a: ; 4 >= ' aas. (L I O .f V i i
- n. 4. _.
. -OJ O. ~10 : ' ? O.. m .el } m r); c O :OL :. 'O. 0 O. 0: O 'O 'O 'O 0 O~ 'O O l,.i
' Q:.
- i.
24 HCUR SUtdA Y Or, uy p:9 5pCE3 'DIST?IOUTIOM '15-F'C - CPYST AL P.IVER 33 FT. WIN 05 (DEL T) APRIL 1975 ~- TOT AL L KUM3 2it CF *. CE ADINGS 5.9930~,E+C2 g, TOTAL: NUH"tIR nF REn cINGS WITHOUT-CALPS
- 5. 93 C C2 2 + C2 O-O.
WIND SPLED DISTRIBUTION, NO CF ODS. O LT.5' .50-3.5 -3.51-7.5 7.51-12.S 12.51-18.5 18.51-24.c GT 24.3 3 45 1241 322 81 8 2 O' .................................s...... g C. SU:tM20 OVER ALL DIRECTI0t.S - W nD SP EI3 DISTRIBUTION VilSUS T EP.P. L APSE P.A TE ST ABILITY CLASS (NO CF CBS.) ~~' A s c D E F G 0 1 6 6 c' O G C C 2 .C 1 C 7 18 9 10 3 17 2 5-42 1:3 53 19 '0 4 73 14 27 96 1 00 .12 E 5 14 4 6 39 17 1 3 6 6 0 C 2 C E C 7 C C C 1 i C D O y O ) 1-i3.:ck l
.w. 4 j.. Jg_ c._FPC'- CtfSTAL RIVER 33 FT WINOS (021 T) ATRIL 197C . 16 ,...i-) '.,) n
- SUMMCC OVER ALL TEMo. L APSI R ATE ' STABILITIES -
WING SPIED.VERSUS DIT;ECTIo k. (It: t3UMBE9 Cr cas.) ~' ' e - WIi 0 WIND SPE:D (NPH) AT 10 MITER LEVEL . DIFECTICH 1-3 4-T. 8-12 13-13 .19-24 >2 4 TOTAL .H Z - 1. 10 26 1 ? 0 36 3 ,NE 6 8 34. 1 0 0' 49 ENE'* 4 22 16 1 0 0 43 E 5 36 15 7 0 0 63 ESE-6 15 7 0 0 0 28
- g.'
CE-l' 16. 3 5 0 0 77 SSE .4 19. '13- -2 J 0 33 S 1 9 . 17
- 7..
5 0 34 SSW i 5 31 14 3 2 53 . S'4 2 10' 27 21 1 3 61 y kS W - 2 13 18 0 3 0 -33 'e 3 18 27 '.3 0 J 51 %?:W 1' 14 33 6 6 .0 6C m' ),u ? 8 18 8 1 0 37 NNW 4-9 11 2 0 0 76 N '2 27 28 3 0 0 60 g . TOTAL 45 241-3 22 81 .8 2 699 PERIOOS OF CALM (NO. OF H0utS).- 0 g H:SSING D ATA (N1. OF HOURS) 21 O a O O o O O o ? e 'e/ .e..... ..e..-~ a .n-
7' ~ 1 L L A A T T O O T6433C215t262920Pu TO1Ca8130731221CC1 1 i 22 i 2 .g ,) ) S 4 S 4 O 2 S 2 C >U3030o0J0GG0J030d C >O0008030000L00000 F F O 0 AR 04 E 4 E 4 B 2 B 2 M L - M L-SU E9 SU E9 SN V1CC000:0 vCJJ060006 SN V1O200803000003000G A I A l E LN L Ll L I CI E C. ( R ( R 7 E 9 Y E Y : 1 TN T8 Tt T8 IO E1 I0 E1' LI H - H. 3 L LI IT 3 I IT E DC 01990502C02I0040014 PC 010000010021C000004 a AE 1 1 AE 1 A TR TT SI SI ) D T D T T F A C A TS 1S L AU ) 2 AU ) 2 r FS H1 C RS b1 C p
- e P -
R P - 5 E M.86323Cs14824672C53 EI H800CCSO3C51i121CC4 ( SV ( 11 7 SV ( 1 S F P C. AD D AD D t LE E LE E E ) E E ) .E I D P S .P P S W
- S S
R PS S R T M 1 U M 7 U F " C C - C E D. D-O A4C112L3 2 10C262&327 H Tt N403*,CUOCJ01010CC02 H 1 I 1 I I 3 W h F W W F O O P. V O O I N t( { 1' ( 3 L 1GS2GGOO3C390CGD30 M 101DCOOCJ3GC0G03D1 N L A L A T A S C C Y R E FC C O N N .O S O S C cT ' L O I L. 3 I A O A C OT C! E E E W W W W T I P I;C' E . SWS
- W 4' O
R IEl El SES SWS ! Wt O R hc E E w W W W' T I i : F I! SES' E 'W G M: SEESSSSS 4WNNNT E t ?? E E E S S S E S F W w N i h. T. L P? t D I P I D .O D. g, g*O g 0 3 -. g 3 O O O. p' ^ O
- e."
0 g O.3 O , a. f*' k d
-q b e : . )) FPC - CRYS TA L JIvl:c. 33 FT WIr800~(nEL TI t MIL.1975 18J TCt*. LA PSF EATE ST ARILITY CL ASS C ]. wit;D SDEtn VER50s DIRECTIC A (1*# NUM81ER CF CB S. ). WI t.T) WIhD SPEED (rtPHI AT 13 METER. L EV EL DIEECTION 1-3 4-7 8-12 13-18 19-24 >24 TCTAL t.':2 ' 0 2_ 1 C 1 C 1 . t.2 0 C 1 C C 0 1
- )
5: I O O 2 0 0 0 2 .E G 1 C 1 3 3 2 ESE O 1 C 0 0 'O-1 )-
- SE D
S -C 1 1 0 1 SSE 1 C 0 3 J 1 5 0-0 '2 1 G G 3 .) 574 0 ~ C 3 2 0 0 5 . S'4 0 1 5 0 0 0 6 bS'J 3 6 3 C 0 0 1 3 W .0 C 3 0 0 0 3 %r:4 C 1. 5 1' O C 7 F4W G G 1 0 0 C 1 g ArtW C C 1 0 0 0 .i
- s C
G 0 0 C 0 0 TOTAL 0 S 27 6 6 0 38 ) PERIO3S CF CALM,(NO. OF FOURS) - C t' e s e e s s e e ee e ee e e eeee e e e e e e e s e s........... 's TEMP. LAPSE F ATE STADILITY CL ASS wit D SPEED VERSUS DIREC TI0h (Irl IJUMetR CF.03S.) WIND wit!D SPEED (tiPH AT 10 f(ETER LiVEL ) DI FECT IO N 1-3 4-7 8-12 13-18 19-24 >24 TCTAL hME O O 9 1 0 0 10 s I!i 0 1 8 0 0 0 9 Er:E -2 1 3 1 0 C 7 E C 4 9 C J J 13 iSE 1 C 2 0 0 0 3 SE O O 2 1 J 0 3
- SSE, C
5 5 1 3 0 11 ) S O 6 S 4 0 0 14 SSW 1 5 12 5 0 1 24 SW D 4 10 18 1 0 33 .) W3W .1 3 6 0 0 3 10 W 2 5 E .2 0 0 14 Wr:W G 7 8 1 4 0 16 kW G 1 0 4 1 0 12 KMW G 0 1 0 0 0 1 N C 1 5 1 0 0 7 ) . TOTAL 7 42 96 35 2 1 187 ) PEP. ICDS OF Cf.LM tt10. OF HOURSI - 0 3 1 3 -4
9 - 1 ~ t L A A r T C O T 95676 261773n6C349 T0332863100CCC0185 2 111111 11i ?223 1 11 17 -2 ) ) S 4 S 4 B 2 B 2 C >3C0GC00G1 600300C1 C >030J0G0050C000C00 F F C O ER FR E 6 ,E 4 G 2 B 2 M L-M L - SL E9 'SU E9 SN V1J30GG399003000 a03 SN V1000G0J wd000000000 A E A E LN L LN L '9 CI CI 7 ( R ( R . 9 Y E Y E 1 Th Ts TN T8 IO Ei IO E1 L LI M - LI I P ,I IT 3 IT 3 G DC C10C01081232C104217 BC C1010S000O00000D001 D AE 2 1 AE 1 A TR TR SI SI ) D T D T T F A E A TS TS L AU ) 2 AU ) 2 T FS H1 - 0 DS H1 C O - P O - R P - ( ct MeL1715 d94218920 EE t; 8312CG00000CCCC062 8 f SV ( 2 10 SV ( ,5 P 1 P 1 ' 3 AD D-AD D t L i. E LE E .E - I E ) E E ) . W A P 5 .P P S
- S S
P, PS S R T M 7 U 4 7 U f F F3 D-O EC O-O T 4 N443336s02C48 646' 13 H Tk N46i09762i30CC0O1t3 H t 1 I I 1 i1 A0 I I 1 i5 ~ 3 W. W 1 F W W F O O DE V 0 O I H H - I i ( 3 ( a ,L T
- . t211S33i122ii124J2 P
11ai31o1S DCGCO029 P A 1 L L A A S C C U F F - C C C n N o S O S I C 't L D I L O T f' A O OT A O H T I NCE E' E E H W W W T I t cE E, E E W W W: 4r F IEI E t SES sus r : O R IENEM SES SWS HI l O R 9 MXEEESSSSSaWMf NET E hDf n E E E S S S S S W W W h N. H T E i I P I P 7 c D 4 g .g O O, g g O O 0 g g O g*3 g g O.9 O 9 E} ;i; ,~
3 r - i, t_ ', O 'N' e o e 4 e eJ ' at t=- C > u C 4 @ N P7 M u 49 e o o u e4 u M @ N a e M J CO N O A o es o e o es a c.3 ra o r3 o es a o a c3 b C D's. J' re ps N. E ~.J B (#l D ' id C5 OZ- > *e(*s2 O o is ee o *)ea o e o o o r3as o 4 14# .'~.) M ' .J LA _ ' O M - -N . =,. nd. so ty' w*- we
- e. 2 p
,.J .I *4 ' ed e* Ho E8 .. M. M s=
- . 5 W ' (D O ^
FJ ee 44 o O O O O O O c3 r3 43 m o fu r3 O O Q ' *f AJ 99 at k g- -'MH O t- . t= w, og ... t= M < . '.J er D aN W- .C;. tr. V3 % ee O g ' al
- . gg L. et to o e u <J o o o as es.a O u u eJ 83 O M.
t 'O 1 - 2 '. at Cns - O-0 .A saa 8d ' sun H . e IL ' tak 2 L to > ' t1 M. _ to tv
- 3..
-N 3 6, tai C5 ' CD O
- = 4 4 4 u N 39 N ee N *4 en eJ u es O f 3 v4 o P) 05
-M N H- ,4 ' Pl, 3, J LL O .n'. td ' e C oe ' et ' -m.. 2-so ,0 ' -J 4 t o J *S N H +4 N C5 43 u t'* 'S fJ ti r1 O O E ' et e4 .J k-M - 4 O- '>W* tu O
- O
-2 g-o - gn .. H 3 n
- Q'
. g% D. -. tot.91 ' id.. y. es ~ c t\\ ' . M O tai 2 % '. 3 7 M g . in, ^ H ies :? s,t ;: M tal ta p,g g,9
- 3 *4 o
W 2 ft 4 Z 4tg kg has trl M.. M. M p.K 3 3 2 *4 4 D* 4d Q 4 .' 6. e - $A e w'.g eE
- ab et
'm se m ? '.m ' ee ein -4 sm. m. m. A aut sum '. A-'
- 4h
- M w
. - -... ~ ~. _ s. 24 HOUit SUVi A
- f Or wIh0.SFEkD DISTRIBUTION 15 ' '
.FOO C2YSTAL PIVrR 33 FT WINOS (0ZL T1 '4 AY 197 5 i TCT AL NUM"lER CF RE4 0!NGS - '7 29C HE+02 j TCTAL-NU41ER' 0F RE ADINGS WITHOUT CA L HS 17. 253 d 3 E +!!2 o O 'IO WING S*EED DIST2IGUTION,l AO OF 085. O LT'.s. .53-3.s -3.st-7.s -7.st-12.s 12.51-1a.5 is.st-24.c GT 24.e 4 70 319 333 .35 i C .O. O SUMMED OVFR ALL DIFECTI0tS WIND SPEED DIST9IPUTION VERSUS TEVP. LAPSE kATE STADILITY CLASS (NO CF 095. ) A B C D E F G g 1 3 C' O w . 3 1 2 0 0 1 8 18 29 14 3 25. 4 15 65 119 74 21 3 4 114 15 22 94 43 11 1 5 17 1 2 13 2 C C 3 6 0 1 0 0 G G O .7 0 3 C C 3 0 C 4 0 . 3 3 i O-O 3 O 4lluuPe. I
lg LFPC - CRYSTAL "4IVER 33 F T WI NO S ( D EL T) HAY ' 19 75-16'
- 0 g
SUPrIn-CVIP. ALL TEHa. L4FSE.RtTE STA9ILITIES . WINC SPIED viksts DIFECTION (IN HUMBE? CF C3 5.)
- n WIND WIM SPEED' -(N*H) AT. 15 HETER LEVEL DIGICTION 1-3 4-7 9-12 13-18 19-24
>24 TCTAL-SNI. S 8 2 0 0 0 15- .. O t.E 11 10 7 C 3 .L 78 fuE 7 29 19 0 G 3 55 E la 146 11 1 J C 76 O IS2 9 33 5 'C 8 - J M4 8 "7 SI 4 61 18 1 0 SSE 1
- 13 14 1
0 0 ?6 .g 5 0 7 11 .3 0 - 0 21 SS W 2 3 14 3 0 0-27 .54 1 8 23 13 1 0 4b O 53 " 17 38 7 3 C 62 u 1 35 73 2 G G 111 -%MW-1 -12 34 2 0 -0 49 O 1' 7 21 2 C 8 31 NMW i .10 5 0 0 0 16 N 8 18 5 t J 0 31 .O
- T rat-72 319 3ce 35 i
c 725 (y P*RIOD3 CF CALP (NO. OF HOURS).- 4 MISSING 1ATA (h0. OF h00RS) 15 ,O~ O O .Y,9 .O O O O ~
+ A,;
- QL
' FPC - C4YSTAL '8IVE'A 3 3 F T, WI t.D S (Ort Tl t*AY 1975. 17 T 2 t*, - LA PSF SATE-STABILITY L NS S O-WI r e : 3'2E ED VE3 SUS DIEECTIch.(IN NUM BE t CF CB S. ) , AT:;3 WIM' SPEED (t' P H AT 15 NETE4 L Evil
- O' DIRECTION 1-3 6-7
's-12 13-18 19-24 >2 4 TcTat t.!!E 0 1 0 0 0 0 1 ' t:2 C C C 0 0 0 i E 2E 3 1 1 J J G. 2 .Ez u 2' 4 0 3 C 6 ESE. 2 C-2 0 J' O 2 .. g - SE. O G C 0 0 D C SSE C-C 2 0' J e 2 S J 1 6 3 J C 6 'O. 5:W. e. 0 2L 3 13 SW 0 0 3 5 0 0 8- 'a 5 W C, 6 14 4 3 3 2L. W 3 1; 48-G G 58 g WitW 2 2 i<1 1 a D 2. - Mt 2 1 8 1 0 0 10 O- '8 0 8 '8-G 'O 8 N-C '1' O C 0 2 1- ' TOTAL' 3 25 114 '17 0 0 156 LO PEGIODS 0F CAlt! (NO. OF FOURS) - C O ,Q TEMP. LEPSE R ATE - STABILITY CL ASS 8 WItJC SPEED VERSUS DIRECTION (IN tiUllBER OF CBS.) n. hit!3 WINO SPEED (MPH) AT 10 NETER LEVEL DIRECTIO.i 1-J 4-7 8-12 13-18 19-24 >24 TCTAL t r:I O O 0 0 'G D 0 g NE O G 1 C a 3 1 E'3 E G 2 1 0 1 0 1 E 2 C C e D G C ESE 3 0 0 0 0 0 0 .g SE O U 1 C U 0 1 3SE O L 1 0 0 0 1 3 S 'O -0 1 C C 0 1 SSW D 1 1 0 0 3 2 Su o 0 1 0 1 C 2 O "S" 8 1 5 C C 0 6 W C J i 0 J G 1 W':W 9 2 C 0 0 0 2 O h" C 3 1 1 0 0 2 tit:W 1 0 1 C 0 0 1 t: O C 3 0 0 0 C g TOTAL 3 4 15 1 i C 21 PERIOOS OF CALM tilo. OF HOURS) - G 0-O
- l. J.
m p%' .c FPC - CtV S TAL ' 'iINEvi 31 f f WINDS ;. to rL 7 3 - PAY.19 75 18 TEMd. - LAPSE. GATE S TABILITY t;L ASS -C. g-WIEC SPEED VLP. SUS DIRECT 10h' (IN tJUF0iR CF CSS.) b It 9 ' WI P.O ' SPEED - (t* PH) A T 1C NETE t LEVIL -0 .DITECTION' 1-3 4-7 $~12 13-13. 19-2 fs >24 T C T A L'. 9.sti 1 C C C C 1 tE J C 'C C .9
- 0~
' E E 2 8 8 8~ 2 E 1 2 C i G 3 ESE. 0 1-C C C 0 1 -Q Si 0 0 C 0 s 3 C ESE J 1-0 0 C 1 S O -0 3 0 u 3 3 O ' SS61 .3 J 2 0'- 2 0 2 ' SW : C C 3 2 C' O 4 E kS LI 0 3 1 0 3 C-Q. b 3 7 4 0 0 0 11 W:W 3 2-1 0 3 C 3 f;W -J 0 3 0 3' C 3 Q-M:A C 1 C C G 6 1 1: C C G b G 0 0 TOTAL i 15 22 2 G .C 4C O'
- ERIOCS OF CALM (NO. OF HOURS)
C C O TEMP. L A PSC RATE STARILITY CLASS O WIND SPEED VEFSUS DIF.ECTION (IN nut!EER CF CBS.) g. KIN 9 WINO SPEED (PPH) AT 1C HETER LEVEL DIEECTION 1-1 4-7 6-12 13-18 19-24 >2 4 TCTAL M!E 1 2 1 0 0 0 4 O NE 0 8 3-0 C 0 3 E!iE C 1 3 C a 0 4 E 1 5 1 1 C 3 8 a 'O ISE C 2 1 0 0 0 3 SZ 2 12 13 1 3 0 28 SSE 1 3 a 1 J v 13 5 '2 2 0 3 2 6 O SSW 0 -6 1 0 2 0 7 SW 1 7 15 6 0 0 29 WSW 3 3 15 2 G 0 20 g W G 12 1 J C 19 kNH i 3 8 1 3 0 13 O ou 3 3 6 0 c 0 9 N:!W i 2 3 0 0 0 6 N O 6 2 0 C 3 8 g TOTAL 8 65 94 13 0 0 180 O PERIOoS or CAtie Nn. OF HOURS) - 0 O O
t a.. g. FPC - CtYSTAL TIVEP 33 FT WI!GS ' (')EL' TI. MAY 19 75 19 N T.*MP. LAPS! Pt.TE STI.3ILITY CL ASS E bO-
- wit
- 0 SPEtD vtsSus cIRecIroN (In wuxcE= cr CaS.)
l ' WI C . WI AD SPEED - (MPH) AT
- 10. HETER LEVEL O.
DUECT IO N 1-3 4-7 8-12 13-18 19-24 >24 TOTAL ' AME. J 3 C C e C 3 FE 4 'S 3 0 0 12 q, . E P.2 - 2 5 .5 0 0-0 12 ~ E '3 12-2 C D ESE' 2 17. 1 0 0 0 .25 ' 'Q SE 3C 4 O C S !SE. J 7 -2 G 0 0 9 S 0 2 1-0 C C 3 .,"3 SSH 1 '1 .C C. 3 2 SW 3 C 1 0 G 1 f: .h'W C 4 3 1 3-C 8 i 12 8 1 8 '8 22 -O h*:W C 3 7 J G 0 10 NW i 3 3 0 0 0 7 "'n 3 6 i s 3 7 O N 4 5 2 0 C 0 11 TOTAL 13 11 5 43 2 0 3 178 O PERICOS Cr CALM (NO. OF HOURS) C-O O TEMP. LA pSE F ATE STASILITY CL ASS F ' WIhD SPEED VERSUS DIRECTIOh (IN NUMBER OF CSS.) Wu: WIND SoEED (PPHI AT 10 METER LEVEL O DIRECTION 1-3 4-7 6-12 13-18 19-24 >2 4 TOTAL tNE 3 2 1 0 0 C 6 'I '6 5 8 D C 8 11 O SNE 3 16 7 0 0 0 26 E 9 19 1 0 3 0 29 + SSE 4 9 1 0 0 0 14 n .V SE i 15 C C 0 0 16 SSE O C 0 3 C P .g S. 0 0 0 -0 0 0 t SSW i C 0 D 0 0 i 4 SW O 1 0 0 0 0 1 w:W J c c c o 0 0 ~O-W D C 0 0 C ? WNW G 3 C 0 3 0 0 h4 0 ff C. O 3 0 0 e g' huW D 1 0 0 G 0 i N 2 6 i C 0 0 9 O TO 29 74 11 0 0 0 li" O-PERIODS OF CALM (H'). OF HOURS) - 3 O i e 0 -a
./ j. E' 15 r jy ~FPC..
- C1YSTAL 71VIt.33 FT WIVJS;(DiL Tl MAY.1975 4 23:
TCo?. L APSE, F ATI' STABIL ITY-CL AGS -G WI 20 ' SPEED Vf
- SUS DIPECTION ; (IN ' NUMBET OF CBS.) -
j--g w! *to - . WIh'D - SPEED MPHI AT ' 10 MITE 3 LEVEL' DIFECTION 1-3 .L-7 12. 13-18 19-24' >24 'TCTAL t.t!E O . 0 :' 0 .0 0 0 G -NC .1 .C- !C .C. 0 1 ..y E**E : 2 6-C C . C..' 1
- E-S' T'
.1 .0 5 C' 13 ES! 3 -4 -0 0 0 0 7-M. 'SE 1' 4 C -0 3 3 5 SSE- -3? 2. C -- C 3 C t S C.' C- -C 'C* G D- ?- iS!W ~_ S. C-0 .C 0 0. C 3-, S'4 ' .0' 0 0 0 0 C 3 .. wsw C ~ ;-
- C 0
-3 0 W 3 G' -C C 0 f4 C . 3-kNW D C 0 0 3 'C C kW ~ C 0 5 0-0 -0 0 g' EtJ W : G G C 0 G 0 .C -N-2' 0' C G 0 0-2 JTOTAL. '14 21 1 C 0 0-36 . g. PERIODS 0? CALM (NO. OF HOURS) - 1 O 3 e - O .,e. P .4 t O O O. e. U ~
.c:. 24 HOUR SUPMARY OT WIM SPCED DISTSI'luTION 15 F7d - CRYSTAL - P.IVER 3 3 FT wit:DS --(DEL -T) JUNE 1975 3 T CT AL NU:OE,t ' CF TEr.CI.NGS 7.t90000+02 'g TOT AL NUMBER OF 'tF ADIMGS WITHOUT CALPS 7.C90C3E+32 O e....................................... O WIko SPEED DISTRIBUTION, NO OF 085. O~ LT'.5 .50-3.5' 1.51-7.5 7.51-12.5 -12.51-18.5 18. 51-2 4. G GT 24.0 C 67 327 294' 20 1 0 .y. e. ve................................... v, - SO4:1ED OVER ALL DIFECTIOhS WI!J3 SPEED CIST'tI9UTION VE~tSUS TINP. L APSE RA TE STA9ILITY CLASS (NO GF OSS. ) A D. C D E F G .;j 1 C C C G 0 0 2 0 0 0 11 23 28 5 g' 3 29 2 i t.- 62 144 70 15 4 93 14 23 83 69 it 0 5 5 1 1 7 6 0 0 3 6 C C 0 0 1 0 0 7 0 G C D G 0 C .y c. C ene c ~. 2
--og l; ' q).- - 'd 61 .FPC - CR YST A L 4IV ER 33 F T WI N0 5 - ( D E L T) ' JUNE,19 75 '
- }-
.t: j 0 :- C). (). SUMMED OVEk ALL TEMP. L APSE k ATE STADILITIES WIht SPIED VIDSUS DIRECTION (IN truMBdR CF CB S. ) WIhD SPEED (MPH) AT ic HETER LEVEL () WI *aD 1-3 '_ 4-7 6-12 13-18 19-24 >2 4 ' TOTAL DIFECTION - t;NI 6 19 4 1 0 0 30 'S 18 17 1 C-J 41 ~ () _ - f;E + ENE' 5 32 25 1 0 G 53 E 1E 63 11 1 4,- 2 91 -s ESE 18 32 - it 0 0 0 60 SE -5 53-7 1 s a 63 SSE 0-12. 4 0 t s 15 f(y 5 1 5 4 1 0' O 11 ~ -SSW 1. 11 11 1 1 0 25 -SW D 9 20 1 0 0 3C WSW 1 14 21' .C 9 0 36 (-j W 2 28 92 5 u 3 127 kt;W i is SC 1 0 0 67 6 11 5 8 8 26 O '- litlW 0. 4 3 0 -0 C 7 N 2 9 4 1 C G 16 () TOTAL 67-327 294 20 1 0 709 - ()- PERIODS C CALH (HO. OF HOURS) - G HISSING D ATA (NO. OF HO UR S) - 11 O O () O f - C) C3- . () 4
.~ . )- 'Q; FPC "-', CRYSTA L _ GIVJO 13 F T WIFPS (DEL T) jut!E 1975 I17 N T E tip. LA PS~ PATE S T A91LI TY OLASS 4
- 4; g -
, WIf3C SPEED Vf PSUS DIRECTION (IN NUMBER CF CB S. ) 5 i'
- wit!D WIN') SPEED - (HoH) AT - 10 HE TER L EV EL
.. ' O: DI7ECTION 1-3 8.- 1 6-12 13-18 19-24 >24 TrTAL t'.E-0 1 0 0 0 0 1 ' l'E O .C t-C .0 C C ^ y' CIE-0 2 2 C J C h E 1 -4 C-C 3 4 8 ISE' 2 1 C C 0 0 1. ~G-SE D C 1 0 0 0 1 SSE O C C C 3 C ? S 3 L C -- 0 J C C . O SSW 0 6 2 0 0 e 2 . 5W. -O' 0 1 0 0 0 1 j WSW -C 0 1 0 0 0 1 -g W 0 4 SL 1 ~0 C 55 WP:W C .5 34 C J 3 39 (}1 f:W - 0 2- -6 4 0 0 12 g- ':" W G C 0 0 0 3 C N C 1 1 0 0 2 2 TOTAL 2 2t 96 3 0 123 -s,,y 1 ( PERIGOS.Or CALM ( t!O. OF HOURS) 0
- C g
TEMP. LA PSE I4 ATE STABILITY CL ASS D wit!D SPEED VEPSUS DIP.ECTIOk (IN NUMBER OF CSS.) i ! O WIna win:D SPEED (H PH) AT 10 METER LEVEL { DI RICT I0 t4 1-3 4-7 8-12 13-18 19-24 >24 TCTAL N'IE O 0 0 0 0 0 0 'O 'E 8 C C G J G 3 Ef f E ' 0 -2 0 3 J 2 O C 3 0 2 C 3 Est c 0 .1 0 0 0 1 'O SE D G G 0 0 0 C SSE O 0 C C 0 0 0 .O S 0 C o e 0 0 e i SSW C D 2 0 J C 2 SW D 0 0 0 0 0 0 .g W3W 0 1 3 0 C L 4 W C C 3 1
- J D
4 WilW - 3 C G 0 0 0 C , Q. kW 0 0 0 0 0 0 0 NMW 0 C 0 0 0 0 C 2 1 K C 1 0 0 0 0 1 Q TOTAL 0 2 14 1 0 0 17 - ! O PERI oS CF CALM (t;o. OF hours) - 0 i
- o
? ,1-f, Y e
P: 1 Es c O. Ff C - CayST AL 9:t'fr, 33 FT wit:DS IDEL T) JittC 1975 , ' 16 ' TC U. LA PSr rAir STAPILIrv CL CSS C g' WIlsC SPEiD V4 WSUS DIRECTIOh ( IN t:UN EER. CF.CB S. ) WI t:3. wit.C SPEED'(MPH) AT 10 MITIR LEVEL O DI cCrIcx-1-3 4-r .2-12 .13-ta 19-24 >z 4 TcTAL ANE O 1 0 0 3 G 1 ' I;2.. 2 .G c. C L r .Q' EP:E -' O 1 1 .0 0 0 E.. .G 2 3 G 0 0 5 ESE 3' O 1 0 J, C 1 O .si. s c 1 0 3 0 1. SSI' ? 1 ( 0 0 0 1 3 0 0 0 0 3 0 0 S3" S P 1 'i ~8 3 O' S4 0 1 '2 G, C 0 3 hSu a i 2 e c. G 3 k-0 5 .7 0 0 0 12 g 1.* l H C 1 C 0 J C 1 Na 0 0 3 0 3 3 3 8 1 1 8 0 '8 2 O- ~ C 0 0 0 C F 3 ~ TOTAL 0. 14 23 1 3 0 38 O DERICOS CF CALH (No. OF HOURS) - 0 0 es TEMP. LAPSE PATE STABILITY CL ASS 0 V HIb0 SPEE0 VERSUS DIRECTIch (IN NUMedt CF CBS.) wit:0 wI t.~a SP E ED (M P H) AT 1C METER LEVEL O. DIRECTION 1-3 4-7 3-12 13-18 19-24 >24 TOTAL t.!!E .1 1 2 0 0 0 4 i:I O 5 7 1 0 13 ErlE 1 3 9 1 0 0 14 E 1 6 4 C G G 11 r* 2SE .2 2 6 0 0 0 10 SI 0 7 3 1 0 J 11 SSE O 4 4 0 C a g S 3 1 -3 0 C 3 .4 SSW C S 3-0 0 0 8 SW 0 6 13 1 0 0 20 O W3W i 6 8 8 8 15 w 2 6 11 2 0 0 21 WNW 2 4 C D 0 6 O '"4 3 J C 1 0 0 7 e N'!W D 1 1 C. 0 0 2 N i 4 2 0 0 0 6 O total 11 62 at 7 a 0 16e g PERIODS OF CALP t t:0. OF Houis) - 0 O . ~. %eN
.~Q. FPC - CRYST AL' 4IVIR 33 FT W!t.CS (OCL T) JUNE 1975 19 TEMP. LA PS7 4ATI ST ADICITY CL ASS i " O WID SPEED VEstSUS DIPECTIO:s (IH ?40MnE*4 0F CB S. ) ^ ~ hI2:D WI M) SPEED (F A H) AT 1C METE 4 LEVEL O DI c.ECT Ic N 1-3 4-7 n-12 13-14 19-24 >24 vCTAt t.?> E 2 12' 2 1 3 0 17 . AE 2-8 6 5 0 G .in DfE 2 17 5 0 3' O 24 ,g-' .E .G 23 1 1 3 0 31 ESE 5 to 1- .c 0 0 16 'O SE 2 25 2 0 t P, 29 SSE-1 6 0 0 0 C 6 -S-1 4 1 1 0 7 55* ' 1 6 2 8 1 8 18 O-SW C 2 4 0 J 0 6 WSW D~ G 7 C C C 13 8 1' 2C 1 3 3" O WNW G / 12 i G 0 23 NW 1 1 2 0 0 0 4 r, ht:W D 2 i C 0 0 3 'N 1 2 1 1 0 C 5 TOTAL 23 144-69 .6 1 0 243 ,e PERICOS CF CALM (NO. OF HOU'tS) C o TEMP. LA PSE RATE ST ABILITY CL ASS F O WIND SPEED VERSUS DIRECTION (IN NUMBEtt CF OBS.) O WIsc WIN 3 SPEED (MPH) AT 10 HETErt LEVEL DI;fCTION 1-3 4-7 6-12 13-14 19-24 >24 TOTAL h'i E 3 4 0 C C 0 7 'O kE 3 5 2 8 8 C 18 Er!E 1 7 6 0 0 0 14 E 7 21 C 0 0 0 FA O ESE 10 16 1 0 0 0 27 SI 3 15 C C 0 0 18 SSE J 1 C C 3 0 i S 0 0 0 0 0 0 0 g SSW G 0 0 0 C 3 SW D 0 0 0 0 0 0 g. hSW D G C 0 0 G C H 0 0 1 0 0 0 i W?sW i G E O O D 1 NW 0 C t C 0 0 C Q NFfW G 0 s d 5 C
- f..
3 i C e 3 0 1 O T TAL 2a 70 10 0 0 o les 'PERIOCS OF CALM (NO. OF HOURS) 0 O s-
.p e t - O . N. s 4 O e a e e b. ~.J y g > = - U- = > e aJ P" @ J M u es se u ett a s* c u og te N e e M CS -N Q A O Q 8"J Q O u e o 62 O O O Q eJ PJ u o CB Lg O Cf te t DJ N K. '.J l M.3 W (P MM 3 e4 e r2 r2 o o 's a es et a e,3 e 3 o es f3 o es 4 Lp - ,.J 2 ' m3 .gw. -- se - em (g. N - >= taa On - to 4 ' 41 4 >= e3 . M O, - g g ed' ge W. H e= res ~Z' CU - 4:,**O43 Or3 e Q w o o e a r)u o e oCa D, 4 tat et
- .)
h&. MM
== 0' k hJ ' ' >= en e-M d *N, s C.. 61 M - I es es W O' O. I.
- 8 tiJ E c1 o rJ se es e o u o u o es a w se o es e -
.= - M 3e J- ^ M. G - Q. 4 C. w'. .t. c ,a w M: bJ - W 2'. e IL - (L M Q. M. M tr ee -E- , O4 _ o
- b..
L.I O . =3 >= 4. M t O C' N A M M u u o e *J o o u o e,* In I .H og ' et '3' is O -La i e i .m.. a cg at. M-e, 8 J ee O W win et a f a e o O Q re e's O O et m 3. .J . > = ' .g M Q .,b-O' i b. O O a . ~ - g Q H-s a u. O. O 9- ~-. tas .ta. taa :,c - 2 3 3 e- - M 2 O b3 ~ et O _~~2 'le
- - P e t 4 O es) *:
M ta) M M 2 t,1 ~ ;t M 7* - O t% 'o % tY er. E Ad LsJ Lar 6; M n M M.s 3 3.c M M e-tas ' ye. g ~~ Q. .). a M," 'O - .x .O gO = , A' g M M g 4._' - @ M _ g% _ - M g = .. e ~ } O f9 M _O M
3 :- I .g 24 HCU4 SUT?A FV 0F WIk3 S A:E3 OIST9190 TION 19 T F FC '- C"tYJTAL. eIVE E 31 FT, WINGS (DEL T3 1/1/ 7 5-E/ 30 / 75 )' TCTAL NUMlER CF REACINGS 4.cA93 E+23 ) ~ TCT AL' AU:H ER CF 3F4 CINGS WITHOUT. CALMS
- s.. " S 5 J i, E + 0 3 y
~ WIND SDEEC DISTRIeUTION, k0 CF CDS.~ I*, LT.5 .50-3.5 3.51-7.5 T.51-12.5 12 51-2 .5 18 51-28. 0 GT-24.0 4 315 1568 17s8 434 58 2 3. y 5 SUMPED OVEv. ALL DIRECTIOFS WIND SPEE) DISTGIDUTION VERSUS T EMP. LAPSE RATC STABILITY CLASS (NO OF CDS.1 A D C D E 'F G y 1 ? L 0 G G 3 1 2 4 3 '4 39 86 107 76 3 127 20 69 328 551 326 147
- 3..
4 462 -59 110 537 444 61 15 5 127 13 23 186 .84 i C g 6 17 2 3 31 5 0 0 7 0 0 0 1 1 .G C e
- 2).
p. .')
,---_---a
- Q
- i
().
- FPC... C".YST A L TIV ER 31 FT 9ISDS (Ort il-1/1/75-6/3;/75
- 24 () O ~ s SUMrED DVEP. ALL TiMP. L AFSE 's ATE SinnILITI ES wit.D SPEED VE ?. SUS DIRECTIG A (IN NUM0dt CF C9S.) r, fin 3 WIND SPEED (M P F) AT 10 METER LEVEL OIRiCTION '1-3 4-7 8-12 18 19-2% >24 TOTAL A':E-28 72 61' 2 0 0 185 () ' NE, 40 9G 179 17 2 C 326 E*:E 31' 153 146 20 0 0 350 E 66 E2 3 . M3 11 2 0 374L (j . ESI 41 128' 55 1 0 0 225 SE 1E 178 77 11 J 3 282 SSE 5-65 S4 25 .1 0 15C S 3 SF 91 77 11 C. 24c -,;). SSW R 51 123 91 11 2 266 SW 8 52 113 64 3 0 24: ESW 7 78 1G1 13 G 199 q) u 9 141 240 26 1 0 417 W1W 8
- 92 172 27 9
3 298 t.H. 13 as 76 35 21' O 193 - () f.'19 15 47 38 7 1 C 118 1a 5 77 7 c 212 N 23 . 1568 1708 434 58 2 4185 TOTAL' 315 () "ERIOOS OF CALM t t!O. OF. HOURS) 4 () - 255 MIS SI rig OATA th0. OF HOURS) 0 O O C O ~0. O 1 L c)
l. -j ~. FFC.- CRYSTAL AIVER 33 FT WIkDS (GEL T) 1/1/75-6/?;/75 21 t- -l' TEHF. LApSr EATE STABILITY CL ASS A g WIhD SPEEC VC PSUS DIF tCTION (Its t1U W A CF 03S.) l '- EIND' WIhn SPEED (HrH) AT 10 HITEi (EVEL DI*ECTION 1-3 4-7 8-12 13-16 19-24 . >24 TCTAL ~ -ENE C -7 14 0 C C 21 kE 2 9 24 5 C-18 Et:E 3 E-18. 6 0 0 79 E 11 23 7 3 e 41 -ESE S-2 11 1 0 0 14-Q SC' 3 C-8 2 0-G 1r !SE 2 1 9 6 G 0 16 .5 0 3 - 14 22 3 J 42 -i 53W 'S C 34-29 3 0 66 SM - '? 1 11 12 1-C '25 ' kS W L 17 28 ' S 3 C 5" W D 44 148 7 0 0 199 g UMW 0 15 1C 14 7 0 136 NW 4 ?4 19 3 0 6C NtJ W 0 1 3 0 b C 4 g 0 7 13 2 0 0 22 t-TDTAL D' 127 482 127 17 G 753 0 PERIODS C' CA Lif (No. OF POUSS) - 9 O s TEMP. LA PSE K ATE STAnILITY CL ASS B hIhD SPEED VEtSUS DIRECTIch (IN I4UMBE1 0F CBS.) g hit:0 WikD SPIED (4PF) AT 10 METER LEVEL DIRECTION 1-1 4-7 8-12 13-18 19-24 524 TCTAL , ki3 E O O 1 0 0 0 1 Q kE 1 3 5 0 0 C 9 E'J E C 1 5 0 3 0 6 E 5 0 0 3 5 Q ESC e 1 1 0 0 0 2 SE 1 3 1 1 G G 3 SOE S 1 6 1 3 C 8 g S C 1 2 0 0 0 3 SSW 0 - 1 9 4 1 0 15 Sir 0 2 3 2 1 J e 3 hSW 1 3 11 0 0 v 15 W 3 2 5 2 0 0 9 W:4W a 2 2 0 0 0 4 Q kW D 1 2 1 0 0 4 NNW 3 3 1 2 3 0 3 N C 2 C 0 3 0 2 g TOTAL 3 2C 59 13 2 0 97 3 PERICDS OF CALP (NO. OF HOURS) - C C A M
- g.. ~ .y. FFC - CkTSTAL RIVEP 33 F T WI2S 'InEL ' T) ' 1/1/75-6/3?/75 . 2 2' r ,l I E M#e LApSr r ATI STAnILIT1r CL ASS C . WIA0 SPEED vcRSt:S DIRECTIOk (IN Nurai-1 OF CBS.) .{. b!!:3 'bII.C SPEED (MPHI AT ' 10 METdR L EVEL DIRECTION 1-1 4-7, 8-12 13-18 19-24 >2 4 TOTAL - f:;sE. 1 .1 3 0 2 5 NC C 2 7 2 3 0 11 .) ENE 2 3 6 1 0 0 12 E 3 6 8 1 -3 G 15 - ESE -C 3 2 0-0 3 5 ) SE C i 1 1 J G 3 SSE O 4 5 2 3 0 11 .S 0 1 6 2 C 9 ) SSW C 4 12 7 'O G 73 SW G 3 12-3 0 J 18 kSW-1 11 9 3 2 21 h 0 18 16 0 0 0 34 )- W'J W C 6 8 1 0 C 15 . f4W D 2 9 3 3 0 17 N:4W C 2 2 0 's D. 4 ); h 0 2 4 0 C 0 6 TOTAL 4 69 11C 23 3 0 209 ) PERICOS OF CALM (HO. OF fiOUTSI - 0 - ): S T E.10 LA PSE EATE STABILITY CLASS 0 WI AC SPEED VERSUS DIPECTIch IIN t4 UMBER OF CB S. ) WItJC HIN9 SPEED O!P > ) AT 10 METER LEVEL ) DIRECTI0tt 1-3 4-7 8-12 13-18 19-24 >24 . TCTAL htfC 3 7 28 1 0 0 19 3 NE 1 15 74 9 0 C 99 Lt!E 3 -12 49 13 0 C 77 E 2 27 19 1 s 9 49 + '-) ESE 4 12 11 0 0 0 27 SE 2 P9 33 5 C 'J 69 SSE 1 17 24 4 1 0 47 3 3 17 24 24 6 0 71 SSW 2 29 42 38 6 1 118 'SW 5 34 66 41 1 0 147 3 bSW 2 24 38 3 G D 67 W 5 la 35 14 0 C 69 M4W 1 24 39 10 2 0 72 Sd 6 18 -21 17 14 0 76 3 NMW 2 9 13 3 1 0 28 N ? 19 25 3 0 0 47 ) TOTAL 39 328 537 186 31 1 1122 ).. PERICOS OF. CALP. (t:0. OF HOURS) 0 3 ..)
M: ,1 d~ FPC -'CtYSTAL RIVED J3 ' FT ' WI t.DS (DEL Tl 1/1/75-W.tt/75 23 e' TEMD. LAP!r G ATE STA?ILITY CLT.SS E 'g . wII.D SPE ED VEPSUS DIREC TIch (IN NU"PE3 CF C3S.) WI t.3 W!k3 SPEED (EPH) AT 10.METEA LEVEL ~g' DIEECTION. 1-1 6-7 8-12 13-18 .19-24 >24 TCTAL k? E 24 2. 1 C 0 49 NE O 25 57 5 L 0 91
- 3
.ENE-6 4 'l 39 0 0 0. 85 E 15 63 25 2 0 C 1*C !SE' 11 50 27-S 0 So Q SI -2 A1 32 2 C J 137 SSE 1 32 1C 12 C C 65 5 3 3?' 45 29 2 0 111 + SSW 3 17 26 13 1 1 61 SW 3 11 21 6 3 41 >SW 3 23 15 5 J 0 66 5 4 42 35 3 1 0 85 ,3 kNd 3 35 27 2 0 0 67 NN-5 15 '2C 5 1 0 SC j f.t1W 7 27 19 2 0 0 55 N 7 30 26 2 0 0 65 TOTAL 86 551 444 84 5 1 1171 O PERIOCS CF CALP ( 11 0 OF HCU1S) O O TEMS. LAPSE R ATE STADILITY CL ASS F kit:0 SPEED VERSUS DIRECTIOh (IN NUMBfR CF 003.) kIVJ HIh3 SPEED (MPHI AT 1G HETER LEVEL DISECTIOt1 1-1 4-7 8-12 13-18 19-24 $2 4 TCTAL brJE 10 26 12 0 0 0 48 Q NE 15 23 10 1 J C 49-Et:E F 55 25 0 0 3 87 E 28 71 1 0 C C 2 C C-g ESE Jf 44 3 0 0 0 65 SE 5 54 i C 0 0 6C 'fa SSE 1 9 C 0 C C 10 0 S e 3 C 0 a o 3 SSW 3 C C 0 0 0 3 SW 0 1 0 0 0 0 1 g-WSW 3 0 C D 0 J k 3 0 1 0 0 0 1 W:W 4 ( C L 3 0 4 g kW 1 3 0 0 0 0 4 AtlW .4 7 C C C D 11 t. 11 3C 8 C C 0 L9 g TOTAL 107 3?6 61 1 0 0 495 O PERIODS OF CALH (t:0. OF HOURS) - 3 O t3 ./
'y tg FPC ~~ CtYST AL *IVER ' 33 FT WI"3S '(CEL T1 1/1/ 75-6/3;/75 24 .l . TE:4 58 LA ESE Rt T F.S TA'JIL ITY CL ASS G g wit:0 SPcED VE95US DIPECTIC A (IN NUH3dR.C.C CBS.). O ~WInc wit.S SPEED tHFH3 4T 10 MITEn LEVEL ' 3;' DIRECTION ,-1-1' 4 B-12 13-18 2C-24 >24 TCTAL HGE
- 10 '
.7 5 C 0 0 22 EZ 14 13 2 C C 0 29 3: E:E. 13 37 4-0 0 C 54 ? 'g .E 15 42 2 t-t- C 59 ESE 4 .16-C G G 0 t-24. j.. SI' 6 13 '1 'o 1 0 20 SSE 2 1 4 0 0 0 C 3 5 3 1 C C u 1 ]. "SSW-O C-C e G C .!W. 3 C C 0 0 C WSW 0 0 'O O C 0 0 ^j W G, G G C. J C C MWA ' 3 C E C C C 0 kW ' 1 i C L C' C 2 ~)- hMW 2 i C-0 0 0 3 ~ N 15 1 .0 3 3 21 TOTAL 76-14 7 15 0 0 0 238 .') ' PERICDS CF CALM (NO. OF HOURS) 1 g O* e O- .3 0- 'O e 'O ') 4
, e.gf y < w.,.. ~..m.e, 1. . ~.. v - --.n r, ,.n~;, .~.r.m,...-.nwe v.~. - na y._,. 7 : m.,; v.:.. r..m.,., m. y s s u- ,,a. s. .m e.,'. n. ~ ,t ~ . u_ y.. A m.: y 9 / r 4 is ? (; y y y,- .t 4.. f "3 E .j .4. - y*
- ?.
s
- r..> -
c. n .a .s. s .~ s e .b ~ .c e. s .i.r...
- 4. ?
e, .i .~ '+' ,w ..y 3 .,,g Q_ f.- J 4 j 'Q";g Q;, a. s.. I;) I;wM,r' M.hl, '% f I* h l'h h Q h',, h +*-a .$? g ' al. A.c@,. v' y. y Jm[">[w.h s - [k' f* I^ "; 7 '. ffINs--[. .[. y.- gpr. g yo.'. jm :, %w m y yf.a,,.. p wp.n m, g yg.~,,., ~.gg,e,;g. 4.,Q. m., u m. en.y.3. qu.,in 3 d,:, T Tg a h% nh,.,. t _,.. f.7;o,,, pd g,yDeug m 3.. A q + N 9 .q. . ypfj. W M f f (q 3gh'h
- kh
..a gr sfrph 4 h Ui h h h ;~yu?y4 4.g %vupp.p y. p ympyy;..x n; u)q (gQ,h,y &y &m.c g
- % p,jy ;y 4e;W
- a.pp m z
G / m e bcg*g,e.:.up,c+ ,c.n %;m y u,+g m pM rafr.:p nwwwn .m. a o y;ce~ .~. Q m w W wvmcF we.es D.Q,p, m. ym M .gv,. i,Wyd.. s 'M,s,.y dggWg y m. gs - y L e % g. Q W W g M w e: t +.lmgy,.sM;..c, k agay.f,e.p. n. gp.,,.,4Q e p u y @g. g,..,.,n cg %, r,cW ,cc H w+..-. < g ry, m j .M., r O. :3! 3 j p .v %.s.v s:m-e.,.
- ., q.
.y ,.~.+. yp.,),A, n a m.x.:. #, m",n-Y~*'"',' PENDIX 'a,C;..W..; 4 q;^,7yt
- a. > e ?.. t rs..
. g. a. 3,;, *, ~ ~ e +a.4,g, r. :.; g, n %, - p'+ > ' 4y.yy n. c g .~ ~ w.
- 1.. a s..
g.C,4 p.a'P. f", j y,..~ i,~, , rn p o ?h 5 %. r>F@p.W. p.,on. th.}y:;a..nd.. E8.1x4M.onth J<ohtt3requen. 4.h. e MMM.y%. W PPM -. .but s y 4 .g-m &,q s paa r y... .a ~.n w u. a w . w;. s.f..fy%,p Wih.,M. :s.tri,Fe..,io,n. x'of fW1n.t.e *M,C..draiA.,;p I w.ppte.: D., is . tii h,7fe,',r'Bae4(a . i( $.%g ^4@ @s ..e.3 r f-e w eu m .w n J dp2 .m; /.Qx. - W,? ejMY,MW ' Di e. ,13: -, _c c _x :3.4 4c.W;,v,, z. >..p, % _ws wr asses:
- g. A de
- .m
...-m .n. ,p iRW ,Stabillt. Ci Basedong.for th,e'.33-fd,, g v, gg.<,,. m.:,s. p.mq,m,1 3. g%,. +. %.wn < s -~..%e,w. ~ v,v y w.ww %. r %qa, .a m. .. u w..s. -'.[ 'w-x $o.., a%. %m 4 n
- i w g-s 4
t e >QQg#1 f VU. G.Q, Q ip @ Q Qf Q Q a,
- 4
'"';..,a 4 '4 / .t 1.83 p
- d 4, p.biY h*'
'4 3 b'%. f* #tp i 4 } ;e,e s A, f 'h k. I l' W,',,..',..Wg ' ),M' p ;*,;'k* p j e ,i f.3
- i...
- ~
'*I ' a S -- b , Q # ["q 4 @ h-e d '. t s1 q s@, } c og 44 44g ge g as, j .,q._ g p
- a_t, wp
,4 p, ' *Y'iQ$d&pyL M,&j.,;E p,&. &. ,,.A,.% '. c.u 1.. A ~ A $@4rg[;Al.W G yf9 M F " p@ s &q$*Q(f .ghyq*W;h W;.A t-v s rM ENsM s$ M; Q,f IC h in. - -- m m utay n@m y 4, i M me$fw g p V t H g %w g p r g sk % w g ~d y gf. g. v b y e w m? p., s se eew % :. % M y y & w.g w i Y.p. a p .p. 767ep g u. m ~ .~ nww w n e w.nca. _w w w m a~m,eu~n,1 ane. - megamw%pi n.m m%,>_ w. .tw y w~ a... A,.w.j. p.y.9....o
- g. % % - w /
e. ae 4
- ,s.-
,p m, .t.
- 3. s ~
my - ..e-4r s , s
- - x g.py Qp' fa >
". 9,f, ,,.3-4 yi J1 s ~.. ' ' Ut .,r,- ~ 4 - -. $ g t,. i f c . i k 4 z 2 + o
- b. #
1, (.g J V. 'I M #' f,. ^h.j ,;D .4, i '4* g.'.' -&J ^~ '6-- te o 4, N z.m y, 6 m .j 4: . :4, ;g-
- ,.., g e,
, - if,, y.
- m. ;.:,.,y a,
w. -sh - < 4
- gi
- w y s
w e.,r ;e 7 * *. ' M ' g .? + -m
- c.. g, 3, g.. ~
yp %4 a %q. s r.:- i* 7, f.m".V v 9 ~., i "j., -%,.,.*>. -). g 2 4,<3 mg c V ._.y s.. e-.. %.n:]. t yI.., ~. ' \\.
- g
%^ q
- .~..
, ;, y...,, ve:... s f- - j, 4 ,. f d'h. Y' '* pN4 $^ We Y.e k:, Y Y ?,} ~ ' f ? 3 'A. R f ^{. ~ i a' a w e A. - ** ) ):W. +1. m. e..q ga afi, .ps 4 g.-,g.M...a.e 4f < y v p y:j.Q* lm'
- g,%.y/*.% 4.q p.
+,'o,Mw w, 4, y.9..M. i )Q')/,;. w e-+.,. Aq.Y'..,r,.Q <. n - m,+. m p o + w=,t 4 le - _ ,u s f
- y. v, p?% e:,0 f f f ryR, ;f, ; Q ^w_ e., %1'..my,?[x
.y e p-y %-). -s _ p 4,&d, > \\ '3 y 7. mv v.s. p*.s. -.4, p] - : -..y v,.c% ;;4.M - 4,t<',w'* J &o .- p > e n a w . s i p r.,- e ap n.y.et. M.f,t s.cM. -1 h;,y.,. v e%'.:f,c Q. ~ .,a,v. A n:p s.; m& n ~. -g., : - s~-
- 4. k. i y 4
,4 M, W m%$ f5 p.mw n v. s ~ h :- v y' Yhdy- :e s ( h.e [%w*F m g k, h h. jh
- ,.p, h
ym[ph.f i%*m y g[ pa s fyg g e u a mwmesa maqag a p 1
T.V l. 33 NUS WIND DIFFUSICK FRCGRAM (WIN 07ANE) 't
- t 4
33 FT WINES ISIG THET A) (). 1 FPC - CETSTAL RIVi2 r -. g SE A03M ItdEX 1-a M A, A P1, MA Y a ) . ) SE ASIN INCEX ' 2 = JUN,JUL, AUG SE t.0')N It!CEX 't =. !E c,CCT, r;CV () - TEAS 04 INCEX 4 DEC,JAN,FEB - ;) WI13 SPEE0 GROUP D ESCRIPTI CN GROUP WIAGSPEEG RAbGE(PPH) e). 1 LESS THAN C. 5
- 2 C.50 3.5
~() J 3.51-7.5 4 7.51-12.5 5 12.51-15.5 . ()- 6 18.51-24.G 7 >24.3 .3 , WIND' SPEED GRCUP EQUIVAL ENTS
- f to:41 CALM 1-3 4 8-12 13-18 18-24
.GT 24. -().- PP4 L T 1.9 D.5-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.3 GT 2 4.C rp S LT J.2 c.2-1.5 1.6-3.2 3.4-5 6 5 7-d.3 8 4-1C.9 GT 11 0 Cy KYS LT J.4 c.4-1.0 3.1-6.5 6.6-10.8 10 9-16.1 16 2-21.3 GT 21.4 ') ST ABILITY CLASSIFICATION g INDEX CUMEIPTICH 1 EFTP5HrL Y UNS T AB LE g) 2 UNSTaSLE 3 SLI f1TLY UNSTABLE 4 HEUT'AL () 5 SLIGHILY STABLE 6 STAPLE 7 E XTPIPZL Y ST ADLE O () () O oC) C) G = -. _.
..O ' .' 2r.' FOUR SUM". F Y CF wit $) S*IED DIST kIEUTION 16 O FPC - CRYSTAL LIVER 13 FT WINDS (SIG THETA) JAN 1975 s . 'TCTAL NU1121 CF.REAOINGS 7.410CaE+02 C.. TcTAt Auvice CF aEa:IxGS W:Ta0ui CAtxS 7.ciccoE.c2-i- O' O ' WIND SPEED DIST4IBU TION, h0 CF CBS.- 0 - LT. 5 - .50-3.5.3.51-7.5 751-125 12 51-18 5 1s.51-24.0 GT-24.0 0-56 2 70 294 97 24 0 0 g O SUPMED DVER ALL DIFECTIOkS WIND SFEID DISTRIBUTION VERSUS STABILITY CL ASS (NO OF CBS.) O A 0 C D E F G 1 C C 0 0 3 O 2 0 3. 3 23 17 9 4 3 -1 5 22 97 sa ss s 0* 4 1 1 13 104 157 18 0 5 0 0 2 22 67 6 0 .O 6 s 1 t 2 2: 2 0 7-0 C C C 0 0 0 4 O O O -Q ~ O L 9 O m 1- ~. -... = - -,
-t. . i, ;.- 'g. ~ FPC :- CRYSTAL EIVER 33 F t WINOS (SIG THETA) J A".31975 - '16 i O .O ,g. SUMMED OVER ALL STABILITI2S ~ WIND SPEED VE RSUS DISECTION (IN NUMBER CF 095.) O-6Isc 1-3 4-7 E-12 18 19-24 >2 4 TOTAL wit.c S=EED (MPH) AT 10 MET ER L EV EL - ' DI R ECT IO N Mii-7 1C 21 0-3 C 38 'O' xE 6 Zs 65 to c ice ENE -5 -. 3 8 40 9 'O O 92 E 11 38 11 C 'C 0 6" g ESE. -4 11 C C E 31 SE ? 17 16 4 0 C 4' SSE 0. 6 11 16 1 0 34 g 5-2' 14 27 33 7 G 22 SSW 3 10 17 5 4 0 39 SW 2 13 7 2 2 0 74 g, FS W i 15 6 2 J 3 24 h 1 14 7 2 0 0 24 kNW 2 13 15 6 2 -C 4C nW 0 1e ic 6 is e 36 O. M4W 4 11 1* 1 0 C 26
- t. '
6 15 20 1 0 0 42 O T TAL 56 270 2 96 97 24 a 741 4 O PERICCS CF CALP (Nn. OF HCURS) MISSING 9ATA (NO. OF HOURS) 3 O O O O O .O O. O -=
g FPC'- CRYSTAL AIVEP. 33 FT WI A35 (SIG THETAl JAh 1975 17 T A9ILIT f CL ASS - A O IhD SPEED VE/ SUS DIi ECTIOk (IN HUhAEt_OF'J~lS.) -e kIldC WIND SPEED (HPH) AT 10 NETF4 LEVEL j0 0:cECTIon 1-3 r.- r. a-12 23-1s 19-24 >2 4 TcTat. 9112 3 C 3 J O' E k" '3 O O 3' C g ENE 0 0 0 0 0 0 0 E J C [ C 3 0-C- ESE e O C C J c C g 'SE C C ( C C 3 3 'SSE C 0 C 0 0 0 S. 3 0 1 C o 0 1 0 SSW c 0 e a t . SW D .G C C 0 C S ESW C 0 0 0 3 -C 0-8 8 8 8 8 8 8 O Wr:W G C 0 0 C ? NW 2 2 C C G E 2 a NMW G 1 L 0 J G 1 V' k 5 C C 3 J 0 0 TOTAL 0 1 1' C D 0 2 'O PERIODS CF CALH (No. OF HOURS) C O -Q ST4dILITY CLASS D WIhD SPEED VE< SUS DIRECTIch (IN NUPDER OF CSS.) O wino WIteo SPEED (HPHI AT ic HETER LEVEL DIRECTION 1-3 4-7 8-12 13-13 19-24 >24 TOTAL hi!E 2 0 0 0 0 0 2 O
- E c
1 C c c c 1 ENE D 5 0' C 0 3 0 E 0 C C 3 C C- 'O ESE C 1 e C 0 0 1 SE o O C C 0 0 0 SSE C 0 C C U c ( g S C 0 C 0 0 C D SSW C 0 -C D G G 1 SW 0 9 0 0 0 0 0 O x,w 3 2 i O o O 3 W C D C D G 0 C WNW 0 J C G G 0 t hW o C C 0 0 0 0 O ANW 0 1 0 0 0 0 ,1 N 1 C C 0 0 4 1 O TOTAL 3 s 1 C a 0 9 O PERICDS OF C A L P. ( Ht). OF HOURS) 0 O j o
jQ .=FPC - CRYSTAL.tIv2F, 33 F T WItCS' (SIG THETA) J A N 1~)7 5 18 ST ANILITY CL ASS C Il O. WIxo SPEEC VFRSt.S DIRECTIC A (IN NUMBER OF CSS.) '41 *J3 WItM SPEED (PPHI A1 ric METEt LEVEL ,g. DIGICTION '1-3 4-7 5-12 13-18 19-24 >2 t. TCTAL . f.N E 2 0 1 0 J G 3
- bE O
4 2 C 2 0 6 g. E':E O 1 1 1 k 3 F 1 L 2 0 2 6 - .3 ESE C 0 0 0 0 0 .g. SE O 1 C 0 3 0 1 ISE O 1 G D = C-1 S O C 2 0 0 C O' SSd C 2 C 3 8 2 Ed 0 1 G 1 C 3. 2 hS W' C 4 '1 0 2 C 5 - 3 ~. H ? 3. O s s it i - Ft'W D 1 2 C 0 0 3 kW. 3 6 C 0 o' O O 'bHW- 'J O' C .0 0 0 9 ' N O O 1 0 w C 1 TOTAL 3 -22 13 2 0 C 4C 3 PERIODS OF CALM (NO. OF HCURS) t O .Q ST ABILITY CL ASS D WIND SPEED VERSUS DIRECTION (IN HUPDER CF 085.) g- ' EIt:0 ' WIhD SDEED (H pH) AT 10 METER LEVEL OICECTION 1-3 4-7 8-12 13-18 19-24 >2 4 TCTAL ht:E O 1 14 C 0 0 17 0- "I 29 3: 5 C 58 ENE ~1 E 12 4 0 0 23 E 3 12 5 t 3 0 2; g ESE 1 5 3-0 C C 9 '!E 2 6 6 2 G 0 16 SSE G 4 4 2 1 3 11 0 S .1 6 4 1 a 0 12 SSW i 1 3 1 0 0 6 SW 2 3 2 0 0 - 0 12 g kSu 1 9 4 2 a 0 i t-k 1 6 4 2 0 0 13 I. Et!W 3 9 9 3 0
- 0 21 C
1 1 G 1 8 3 O f.N W 1 G 1 0 2 0-2 2 2 2 0 0 0 6 T TAL 20 97 104 22 2 0 ?ns O 3 DERICDS De CALM (NO. 0F HOURS) - 0 O -l l
T- . f '_ * - 3 FAC '- ClYSTA t RI'tEC 31 F T wit:30 (SIG THETA) JA;3 1975 19 (' . ST A1IL IT Y J CL ASO F ')_ kIKO SPIED V::ESUS DI2ICTIDk (IN NUMEER OF C83.) WI AC SPEEG. (MPH. AT ' 10 ' MdTER L EVIL hit:3 .w DIE 2CTION-1-3 4-7 .4-12 13 19-24 >24 TCTAL M:( 2 4 6' 'O c' O 17-tE 1 4 29 5 C C. 29 Er:E 3 13 23 4 3 C 45
- ~
E-5 .22 2 C 0 0 19 ESE' 2 7 '8 C 0 0 17 ) Si. 0 9 9' 2 C 0 2; SSE - 2 1 ~ 7 14 0 C 22 -S. 0-7 l22 27 7 0 61 s 30W 2 7 14 3 4 0 3C S4 0 4 5 1 0 0-10 WSW
- C-0 0
J G h C 1 3 0 5 C 1 ) W!!W 1 5 4 3 2 C 15 kW C E t 6 7 0 25 ) MfW 0 6 9 1 J 0 16 N 1 1C 15 1 0 0 27 TOTat 17 94 157 67 23 G 359 ) PERICOS OF CALM 1H0. OF H00F:0) C } e ) ST A 3ILITY CL ASS F WIND SPEED VERSUS dis:ECTION (IN NUNDER OF CB S. ) } WIhD WING SPEED (MPH) AT 10 NETER LEVEL e DIRECTIC. ~*-3 4-7 8-12 13-18 19-24 >24 TOTAL AME-a 3 0 0 G 0 4 g EE S 4 C C J 4 CNE 1 13 4 0 0 0 18 E 1 11 2 C e 0 14 ) ESE 1 3 0 0 0 0 4 SE 1 1 1 0 0 C 3 SSE O C C 0 0 C C e g S C C 2 5 C D 7 SSW G 3 C 1 C 0 1 SW 0 0 0 0 0 G C hSW C 3 L G C 0 C W 'G C 0 0 4 0 C 'I kNW' 1 0 [ 0 0 6 1 kW C 3 3 0 2 0 8 3 MtW 2 2 C 0 3 3 4 N 1 3 2 C 0 0 6 ) TOTAL 9 39 18 6 2 C 74 g_ PERIODS OF CALN (NO. OF HOURS) C e ) e ees eee weseg e me ewee esposeer e e enim som o mese m que see mese=== e-e + ee e==ese o e o e
- e
f 1 -w, e' N_ = i e e e eJ d i. O t >= c e4 M J u s u e4 ca o 4.* o s u N e4 N et e. e M 4 P As O A u u o o u ta es e.3 cs en u o o e es o c's y 1 w se e 4 (3 N, E.. J D N F.e a n s a s as.s rs es u n rs o ns u ra a o 3 me W' LJ A -2 J e n t en w er
- i. e i
A E a= en . se C '***-e e I 7 64 T. e l ) t-to U U e4 *a to o en ss u o o o u u o a cs o es o - at hs e4 I ) i W M O - 6= 1 2 l ) MM O LS.~) ...m N 'a w at u - J. e u .' M of 0.* & 1 e
- , W 'el E c u u O ed u u u o e u 8J O CJ u 43 u O l
en > O se C O l 4 Mw w M ' 4 *J kf 2 H ft 'a M e ca M M O' i D= P 3 m -o o ,m u - l MM 4 J ta O P) P'B - 3 u O eg r., ss O O C ra et e1 eD Z M .N-- H i I M' X '.'E la. O j tt I I w C f M 2 -W m. l = eg o e4... .a. o., rJ u o, o e. -, r a > =. e.g n-u s= - L w O w O 2 I o m I- -J n auw .O [ o . w w w-2 2. 2 x-4 g. u -w=w=- m i.. n exn nu O y A E7 4 4 W tse we n t e W M O.s 2 r f. z d p. taJ I M O I. ' 1 l s D ;.0. :-0 _O. O l O. ' O; : O
- D-. O O
.O O O.O O O O0 0 0 ......~.i.~.,
!{I -\\, Q- \\ 3j dF WIhD SPEED DISTRInLTION lt s\\ - 24. HCUR SUMMACY jl O, j-F CC - CRYST AL GIVER 33 FT WINDS (SIG THETA) FEB 1975 > j :. O TCTAL NUM3ER CF 4EADINGS b.16 3 3i d * *2 .I j.O TcTAL. NU'11ER: CF REACINGS WITHOUT CAtt's 6.18GJGE+02 .g f' 'O
- 'l
- 0 WIhD SPsED DISTRIBUTION, A0 OF 085.
iO '} LT.5 .53-3.5 3.51-7.5 7.51-12 5 12.51-15.5 13 51-21.e GT 24 0 O 53 236 220 '97 12 0 0 0 OO a . SUMMED OVER ALL DIRECTIchs I WIND SPEED DISTRIBUTION VERSUS ST AEILITY CL ASS (NO OF CDS.) f'O A e c 0 E F G 1 C C C 0 L 0 C 2 2 3 1C 15 13 8 2 i O 3 5 7 36 1s 88 22 2 i 4 1 3 20 89 104 3 0 5 1 0 2 17 77 C C l0 s e 0 1 s 5 c c 7 0 0 C 0 0 0 0 I tO 9 ..l .g o IiO I
- O t
10 ! O
- l..
4-0 O
.m .Q FPC - C,tVSTAL EIVE:t 33 FT WINOS (SIG THETA) FEE 1975 17 O.
- 3'
-SUAPE9 OVEP ALL STAGILITIES WikC SPEED VE RSUS DIFICTIC A (IN NUMEIR CF 08S.) ' Sinc uIko SPEED (mph) AT it HETIR LEVEL 'O 'CIKICTION 1-3 4-7 8-12 13-18 19-24. >24 . TCTAL hNE 5 14 11 0 G 3C-3 kE 6 14 21 2 3 0 'S ENE 5 25 21 7 0 C 58 E 1G -19 'S 0 0 0 34 ~O-ESE 2 16 P. 1 G C 27 !E 1 12 it 0 0 ?9 SSE 2 9 L C C C 14 g 5 0 13 '23 18 0 0 54 SSW 1 14 '24 34 2 75 SW 3 6 11 14 6 0 36 'O. i 22 2 3 8 ' 29 E 1 31 20 2 1 0 57 W!!W 2 16 28 4 0 5t kd 5 10 is. is a ce O khw 5 6 3 3 1 0 18 A 3 17 6 0 'O O 26 O' ~T T^' 53 236 22C 97 12 618 PERICOS OF CAL:1 (No. OF HOURS) - 0 g, HISSIM D ATA (t:3. CF HOURS) - 54 0 'O O O .O ~ O O O ,3
3' FPC .CtYSTAL'RIVEP 33 FT t:IkDS (SIG THET A) FEB 1975
- 18 ST AEILIT Y CL ASS A
,g WIND SPEED VEESUS DIR CTION ( At! NUNCER CF C95.1 bINO-kIkD SPEED (NPN) AT 10 M2TER LEVEL 3 OIRECTION 1-T f.- F 8-12 13-18 19-24 228 TCTAL AME ~ C 1 0 S 0 0-1 . h! c 2 0 v u 2 i..,' .O ENE C c 0 0 0 0 0 E ~3 1 0 0 3 0 1 ESE J -0 C C 4 0 0 Q -SE O O 0 3 0 C ^ 4 SSE 1 0 1 0 6 3 1 5 0 0 0 0 ' s, 3 J g; SSW 9 C. C C C 0 Su ? C C C 0 C C kS W D C C 1-4 C 1 -h. '1 1 0 0 0 0 2 Wi!W 0 3 C 0 J u 0 kW 1 0-0 0 C 0 1 g kNW 3 C G C 0 J C k 5 0 C C 0 0 0 TOTAL '2 .5 1 1 C 0 9 'O PERIODS.0F CAL *f (NO. OF HOURS) C O ' ' O ST A9ILITY Ct eSS e WI AC SPEED VERSUS DIRECTIOk (IN NutleER CF CBS.) O WIND .WIhD SPEED (MPH) AT 10 METER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >24 TCTAL kt:E O 1 0 .0 0 0 1 Q t:E 3 2 0 0 0-0 2 ENE S 1 1 0 0 0 2 E-4 L C 0 0 C C 0 ESE C L 1 -0 0 0 1 SE O O O O C 0 0 *e SSE C 0 C C 0 0 0 3 S C C 9 0 C S SSW i C C 0 0 0 1 SW 1 0 0 0 0 0 1 "3d 8 2 C 0 G 0 2 O W 3 2 1 0 0 0 3 WNW i C C 0 0 0 1 g kW C L 0 0 0 0 0 kNW 0 0 0-0 G 0 G N O L 0 C J 0 0 g TOTAL 3 7 3 C C 0 13 ,], PERIOGS G~ CALP (NO. OF HOU95) 0 Q .O -=
4 g.. r f,0 ', W. T M L c l'* Jf' n ft % I :n t'. ("If f osfitt FCQ j eg e.
- ',9 ST a t1 L IT Y CLt.0*. ' ' r.
' ~ ... WI !:f) Wrm v<rMji otssCTint. I l!. Wynr? 07 C*t t. ). y ' i !!C .} HYW SOCt0 (?'JM) ' A T 1' H E T E ~. ' s,5y e~ L 3. D I.. r.I I C f. 1-6 r,- / st-17 1.5 tw-?A. 24 TrTAL ~ ^ * ' r.k l. - 1 ? 'O. 0 0 C 3 fE 1 1 .1 C-C ') .y - ( *! E 2 1-1 0-C G 2-s- 1 3 L 1 E. - "it. C 2 1' o 0 3' Si. '1. O^ 2 0 S 0 3 SCE C C C^ 0 C C S 1~ 1 C 3 s ? 33 1 [ C C 1 Ok 1 0 0 C J G 1-e .. m a 'd 4 2 L C 5 W C 25-it 1 1 0 37 kv4 f. -C 0 J L C AW 3
- 1..
1 0-0 0 5- -) %*! h, C J G 0 iJ. 1 c C-0 0 0 1 TOTt u ' 1; 36 26 2 1 C 69 720I30s of CAL:1 (NO. OF HCU45) C .g. es e e eee eee sve...eee e eee ee e e ee ee ee e e eeee e ST AJIL IT Y CL ASS 0 WIhD SpliD VIREUS DIPECTION (IN NUPSCR CF CBS.) .a hI!3 kIh3 SPEC 9 (P DH) AT 10 METER LEVEL 0115 CT IO N 1-3~ 4-? 6-12 13-18 19-24 >24 TOTAL M.E 1 6 3 0 0 0 10 NE 4 6 7 0 G C 17 E:'E 3 4 4 0 0 0 11 .C 3 2 4 D G 3 10 iSE 1 3 1 4 G 3 5 SI O .6 12 0 O-16 SSE C 6 3-C 3 0 9 g S 0 8 11 4 3 3 23 511: 0 3 4 3 C it S:4 1 5 3 2 C C 11 WSW i 7 2 1 3 C 11 C S 9 1 0 0 15 a Wr!)4 C A 19 1 0 28 Ad 3 2 4 4 6 0 16 N1:W i 3 3 1 3 S b 4 2 0 0 0 6 .3 70TAL 15 76 89 17 6 0 203 PisICOS OF CALM (NO. OF 400.1S) C / ,,m,..%.. ..,em.,. w J
m
- 1: O
.F90 - CRYST;.t TiIVEP. 33 FT wit:05 (SIG THETA) FEB 1975 2C ST 4*)IL IT Y CL AS9 E t O. .WInc SPEED VEPSUS DI AECTIC A (IN NUPEER OF C35.) ,g - DI AECTION WIm SAEED (7:P H) AT 1C METE.1 LEVEL i WIN 7 1-3 6-7 6-12 13-18 10-24 >24 TCTAL ht:E 2' 3 8 0 6. 0 13 kE 3 3 13 2 0 0 la .O EHE-1 12 13 7 0 C 33 E 5 11 ( C .] 16 ESE, 3-10 G 0 C. 14 O-SE 8 8 0 8 8 1 t' SSE O 2 i C J J 3 S C 4 11 14 3 3 2a 'O SSW G is 26 31 2 C E3 SW G 1 8 12 0 0 21 WSW -0 J 1 0 1 0 1 W C C C 3' 3 0 .; g Wi!W J 6 9 3 G c le KW, 1 6 8 6 2 0 23 -l9 NNu 2 6 C 2 1 0 11 N 2 ib A 0 0 16 TOTAL 13 39 1t4 77 5 3 287
- to 1
PERICOS OF CALF (HO. OF hours) - C !o } O ST ABILIT Y CL ASS F wit 40 SPEED VERSUS DIRECTION (It4 NUMOCR OF OBS.) I SIN W I t. SPEEo : MPH) AT 13 METER LEVEL O DI ECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL I f:ffE i 1 0 0 0 2 .lO NE i C C D 0 i E r:Z ' 1 6 2 0 0 0 9 E 2 3 C 0 3 3 5 $-O SSE G 3 G C 0 C 3 SE J 2 5 C J C 2 SSE O 1 ? C. J 0 i s o o 0 0 0 0 C ,' O SSW S 0 C C J G f I' SW 3 0 C 0 0 3 C
- O
'3" 3 C f 8 8 8 C l W D 0 0 0 0 0 0 W':W 3 2 0 0 0 C 2 'I O "W i i 1 8 8 8 3 s NNW 2 C 5 G 0 0 2 ] h 0 3 0 0 0 0 3 O TOTAL 8 22 3 0 a e 33 l ! O PERIOOS OF C4LM (tF). OF HOURS) C t
- O 1
O
ee N s t l e e o J et Le
- a to N t og u ts u e.e a u Q v4 o u 8.* J 4
e M J
- TR N
O A o u E3 g;p a g el o (* o G 'J r) f3 es e3 u I LL U s tw tsJ J l w _. N. I D wm e L > ** O t14.3 e e o e s es r,.J o o CJ 4 3 o ts u c3 [ IA .o E .J g so w w &W ED A M eD hJ O he v4 4
- 4 E4 M
a O rs ce o o c.s a e e c3 u o u o s3 e e as u a u o a w e C as W H I 3 s W as L'e &# 0 11.3 e N,4 N ut 61 e o M J ta ae w Ut-
- 7. 40 si cJ 4.*
, e e u u ca s.' o o v u sJ u o ca w t1 -c O i o t -m w M eW W se. g 3 M CL M 87 M M cc, l = 6 8.* C OO O s M4 2 4 o rJ N (2 a o s e as.J o a u o u o e4 N 2' } m w i P3 E 3 L6 O of h. C H g s fr M. J w .c o o n o - o u 3 o n., - u o., N x. a. +. 4 o M 16 O O 2 e 8 O M N a o o e e-u .s
- o, :.:.o = m.o...., u, w
.o 2 .x x w e e2r =x2 O .u a. .: eo m m w n n 2 2 <. e.: - o l H 0,. O 1 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O^O O O O O!, t**.999e* W w eme w r
.. s >Q . t j' 24 PO'JR SUMMA FV 0F wit.0 SPEED DISTFIOUTIDM 17 lO RIVER 11 FT WINDS' (SIG THET A) MAk 1975 FPC - CRYST AL '-'O TOTAL NUM3T4 CF 9EADINGS 5.94000E+02 .g TOTAL'NUM3ER CF RE8CINGS WITHOUT CA L PS 5.942CJE*?2 D O wit 1D SPEED DISTRIBU TION, NO CF 00S. LT.5 .50-3.5 3 51-7.5 7.51-12.5 12 51-18.5 18 51-2%.C GT 24.1 3 24 174 278 105 13 0 0 p ........e..e...................e........ J O SUMMED OVER ALL DIRECTICAS WItJD SPEED DISTRIBUTIOff VERSUS ST A3ILITY CL ASS (NO 0F CBS.) A 9 c o E r c O ~ 0 C C C 0 0 0 1 -2 1 2 4 13 4 2 1 3 3 5 21 52 82 11 2 - g 4 2 it 52 121 92 1 0 5 0 1 4 53 43 4 0 6 3 C C' 7 6 3 C .7 C 0 0 0 0 C C O O O O O O O. b
5 f, v '. a. FPC - CtTSTAL EIVE2 33 FT WIPSS (SIG THETA) MAR 1975 -is ~ O. .{. -O .m SUMPED OVIP ALL STABILITIES' EIND SPEED VERSUS DIFECTIch (1H NUNPER 07 CSS.) g. WIHC HI t.0 SPEED (wPH) AT 10 HETER ' LEVEL DIEECTION 3 4-7 a-12' 13-18 19-24 >24 TCTAL kHE 4 11 21 0 0 3 76 m hE 4 12 35 3 L C 54 E!JE 5 7 25 2 C J 39 E O-18 . 3i 2 3 3 SC g. ESE-2- 16 14 0 0 0 32 SE 2 2J 17 0 0 C 39 SSE 3 9 7 6 0 3 22 g S S 9 9 16 5 G 19 -SSW 1 3 26 35 4 'O 68 SW G 6 25 13 1 0 45 E!w 2 7 14 2 0 s
- 25
<~ ~ W 1 13 21 12 0 G 47 ht:W 1 13 12 8 1 J 32 kW -O 7 2 4 2 0 15 3 E!!W 1 7 6 1 0 0 15 A 2 19 14 1 0 0 36 O.. T Tat 24 174 27a its 13 0 594 0. Peel os cr cALn inn or HOURS) a -MISSING DATA (NO. OF HOURS) 15C O 'O O O O ~ O Q O ~ 10
I.... ' O '- FPC .C:tfSTAL.EIVEC 33 F T WINDS (SIG THE TA) MAP iSTS 1T j. ST titLIT Y CL AT.S A bI AC SPEED VERSUS DIRECTION tit. t, UMBER GF CBS.) 1D. 1 -- WI t:0 ' WING SPEED (MPH) AT 10 MITEit. L EV EL .O DI6ECrI0t 1-3 4-7 a 13-1s 19-24 >2 5 TcTAL hNE O-1 1 0 0 0 2 t;E 3 1 1 0 0 0 2 4HE 1' 0 C 0 J 1 (3 E C L C C b 1 C-0 0 0 ESE e C = SE O O C 0 C 0 G '3' SSE 0 0 G G G C 3 3 C .L e 0 3 SSW 0 e e e a o r O SH .0 0 0 0 0 0 0 WSW 3 <J 0 0 C 0 C W C G C D G 0 1
- q.
kNW 0 1 C C 0 i e hw _C 4 C C 0 0 0 8' 8 8 8 8 8 8 l' O P4 J 0 0 0 4 3 0 '8 T O T A t. 1 3 2 0 0 0 E- !O PERICDS OF CALM' (NO. O F HOU'tS) 0 iO i{g WIND SPEED VEP. SUS DIRECTION IIll NUMBER OF CSS. ) ST A3ILITY CL ASS B 4 4O WItO WI h3 SP E ED (MPHI AT 1C HETER LEVEL DICECTIch 1-3 4-7 8-12 13-18 19-24 >24 TCTAL ta:E 1 0 1 0 0 G 2 kC .st a a 3 0 e c 3 ENE 1 0 1 0 0 0 2 i-E 3 1 1 C 4 0 2 .O ESE C i 3 0 0 0 4 SE 3 1 1 0 0 0 2 SSE 3 G L C C G 0
- O S
3 e e c e a e SSW D c c 0 a 0 e SW 0 0 0 0 0 0 C SSW D 0 c 0 C C t l0 W 1 0 0 0 0 0 C G 0 W?!W D C C 0 hw 0 0 0 0 0 0 0 3 M*:W 0 9 C 1 C u 1 k C 2 0 0 3 C 2 T Tat 2 s 1c i c 0 la O 6 f PERICDS CF CALM (PO. OF HOURS) - C g O e., %e*
3 2 y L L A A T 1 T f C T5539u412r3733C021 T465701843774A4283 1 2 R 171211 132 121 4 2 ) ) S 4 S 4 a 2 B 2 C >CG033a00C0000G000 C >0C000000000C0000t F c F C e R s 4 E 4 e 2 E 2 L - M L - v E9 U E9 V 10 0 0 4 e c C 0 :. 0 0 0 3 C C 3 0 N V1000000b2408010207 5 E E 7 n L N L 9 I I 1 ( R ( R E R s T 4 E h T8 A o E1 O E1 M i M-I M - T 3 T 3 ) c
- 10S02ec00C0010G314 C
010300eC27041150003 A s 1 E 1 2 1 5 T Cn oR E I I H a T T A' D T 3s A sS G
- t
) 2 SU I 2 I As H1 C AS H1 S Le P - LR P - C ( Cc M82A2643C1c3462:C12 cE M82836384b79C561131 v ( 1 5 V ( 1111 i S Y V - 2 D To 3 1 E Ir E' TD D IE E I Lr E ) tE E W Io P I S lP P Gs S 4 aS S - S T A 1 R U e A 7 F T9 C417C1 U C v T0 D-O is t1112C261CC* 1 H e sk II 42?C672202457530S2 H t 3 t I 2 e I I 3 w W 5 F e W W F ~ O J O E V O I o N M 3 N ( 3 ( L 1201Oa0300D103O804 ( 1O32OD1C0CD111C1GC M A T L 1 L A S A C y C RC F e N C O N O S O I S L D I C OT'. A C DT L O P NCE' E t - E w W W .W T I NCE E E E W ! wW C R A C W W T I F dli ". E X I. sES sW$ W '; ~ O R IENEN sES SW ? INT E hEEEsSSSShWWk"NT D' P . WEANEEES!5SS*WWt 1I i t E I P D ~ e g, O
- g...
g O O
- s*
O . C O.O O g O*g O g 3, g 't. s a ) E .b a t' ' h't i;U !il* t' .1 ~ i- ' .li - g1 8!! g I :i!il;j,
- lt!
l 1 2 L L a A A ~ T T
- (
C T27e,627203518f0025 T 12.2 3 2 213 2 0 C C C 1218 1 s1121232 i 1222 1 2 ) ) ~ S 4 S 4 ~ 6 2 B 2 0 >G5OJ00003008G380G C > 080000D0C03CGsJ00 F f C O C R 2 4 E 4 C 2 E 2 N L - M L-U ?9 U E9 c N v1E2aJS vJ3C1 a8G28ce N V10#000G03J033J0J0u 5 E E 7 N L N L 9 I I 1 ( n ( R E E R h T8 k T8 A O E1 O E1 N I M - I H-T 3 T 3 ) C G1Ce20Ce483918338O3 C 31080000C1200061014 C. E 1 1 4 E 1 T Ts FE e E I I H D T D T T A A SS SS G St ) 2 SL i2 l I AS H1 C AS h1 C S L - c - LR P-t ( CE M 85597 453293C841S* 2 CE M808CsCCC100CCCe001 V ( 11 19 V ( S Y Y y G TD D TD D IE E IE E I L t E ) LE E W IP P S IP P S ) 0S S M 9S S R T a T O A 7 U F TD C* O Tc D,4132O12110DG0LC211 O SN A
- f. o2"97457120834S10 H
Sh t H 3 I I 1 18 I I 1 3 W W F W W r O c FE ~ t' O 0 I N ~ 4 '4 1 t ( 3 ( L 11 a 8 C 110 O 0 0 C 8 3 0 S i 4 M 1O1C;1OO3DDGcDc0O2 r ~ A L t T A A S C c T "t F r C O c N N e. O S O s I L C I t o C aT ~ A O DT s c P t CE E E E L W W T I NCE E E E W W W W i I F Ii1 E" SES SWS J d " C R IEtl EM SES SWS 2 o R Kn1 AEEESSSSSb'Ki"kT E WEA*EEESS5SSWWuSPNWN.NT E I P I D D ~ ~ ~ e g g n" O
- 6*
^ 0 O O O g O*O O g g O O O C.. *b. 1 1.l ? 7 -l
- l
[ [ ,3 l
- l
?!*,j6[ 6 ii
N N e e o e e e I i 8 I 4 .J 4 l U I p= to t a edet C o t'seOs/C.*EJLtC U et M k e 1 I e M' 4 m N O-A o r3 a si e o o CJ e o n u o o u e a I, w a Ut t N e L .J 9 I D su o' j E D ** ** *14 6 *T O *18J U O F5 3 PJ **3 O *1 C3 C9 M kJ j 3* .J CD s.4 tI we
- g*
tQ - ft i 4 6
- r O
h3 +4 l E M 3* 0 >= M a U 49e4 O r3 y c.s O F3 o Q rJ c su u fl3 O Q tJ Q 4 b6 ~ +4 >= 02 y w .4 Z O t= W Li M M3 N es 4M 1 ee u M .J M O $ Ug g e p u u u p u o J u u ts u v o c o u M' O >O O 8 a ** w taJ M' .J nd bJ . 3-H 4a ' IL M Cd.tra M fr ., t= A D h. 8=g O$ O I b1 e. 2 & O C3 e4 e4 O O J 3 43 U O O tS e E4 O N Z M M. M 'M 3 3 e-4- ' <t LJ I e 0 l M-2 (f 1 M. w t .J - ' ee O O (3 C9 La r3 u "9 O O O tt t3 O r3 v4 et E-f 4 -e= ~ q M e U W U. U. O t s 2 e o' M H^ aJ O 'U. Mh et U h 3 U tea t.8 . he - he 3 2
- E 3
>= -H. M2M t l b M k,J 3* to4 7..M. te.' Mv M M. M 2 2 a a = =,O ft, Z 2 ;* 1 i 2 aa o a. O l l 1 OL 0 9. O -: O 'O. - ' O - - O O O O O O O Oe 0 0 O O'O O .Ol i -...~.........,.,...........
- 3
- t.
.O 24 HOU51 $UwM2 5 f CF WISO SMErt CISTrITUTISH 35' t i. . FPC - CRYSTAL *IVE R 33 FT WIN 05 (SIG THET A) AF4 1975' -f Q' ' 4 TCT AL NUM3ER CF. %S DINGS 7.:CCILE+S2 .TcTst nus3ca cr REstIncS WITucui Cale.S
- 7. co c cc c+:2 O
- 0-OL WIta SPEED DISTRIBUTION, hO O F 02 5.
O LT.5 .53-3.5 3.51-7.5 T. 51-12. 5 12 51-18.5 18 51-24.: GT-24.0 -D 45 241 323 81 8 2 ..~ O O 'O SUMME0 OVER ALL DIPECTIOkS + WIND SPEED DISTRI0t; TION VERSUS ST AEILITY CL ASS (NO OF 09S.) c. A B C D E F G t 1 0 0 C 0 0 0 f 2 2~ 2 7 25 9 c c 3 7 17 37 118 61 i f g 4 1 21 9G 197 14 0 0 5 0' 3 21 54 3 0 C O 6 a c 4 4 e o c 7 C 0 0 2 C 0 f i O O .;o 1 O . s .. O I, ~ t-O .O = t ! O s.O it g -..... - ~. ~..... _ - - -..,. ~ .~
m I.
- g FPC - CtYST AL EIVE2 33 FT WIkOS (SIG THETA) ASE 1975 ga 9
o ~L. (' 0 eeeeeeeeeeeeeeeeeeeeeeeeese,oeoe.o.eeeee 0: t 'O suanEo cvre Att STAsItITIES ' WI A0 SPEED VL REUS DIRECT 10h (IN NUM324 CF CBS.) t 0, EIM9 .OI3ECTICN WIhD SPEED (HPN) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24 >2 4 TCTAL f.%I 1' -10 24 1 C C 16 ' ~r"s NE 6 a 34 1 C C-49 EME 4 22 16 1 0 0 43 F 5' 36 15 7 C. 0 63
- ~
j g -ESE E 15 7 G J 28 SE. 1 is 3 5 3 L 27 .SSE 4 19 13 .2 J O ?S
- - g S
1 9 17 7 3 0 34 SSW 1 5 32 14 G 2 54 -i-SW 2 1G 27 -21 1-0 61 g E3W 2 '13 18 G 0 3 33 i k 3 in 27 3 0 0 51 l kNw 1 14 33 6 6 0 60 g. KW 2 8 18 8 1 G 37 SKW 4 9 11 2 C 0 26 k 2 27 28 3 C C 60 a 45 241 323 81 8 2 7cc O' 10TA e}g PERIODS Or CALP (HO. OF HOURS) t HISSING D ATA (N0e CF HOURS) 20 O 4 e 4
- o I^
.; O t - O e ., O-
- 9 e
C-a = =.. -.=
e. l'g FPC - CRYSTA L. RIVE 8 33 F T WIM)S (SIG TH ET A) APR 1975 '17 L ST A31LITY CL ASS A f'g WIAC SPEED VERSUS DIPICTION (IN NU'tBZR OF CSS.) !l W
- t!C WIhD SPEED (PPH) AT 10 HETER LEVEL i O' DIEICTION 1-3 4-7 8-12 13-18 19-24
>2 4 TOTAL 'nt E C G t 0 L C C l NE D 1 C c 0-0 1 [O. E C 2 0 0 C G 2 'E"E 3 0 3 j ISE C L 0 C 0 0 C j Q SE 2 C C 0 0 3 0 SSE D 1 0-O d C 1 i S 1 0 0 0 G 3 1 lO SSW-c 0 C 0 c 0 e i SW G 1 0 0 O 1 8 iSW 1 0 0 0 G J 1 l0 8 1 8 8 0 8 1 us:W C D G 0 G I r4W t 3 C C L s 0 ; d 3 8 C 0 3 8 8 0 h 1 1 1 0 3 0 2 TOTAL 2 7 1 0 G G 10 0 i } PERIOUS CF CALM (NO. OF HOURS) - F G O ST AeILITT CL ASS n p WIkC SPEED VERSUS DIRECTION (IN NUMBER CF OSS.) WIND WIND SPEED (PPH) AT 10 HETER L EV EL O DIRECTION 1 4-7 8-12 13-18 19-24 >24 TCTAL htJE O O 3 0 0 0 3 j-O kE 1 2 1 1 3 8 5 E tJE O O 1 0 0 0 1 ..j E D 0 1 0 J J 1 ESE O C 8 O i EE O O O O G G 0 SSE O O 6 C G S C S a 0 0 0 e a c to f SSW G 1 0 0 C d 1 l SW D 0 0 0 0 0 0 .l 3 kSW D 4 i C G J W 1 7 8 1 0 0 17 -l 4 tJW D 1 4 1 0 3 6 ? AW 2 0 C' O 3 0 0 ? NNW 0 0 0 0 J 0 0 { N 0 2 2 0 0 a 4 TOTAL 2 17 21 3 3 0 43 { g e 0 o PERICOS OF CALP (No. OF HOURS) 1i o .i.6 IIO . _ _.. _. = L
1 4 FPC - C'VSTAL IIVEP *33 F T WINDS (SIG THETA) APR 1975- ,10 4 l. ' ST 491 LIT Y CL AST C y WIhD 3aEED VFRSUS DIRECT 10h (IR nuhe:R CF CB S. ) WI ?!D WIND SPEED (MPhi AT 10 METER LEVEL ~)- DI4ECTICN 1-3 4-7 d-12 13-18 19-24 >24 TCTAL hilE O O 5 i C 3 6 AE 3 3 1C C 3 0 16 .3 'INE O 3 4 1 0- ? S ~ E 3 2 4 3 J G 9 ESE 0 1 1 0 0 0 2
- j -
SE - C 1 C 4 4 5 5 SSE J 2 2 C 3 3 4 S. 0 5 3 C 0 C .8 ) SSW J L C C 0 0 0 SW C 3 9 5 1 0 18 FSW G 3 11 C C C 14 s W-2 9 19 2 0 3 32 1 5 19 5 3 C 33 ht;W NW 0 0 1 0 0 0 1 f.N W 3 C C D 0 G ~. N 1 C 2 0 0 3 3 TOTAL 7 37 96 21 4 159 ).- PERICDS OF CALM (NO. OF HOURS) C ) ee eee ee e ee eeeeeeeee eeee ee e e ee e,*eee e eee e ST ABILITY CL ASS D WINC SPEE0 VE RSUS DIkECTION (IN NUH8dR CF *CB S. ) bit!3 WIAC SPEED (PPH) AT 1C HETER LEVEL ) DI:~CTION 1-3 4-7 8-12 13-13 19-24 >24 TOTAL kHE D 9. 15 0 0 0 24 kt 2 2 22 0 3 0 26 ) EnE 4 8 11 0 0 0 23 E 4 18 9 4 J 0 35 ESE 5 9 6 C J C 2C ) SE 1 10 3 1 3 G 15 SSE ? 13 1C 2 4 0 28 S C 3 14 7 3 0 24 ) SSW i 3 31 14 C 2 51 SH 2 6 18 15 G C 41 ) WSW i 6 6 C s 0 13 h
- C 1
0 0 0 0 1 hNW C 8 it C 3 J 21 3 NW C 3 14 7 1 0 23 hNW 2 5 9 2 0 G 18 b c 14 19 2 J G 35 ) . TOTAL 25 118 197 54 4 2 403 PERICDS CF C4LM (HO. OF HOURS) - G )
0 1 L L A A T T c O T31?6Er5121CCC1867 TC8iC0CCC00CC38CC1 11 1 15 ) ) S e S 4 O z B 2 C >0J300C30O0C0000C0 C 2J83C003000CJ080C8 F F O O 1 R E 4 E 4 2 2 B 2 t ? L - M L - U E9 U E9 E V20 0CSoJG?00000000 N V10':0004J30GC08C3J 5 E E 7 H L N L 9 I 1 ( R ( R E E R k Ta A T8 ? c Ei C E1 A I N - I H-T 3 T 3 ) C 2100d0GG0CC1G0C1013 C C108c00000030C08OG8 A E 1 E 1 T F? FR E I I H D T D T T A A SS SS G SU ) 2 SU ) 2 3 AS H1 C AS H1 3 S LA P - LR P - ( CE
- a11e1Gc1 10G0C3264 CE H8C8L00CCCC0GC58GG8 V
p 1 V ( S Y Y TD D TD D ) t IE E IE E I LE E LE E ) ) W IC P S IP P S CS S R BS S' R T A r U A 7 U F T D. 0-O TD o-O St t 51Ce45r311C: 0C5401 H Sk
- 4081C0O: 6c0:C08GC1 H
I 3 I I l1 16 I I 3 W W F W W F R. O O E V 0 O I N N E . 3 ( 3 ( 1 11fC11O103G3C32219 M 103333 OOJcGa 138333 't A L L T A A S C C Y 3 F F C C O N N o S O S I L O I O C 3T A C oT A C F J cE E E E .W W W W T I aCZ E F IE! E! SES SWS
- WN O
R iENEt! E E. W W W W T I SES StS t dM 8 R EsAI E E E S S S S S W W 'A F N h T E w9kkEEESSSSSwWhhEN1 E .I P I P .D D W geII g O. O O .g . 'g m*
- O O
- 3.. O*O g
O 0*O O g O. ! j'
~ l i, t .,~ t i l l l I .a [- O i
- = r.o u o o u o en a ao u u o u o n a a i
a' I .a t, e ~ O A o 5e o r9 o ta r.e #3 cs O *3 CD O ta u o o t b i w l'e. a.' N s.U k6 @ 2 ~ z =,, e4 *S. J o e 2 es e s**c3 3o o e.3e3 u o o l c' n e4
- .w I
kJ. a-O, 'r.,.e O aa o ~ f l Pt o n.< u o o n u o.3 m o n ca a ss am a a cs .=E. 8 W g4 i oa l W w l Z C. t= e-et o M. bi .~ M et M .Z e.4 La m aw i' ** -Og E se ena u G t,s u o u o u u o e u u na u o 'm i n -O e. H A.. sna. ao u 3 M& (L = m DM' M w e= eg D k >* W: O9 Q PN 4 J E1=.3 & Q ree.a u u ei u saf3.349C1 u O 2. M N H r' M 2 J 7 k a: C u "P M. O Z tv P,t me J. L e ca u to a;e u te o u s. eJ es e s a u u ca 3* i t= l, m.
- t o
X l '6 I O M El M O O to g o l II. L' O 'W tiJ -. ta a.., W - 2 3 .2-2 t= H s x a w w,m.a m. m.m. r.e. .e 4 41 = .a - t' .~ x r xu a nv H. D. e J h. + i 9 ~ : O ' ' 0 i. 0 ~ 0-0 ' o. O .'c. o .o c.O o o:o .o , o
- o, o o
0 !, t'
a' .Ql 2fe HOUP SUMMA 5Y Or WIhD SPEED DISTPISUTION 15 0-F 8C. -. C RY S T Ai. PI VIER 33 FT WINCS (SIG THET A) MAY 1975 ..s. O' -TOTAL taum ER CF READIrlGS 7.3COCOE*32 O .TCT AL NUM-3ER CF-REACINGS WITHOUT CA L *S ' 7. 265 3G E* 0 2 O O ..+e WItD SPEED DISTA.IRUTION, ho 0F CBS. O LT.5 .53-3.5 3 51-7 5 7 51-12.5 12.51-18 5 18.51-24.0 GT 24.? 4 70 32C 300 35 1 0 0 t) O SUMr.E0 CVER ALL DIF.ECTIONS FIND SPEED DISTRIBUTION VERSUS STABILITY CLASS (NO OF CBS.) O A B C D E F G 1 0 C C 0 4 0 0 2 8 3 8 30 19 2 O O 3 13 22 7' 1"2 6' 3 4 0 45 1 29 110 6 0 0 5 0 1 14 20 0 0 G O s c c c 1 0 e c 7 9 0 0 0 3 0 0 O .. O . O i e 5 !O i
- O f
l0 l O 'ti C .... ~.
4
- -e
- 16.
_ Q FPC. - CRYST A L '1IVER 1 33 FT WINOS (SIG THETA) HAY 1975 , :- 3,. a j, O 5 sunvEo Ovrp Alt STAllitITIES i O WIND SPEC 0 VuGSUS DIPEC TION (IN NUMDER CF,09 5. ) ' Q' '4!ND EI h3 - SPEED ' (t*PH3 AT tt HETER LEVEL DIGECTION 1-1 4-7 .8-12 13-18. 19-24 >24 TCTAL -{ hME 5 a 2 3 C. G 15 .NE' 11 1; 7 c' 3 C 28 {.0 ) ENE 7 29 19. 0 0 0 5'i E IS 66. 11 1 0 0 76. '.3 ESE 9 33 5 G 0 C 47 SE 4 62 18 1. 0 0 a5 't SE 1 '13 14 1 0 0 26 iO 5 0 -7 is 3 0 0 21 ~SSW 2 8 14 3 C 0 27 '*0-SW 1 5 23 13 1 0 46 'S" 8 1' 3" 7 3 8 62 .O b 1 35 73 2 0 0 111 ( bMW 1 12 ?4 2 d 0 49 NW i 7 21 2 C 0 31
- g NNW i
ic 5 C 0 0 16 h 8 it 5 0 0 0 31 Totat 70 32n 300 35 i C 726 O .i .4 PE:t1 DS OF CALM (NO. OF HCURS) - O 14 n' 8* ' MISSING DATA (ND. OF HOURS) !o }O-C ~! O 1 5 !O e i !O lO 4 eiO , j .i, o
3 I.,*. + . ',ycra - FPC - ' C8t YSTAL EIVER. 3 3 FT WI h0S ; (SIG THET A). N AY 197 5 1F. jl,.' OTA")ILITY CLASS .~ A WIkD. SPEED VE* SUS DIRECTIch (IN NUMEER OF 01S.) O. '.t J bit!3 WIAC SPEE9 (H 4) AT ' 10 H~TE4 LcVEL 'gt' DIGECTION 1-l' 4-7 8-12 13 19-24 >2 4 TCTAL '.- f p*, brie. '1 2' O C. s 0 1 NE -1 1 0 C 3 C 2 J. g .ENE 2 C 0 0 0 0 2 .j' 'E 0-1 0 0 J b 1 ESE lC' C .c 0 0 C . SE - 2 C c 0 - a c 2 } ;.E O SSE C 3 'C C G 0 0 'S' O 1 0 0 J 3 1 cg. SSW-G C- -C 'C C 0 0 ] *g -SW G -2 C D 3 0 2 de WSW w 1 -C 0 C J 1 8 3 8 8 8 '8 3 . O' WNW G C 't 0 0 0 0 WW C 1 0 0 0 C 1
- g t,tt W
'0 C 0 0 0-0 C 3-h 2 0 C C 3 0 2 l. TOTAC S 10-C 0 0 0 18 DO l PERICDS OF CALM (Nn. OF HCURS) C [O j ese 'g ST ARILITY CL ASS .P ~ CBS.) WIkD SPEED VERSUS DIRECTION (IN NUMBER 0F 1 0-WIND WINO SPEED - (HPP) AT -10 METER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 >2 4 TCTAL l NME 1 0 0 0 0 0 1 g hE 0 0 0 0 0 0 C E f;E S 1 L 0 0 C 1 E O 1 1 0 C G 2 $0 ESE C C .1 0 0 0 1 SE O 2 C 0 0 3 2
- e SSE O
C C C G 0 0 -l O S c 1 C 0 s 0 1 SSW 1 1 1 C D C 3 SW D 1 0 0 0 0 1 WSW a 6 9 C 0 a is ? O W 0 6 31 0 0 3 37 .I WNW G 1 2 1 0 0 4 O 8 C C 8 8 8 8 I Nr:W 0 0 0 0 0 0 0 i h 1 2 C C 0 0 3 i TOT 8' 3 22 45 1 8 8 71 !..O } O PERIODS OF CALP (HO. OF HOURS) - C I s I!o
- ;i 'O
'. - - - - - _ n. _ -..~,.n. ---n
FPC - CtYST A L EIv!# 33 F T WI t'DS ( SIG THE T Al N AY 1975 is d-ST A:3ILIT Y CL ASS C h.O, win-) spct0 vrnsuS DIFEcrzon (Is NuuecR cF cDS.) f4 WIMC WIN 3 SPEED (NDH) 4T* It HETER LEVEL + ' g .. DI 4 2C T IO N 1-3 4-7 8-12 13-18. 19-24 >24 TCTAL ht:E D 1 C C C 0 1 4 bE 1 3 3 C 0 C 7 EnE O 2 2 3 S 0 4 , g g' E 1 5 4 i G D 11 'l ESE O 2 1 0 0 0 3
- Q SE D
6 4 0 0 0 it 5E 1-2 4 J C 7 C 9 3 6 1 3 0 t-SSW 0 4' 2 1 0 0 7
- g SW 0
4 11 3 0 0 18 'I hSW D 8 28 6 3 G
- t. 2 i
'I ' O 1 23 '2 2 3 8 68 WNW 1 S 25 0 3 G 34
- t. W 0
1 7 0 0 0 8 k " 1 1 8 8 3 8 2 O N 2 1 C. 3 0 0 3 I.s TOTAL 8 74 -139 14 0 0 235 1.O t .j. PERIODS OF CALM.(NO. OF HOURS) G O l
- g ST ADILITY CL ASS D
WIND SPEED VERSUS DIRECTIOh (IN HUMBER '0F 005 3 sIno WIko SPEED (MPH) AT '1C METLR LEVEL
- O DIRECTION 1-3 4-7 8-12 13-18 19-24
>24 TOTAL 0 3 E 9 hHE i 6 2 l;O >E 9 6 3 0 J c ts ENE 1 11 12 0 0 0 24 E 7 25 6 0 0 0 38 I O ESE E 17 3 0 0 G 26 SE 35 14 1 0 3 50 SSE 3 7 16 1 0 0 in O S o 2 s 2 0 0 9 1 SSW i 3 11 2 G 0 17 SW i 1 12 10 1 0 25 ! O hSW .2 1 1 0 0 4 W 0 3 0 0 0 0 3 Wuw a 3 7 1 0 0 11 i g Ha 1 3 14 2 0 0 20 NNW C 7 5 0 3 0 12 k 3 11 5 C 3 0 19 i . O
- 0TAL za 142 110 20 1
c scs O PERIODS OF CALP (NO. OF HOUC!S) 0 6
- o I
) i j - .m, --.m.,- w-
J t O. rec - ctysrat arvEn 33 rT. WINOS (sic TerTA: MAv 1975 19 ' l' ST ACILITY CL ASS F + - g wit.D JOECD VU SUS DIPEC TI0h (IN NUH3ER CF CSS.) (* - - win 3 WI ND SPEED '(MPH. af 10 METLR LEVEL g DIRECTION 1-3 4-7 P-12 13-18 19-24 >24 TCTAL kNE-2. 1 0 0 J 0 3
- NF O'
0 '1-C 3 3 -1 g-EtE 3 15 t C 0 3 23 E is 12 f 0 c 0 ?? ESE 2 14 -C 0 0 0 16 O '!E F 18 0 0 8' 0 20 ~ SSE 0 1 C D C J 1 S. O C C 6 G .O SSu e 4-t c c C SW 0 0' 0 0 0 0 KSW 0 0-C 0 0 0 G 2 -O k a 0 C C D 0 G WNW 3 C C C C C kW 0 2 0 C 0 0 2 g ANW D 2 C 0 0 0 2 A G 4 ( 0 0 0 4 TOTAL 15 69. 6 3 3 0 94 O PERIODS OF CALM (NO. OF HOUPS) - 4 O' ~ O ST ABILITY CL ASS F WIN 3 SPEED VE RSUS DIRECTION (IH NUNDER OF C3S.) g, . WIND WIAC SPEED (ttPHI AT 10 METER LEVEL DIAECTION 1-3 4-7 8-12 13-18 19-24 324 'TCTAL NME O O G 0 0 3 0 g hE C C C 0 0 0 E!!E 1 C C C d 0 1 E 2 C C G 0 2 LSC i 0 01 0 0 0 1 SI C 1 C C 0 0 1 SSE G 0 .0 0 G G 0 0 S 3 o L e o o 0 SSW C S G C G 0 0 SW -0 0 0 0 0 0 C -s NSW 0 C C 0 0 0 W C 0 C 0 3 0 0 FP:W C C C D 0 0 C 8 8 8 8 8 8 8 O NNW 0 0 0 0 0 0 C N 2 C C 0 0 0 0 O T TA' 2 3 C 0 0 C 5 PERIOCS CF CALM (NO. OF HOURS).- 'C g Q d i 10
f a r..x r a 9 ( e O ' N e e W - D 0 h 9 9 4 mJ ag >= 0 >= ce o o u ta u re u o u o u o s3 o C3 es. M O M 'J 03 N O A c p C3 u*3r2enu osa'.3c3 o c3 o 43 u e . asa J (IJ N 7. .J B 3 W *J' E. > et.2 m o e s u a e s es c% s3 *3 0 es es a es es ist . Z. Lad he - .J ' p M v4 w fE tos 4 >= @ et - O bf e4 .,4 'H E O >= n e Q u e4 O O O O O r3 O O u ts O O u O O O O .~ nn trJ
- e
>* OG - W M i i O > = - -y'. l >= 4 MM Q M3 N po - gM. =I w te M .J (L - IL 1 w UU E C e4.J O e a tJ G o e hp O he O 63 he Q u O w M-k. t -l o - o e -M ww -w 1 l ' -., w. m 3 MO' EL M I . FM M O' > = ~ as - h. 3 g k HQ ' U8 O o . M.* 4 4 u c3. p u J c:, ta c3 r3 u o o u o es es ca I [ - M =M M-j m 2 .s -
- h. '
t a O f, Lee e C H 2 ty m w $'~ l J
- #9 r2 o r* ca em es o o o u o e o o o cs E,
4 .et ' b. - M U k <W g ts t .U O _E t 3 .o M. i H .J c: i O O >= . W -M-2 ' 3-3 2 >= H et O 2 O ba - hJ .M iss ia n2M 2:.t
- o na
- Q , g w e.e = s.J.:
- g it 4 g tas W tes ha v. M vs M.s e a ".z r. >
w p,e - g.. Q 4 w at 4 4 .. n... n. n m- .n- .p. -n..n-
- . a.n n.
. n. n n a n . n. o., e t J f.. n n n.
( }} 2E 'H Cut SUFMAE Y CF WI t.0 SP EED DIST RInUTION 15- ')
- .FPO - CRTSTAL PIVER 33 FT WINCS (SIG THET A) JUNE 1975 TCTAL;NUM3ER CF REA9INGS 7.170 03 E + C2 -
) TCTALl NUM3ER OF QEACINGS WITHOUT CA L NS 7.17000E+C2 L WIh3 S*EED DISTRIBUTION, k0 0F CBS. LT.5 .53-3.5 3.51-7.5,
- 7. 51-12.5 17.51-18.5 18.51-24.0 GT 24 0 0
67 326 393 26 1 0 ) J ') SUMMED OVER ALL OIRECTIoks WIND SPEIO DISTRIBUTION VERSUS ST ABILITY CL ASS.(NO OF 0R51 A B. C D E F G ) 1 O C 0 0 0 0 0 2' 4 6 15 22 18 1 1 3 3 13 29 69 158 53 4 0. 4 ,0 71 145 83 5 0 0 5 0 2 9 7 2 0 0 6. 0 0 0 1 0 0 0 3 7 0 0 0 0 0 0 0 e 3
- ..' s
= I, ~) ~ .4
- a-p..
~fPC - CRYSTT.L-RIVER 33 '7T wit:0S (SIG THETA) JUNE 1975
- 16
).' S'JMPEri OVER ALL.ST A31LITIES ) WINC SPEED VERSUS DIRECTION (Ik NUPBER CF 005.) g-WIH3 SPEED (HDH) AT 10 METER LEVEL WINC DIEECTION 1-I 4-7. 8-12 13-18 19-24 .>24 TCTAL' ME: 6. 19 4 1 0 0 30 . t.F. - 5 17 17 1-3 J-41 c. E *:E - -5 '32 25 1' 0 63 E it 63 .11 1 1 91 p) - ESE 18 32 it 0 0 0 60 SE 5 50 7 1 0 G 63 SSE" 0 12 4 0 0 0 16 S. 1 5 .4 1 0 .0 11 g}' 1 11 11 1 1 G 25 ' E S e: '8: SW 0 9-21 1 0 0 31 g. hSW .1 iL 23 0 0 0 38 W 2 2n 95 5 0 0 130 WMW: 1 if 53 1 0 L 7C kW 4 b 11 5-0 0 26 g' IWW 3 3 0 0 0 6 k 2 9 4 i G 0 16 TOTAL' 67 326 303 2J 1-0 717 p 0 's PERICDS 0F CALM (HO. OF HOURS) p-MISSI t:G DATA (N0. CF bouRS) 3. b 9. 3 Li 3 20 -. - - - - - -.. ~ ~
1 . rPC -.CerSTAL RIVEP 33 FT WIN 3S (SIG THETAI jut 4E '19 75' 17 g. STAEILITY CLASS -A g bIAC SPEtD VER500 DIPECTION ( It! NU M B ER CF CB S. ) '[ : * * " J WIti') WIkD SPEED (M P H) AT 10 MITE 4 L EV EL j.O DIacCTION .1-3 6-r e-12 13-i a 19-24 >24 TcrAL kHE O 1 0 0 0 0 1 hE ~ 1 1 G S 0 C 2-g EtrE 1 6 0 J 1 i E. O C C 0 J G 0 ESE-0 1 C C 0 0 1
- T SE o
O e 0 a c 0 i O g-SSE O C C 0 0 C 0 { 1 C C 0-J L 1 -..O. SS w - c 1 .c c-0 0 1 SW 0 0 0 0 3 0 0 5 ++i WSW 1 2 C 'O O J 3 I w .c 3 C c 0 0 3 O h::N 0 0 0 C 0 C C t' NW i 2 C C 0 0 3 ANH 0 0 0 0 J 0 0 {O-O i 0 0 0 0 1 N ( TOTAL 4 13 C 0 0 0 17 iO PERIOOS OF CALM (NO. OF HOURS) - 0 L ,3 ST ABILITY CL ASS B WIND SPEED VERSUS DIRECTION (It1 NUMBER OF CBS.) }O WIN 3 WIND SPEED (HoH) AT 10 METER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 .>24 TCTAL j hNE O 2 2 0 0 0 4 0 t:E a 2 2 0 0 C 4 1 ENE 1 1 1 0 0 0 3 i E 2 3 1 0 0 C 6
- 1. g ESE O
O O O O O O l SE 1 0 2 0 J G 3 SSE 1 0 C e 0 0 0 1 O s 9 o L 0 a o c .} ESW D 1 0 0 0 0 1 SW 0 1 0 0 0 0 1 SSW 3 3 t 0 c C 4 O W 2 9 43 2 0 0 56 'I WNW 3 4 15 0 0 0 19 I Ah 0 1 2 0 0 0 3 g MNW 9 .1 0 0 0 0 1 N O 1 1 L c G 2 TOTAL 6 29 70 2 a a 197
- O lg PERIO3S CF CALM (NO. OF HOURS)
C e o . O A
P t-m FPC - CRYSTA L EIVER 33 F T WIN 35 (SIG. THETA) Ju hE 19 75 '18 f' !~ ST A3ILIT Y CL ASS C '*g WIhD SPEED VEPSUS DIRECTIOh (IN NUMfER CF CBS.* I wit 0 SPEED (PPH) AT DIRECTION 1-1 4 8-12 ' 1 HETER LEVEL KING fg 13-13' 19-24 >28 TOTAL 't AME. 3 1 1 1 0 0 6 hE 1 4 6 1 2 3 12 3 ENE 1 5 f. 1 0 0 13 E. 2 11 6 G 0 0 19 ESE - 3 L 2 4 0 0 11 g SE 1 3 1 1 C 6 SSE O 1 1 0 0 0 2 S 0 2 1 0 4 0 3. O '. SSW 0 3 3 0 a 3 6 SW 0 6 11 0 0 0 17 bSW S 5 21 C 0 C P6 k 0 13 50 3 o 0 66 .g 'WNW 3 8 29 0 J 0 37 NW 1 1 6 2 3 0 10 O kNW o 1 1 0 o 0 2-N i 1 0 0 0 0 2 TOTAL 15 69 145 9 0' O 238 O PERICOS CF CALH (N3. OF HCURS) C O ST ArILITY CLASS o O kIhC SPEtD VERSUS DIRECTIOh (IN NUMBER CF'CBS.) WIN WIN SPEED (HPH) AT 10 HETER LEVEL O DIREC TIO N 1-3 4-7 8-12 13-18 19-24 >24 TCTAL
- de kME 2
13 1 0 0 0 16 g NE 3 11 9 0 0 0 23 EME 2 18 15 0 0 0 35-E 4 32 4 1 0 0 41 ESE 6 16 8 0 0 0 30 g SE 2 36 4 0 0 0 42 SSE O 9 3 0 0 0 12 S 0 3 a 1 0 a 7 0 SSW C 4 7 1 1 d 13 SW D 1 10 1 0 0 12 "5" 3 3 1 0 0 8 O W 9 3 2 0 3 0 5 1-- WNW 1 3 9 0 3 0 13 NW 2 1 3 ? O O 8 g NNW G 1 2 0 0 0-3 N 0 4 2 1 C 0 7 TOTAL 22 156 83 7 1 0 271 3 0 PERICOS OF CALM (NO. OF HOUtS) - C .-]
- O
..... _ - -. - ~ ~ _, ..... ~ ... - ~ _ -.
m 4. g.- FPO -- ' tySTAL "IIVEP 33 FT ! WINDS (SIG THET A) JUNE 1975 19 STA9ILITY CLASS > E I O WIxo SPEED VER:;US DIRECTION (IN MUNBER OF CBS.) -4 b!ND WIh0 SPEED (HPH) AT. 10 NETER LEVEL e DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL ENE '1 2 0 0 0 0 3 t:E. .0 C 0 C J. O C r#' ENE '1 7 3 0 0 0 -11 E 7 15' L 0 J G 2? ESE 6 9 C 0 3 0 15 -O. SE 1 11 c a s a 12 '5SE Q 2 e c 0 0 2 'S 0 0' C C J 0 C O '53" 1 2 1 8 'J '~ 0 SW D 1 -C 0 J 1 WS2 0 1 C 0 0 0 1 b-0 0 0 0 0 0 '0 g 'kMW 0 C C i 3 G 1 NW 3 1 C 1 0 0 2 C 0 C 8 O A f 2 1 0 3 0 4 TOTAL 18' 53 5 2 C 0 78 O -- PERICDS CF CALH (HO. OF HOURS) C O 5... STADILITY CL ASS O WIND SPEED. VEREUS D;RECTIOh (IN NUMBE~t GF CBS.) WIMO WIND SPEED WPP) AT 10 PETER LEVEL g DIEECTION 1-3 4-7 d-12 13-18 19-24 >24 TOTAL AME O O O O O O O E D C C 8 0 0 O EME G 3 0 0 0 0 0 -E O 2 0 0 0 0 ? ESE 1 2 C 0 0 0 3 g SE D 0 0 0 0 0 0 SSE O 0 C e 6 0 0 0 S o o e 0 3 3 0 SSW D 0 C 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 C 0 0 0 e - O W G C b 0 0 0 0 WNW 0 0 C 0 3 0 0 g bW 0 0 C C 0 0 0 ENW D 0 0 0 0 0 C N O C 0 0 0 0 0 Q TOTAL 1 4 0 0 3 0 5 ..g g PERICDS OF CALM (No. OF HOURS) 0 O 1 O
O j N. 4 e e o e o _J es - > =. O- >= sa ca na we O u 4;t C.a ta p 6e
- .s tJ D r'5 C't 94
=.. M 4 (D N U A v3 (J O n O o *J eJ r3 0.a o O O a3 O O 4. O W W 4 CJ N 1. 2 D .W9 ' 4A E > +4 O O -J CT O 2 63 (J cs O u 3 O O o o 3 N u, 2 .J 9.4 H W sa' . tJ E 4 >= e Di O ks we 7 M E9 M i et o u u o o r3 u o u o t;s o o o ca a o a O o.4 l 4 W - o le g $*4 M-4 O ^ > = l b= - 4 MM i LS MD =N M at M I e4 O -M .a nE (L 6-W te E so a w u ca to 43 o o u o u o aJ O CJ o aJ .> ~ to ' >. O t-Q - D I 2 MW-tas M .J W n.s n. 3 HG E M 83 M M w at m. D O O.D Z 6 *= Q x t O o es o.2..i e s e o 1 O o es t.* O ca o es ' M4 M H n-M - 3 2 A O + 3.. e taa> O M Z tz m .G g .J e4 O C8 O e4 fJ O f3 Ce r1 O >'J 3 ch O O E3 e4 E et ' .J . h-as M O M-(Lo u-2 I O M H J O r .O O >= . ena - 3 2' 3 2 >= M eg O + - (L 2OW ad ' bl te. ~ M tot l'. Les2' to W M M2M 42= O (K 3 fr M d tai W 64 H M M M M.E 3 4 4 4 M >= tal M. A l-O- != j a p ;n-n ~ c, n n: :o' o o. o. o 6 oM r3 o o o'o o o-;o o
~ .y 'O. ~ 24 HO*J< stJPW v 0F 'dIkr SCEED UIST0!c117!ON 19 .lo FPC - CRYSTAL RIVEP '31 FT WINDS (SIG THETA) 1/1/TS-6/3G/75 o' TCT AL NUH1El CF REA0!!!GS 4.10C03E+03 gy TOTAL huMIER OF. REA07t!GS. WITHOUT. CA 6 PS 4.L9603E+G3 C 0 WIhD-SPEED DISTRI6UTICA, h0 CF CBS. LT .5- .50-3.5 3.51-7.5 7.51-12.5 12.51-18.5 1P.51-24.0 GT 24.? 4 315 1967 1718 435 59 2 0 g O SUHFED OVFR ALL DIRECTIOkS wit!D SPEED DISTPI9tTISM VERSUS STADILITY CLASS (NO OF CRS.) A B C D E F G Q 1 G C C 0 4 0 C 2 17 19 47 122. 3) 22 8 3 39 65 259 643 4 49 8C 12 =g. 5 15G 459 704 375 22 0 5 1 7 52 173 192 13 C o S O O 5 21 31 2 0 7 0 C C 2 0 0 C 4 O O O. O O . O O = - - - - - - - - - -
J FPC - CtYSTAL EIVER 33 FT WI ADS (SIG THETA) 1/1/75-6/30/75 22 )~ y. 2 SU.1MED OVER ALL ST ARILITIES )' . hit 4C SPEED VERSUS DIFEC TIch (IH NUMBER OF OB S. ) HIND WIND SPEED (HPH) AT 19 HETER L EVEL g) _ .DIFCCTION 1-1 4-7 0-12 13-18 19-24 >24 TCTAL I,!!E 28 72 83 2 0 0 195 LE 40 9C 179 17 0 0 3P6 () ENE 31 153 146 20 J 0 353 E. ED 220 P3 it' s u 27h ESE-41 128 55 1 0 0 275 () SE 1E 179 77 11 3 J 283 SSE-5 65 54-25 i G 15C S 3 57-c1 78 12 0 241
- )
I Si 124 92 11 2 285 SSW SW 6 52 114 64 3 0 241 hSW 7 78 1C3 13 C 201 () - W 9 141 2 43 26 1 0 420 UNW 8 32 175 27 9 C 3C1 Eh 13 48 76 35 ' 21 0 193 () ?;NW 15 46 38 7 1 0 157 >*os N 23 1C5 77 6 C 0 211 TOTAL 315 1567 1718 435 59 2 4096 () PERICOS CF CALH (H9 OF FOURS) - 4 ) HISSING 3ATA (N0. CF HOURS) - 244 O
- 8 O
O C) O >.ts () () C)
r ..s 1) ' FPC '- ; CRYST;L EIVEP ' 31 'F T WIhDS (SIG THET A) 1/1/75-6/3(/75 21 STA*ILITY CL ASS A hI A0 SPEED VE# SUS DIEECTIch (IN NUFRIR.0F CBS.) ).
- iIt?D WItD SPEED (MPP)'AT ic ?t2Tiel LEVEL DI1ECTION 1-3 4-7 3-12 13-18 19-24
>24 TCTAL N':E 1 3 -1 0 0 0 5 kE. 2 6 i G G 2 9 ') Er3E 3 1 C G J C 4 E' .0 4 0 0 0 C 4 ESE 1 C 0 0 0 1 SE 2 0 L 0 0 0 2 .) SSE-1 1 C G -C 2 5 2 1 1 0 J G 4 .) SSW G 1 0 0 S D 1 SW D 3 0 0 0 0 3 hSW 2 3 C 1 0 0 6 W i 8 C 0 6 0 9 ) W taw 0 1 0 0 0 0 1 kW 2 3 C C J 0 5 f.N W D 1 0 0 0 0 1 '3 N 2' 2 1 C C E TOTAL 17 39 5 1 o o 62 3 PERIDOS. OF CALM (NO. OF HCU5tSI - C O ST A3ILITY CL ASS B -) WIND SPEED VEs? SUS DIRECTION (IN NUMDER OF OSS.) HIND WIb0 SPEED (HFH) AT 10 METER LEVEL g DIFECTION 1-3 4-7 8-12 13-18 19-24 >24 TCTAL N;1E 4 3 6 0 0 0 13 g t:E 1 7 6 i C 0 15 ENE 2 3 4 0 0 0 9 E 2 5 4 G 2 J 11 ESE C 2 5 6 6 0 7 O SE 1 3 3 L 5 7 7 SSE 9 C ( 0 0 0 0 g S 0 1 0 0 0 0 1 SSW 2 3 1 0 J C 6 SW i 2 C C G 0 3 hSW 3 16 12 0 C 6 28 9 E 3 24 83 3 0 0 113 Wr:W i 6 21 2 0 G 3f NW' e i 2 e a 0 3 O hNW G 2 6 1 Q J 3 k 2 7 3 0 0 0 12 TOT'L. 15 85 150 7 0 3 261 A 3 C PEPICOS OF CALP (NO. OF HOURS) g 0
FPC - CR YST A L RIVE # 33 F T W I PO S ( S IG' TH ET A) 1/1/75 6/3S/75 22- -STABILITY LLASS -C 7 WIhD SPEED vavsus DIRECTIOk (IN HUM'CR CF CSS.) d kit:0 wit.C SPEED (NPF) AT 1C METER LEVEL DIRECTION 1-3' 4-7 t-12 13-18 19-24 >24 TCTAL ANE-8 5 9 2 0 0 24 NE e 22 It 1 C 61 y: E P!E 2 -11 16 3 0 v 32 E 4 20 23 6 3 0 53 ESE-5 7 10-1 0 0 23 3 SE 2 12 1C 5 0 0 29 SSE-1 7 7 0 L 15 5 2 12. 12 1 5 C 25 3 SSW 3 10 5 i C 0 16 SW i 14 34 9 1 0 59 WSW 1 P6 66 6 S c. 99 3 W-3 83 14C 9 1 0 23E Wi W 2 23 77 5 3 0 110 .Nd 4 3 15 2 0 0 24 ~3 . f; :W 1 2 1 C 0 0 4 N 5 2 4 1 0 0 12 TOTAL 47' 259 459 52 5 6 82? D. PERIODS OF CALM (NO. OF HOURS) - C D' ?*e g ~ WINC SPEED VEPSUS DIRECTION (IN NUMBER OF CBS.) STABILITY CLASS D p kIhn WIb0 SPEED (M PH) AT 10 METER LEVEL DIEECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL i;!* E 4 39 47 G O G 90 g tE 25 46 89 ^ 8 0 0 iE8 ENE 13 47 67 4 0 0 131 E 21 96 44 5 0 0 iE6 ESE 19 57 24 C J G 100 SE 6 95 45 4 J 0 150 as SSE 3 41 34 7 i C 86 1 22 42 22 2 0 P. 9 SSW 3 16 63 41 S 2 130 SW 6 ?> 64 32 1 C 118 ) kSW 4 32 ?4 5 0 0 65 h 2 ?S 20 14 0 0 61 WNW 2 36 6C 1C 4 0 112 NW .3 13 37 15 8 0 76 ) krtW 5 13 21 3 U 0 42 N 5 4C 33 3 0 0 81 TOTAL 122 643 7G4 173 21 2 1665 PEPICDS OF CALP (NO. OF HCU45) - C e
8'
- ty FPC - CRYST AL RIVEF 73 FT WIrns (SIG THE TA) - 1/1/75-6/30/75 23-ST UlIL IT Y CL ASS E
N - g) wit.D SPEC 0 VCESUS DICICTION (Its FJUMDil CF C35.). WIr:0 WIron SPEED (MP H AT 10 ftETER. L EVEL .). ' DIEECTION ?
- -7 3-12 13-18 19-2*
>2 4 TCTAL hME -9 17-2C 0 0 0 46 tt 1 9 49 7 C .C Et ys ' . Et!C 9 63 r3 13 1 G 177 ^* C El 73' if G 3 0 111-ESE-12 52 16 0-0 0 80 () SE~ 4 63 1P 2. 0 0 47 SSE .1' 14' 12 18 C 0 65 S 0 19 37 49 10 6 111 ' () SSW 3 21 55 47 6 0 137-S *a 0 8 26 23 1 0 SP WSW
- 3 1
1 1 0 C 3 W D 1 C C C 0 1 (3, h tJW i 14 17 10 2 0 46 NW 3 24 18 17 11 0 73 N!!W 4 23 16 3 1 C 47 (-, N 6 47 34 2 6 G 80 TOTAL ' PC 449 3 78 192 31 0 1130 0 PERICSS OF ' CALM (NO. OF HOU43) 4 ED ee ee e eee ee e ee ee ee e e e eee eee e ee ee ee ee e eee e ST ASILITY CL ASS F () WIh0 SPEED VERSUS DIRECTION (IN NUMBER CF 005.) FIND WIhD SPEED (MPH) AT 10 HETER LEVEL () DI4ECTION 1-1 4-7 8-12 13-18 19-24 >24 TOTAL e I hNE 2 5 C C 0 0 7 e 'hE 2 C 4' C 0 C 6 E!!E 3 22 6 0 0 0 31 E 3 18 2 0 0 0 23 ESE 4 9 C G G 0 13 () SE 1 6 1 0 C 0 8 SSE 3 2 C C J G 2 S 0 1 3 6 0 C 10 SSW 3 3 C 3 3 0 3 SW S C C 0 0 0 3 WSW C 0 C 0 C C U () b 0 0 0 0 0 0 0 4 WMW 1 '2 C C 0 C 3 NW i 4 4 1 2 G 12 () kNW 4 4 C 0 C .0 8 h 1 7 2 0 0 0 10 () TOTAL 22 80 22 10 2 0 13E C PERICOS cr CALM ( t'O. OF. HOURS)
- )
- C) t =e eme-gue ame ; emmam *em em sans ogs g eg w ene.agem. M_- _ em ween ea - geon.m. m
J l ; I, i l I l l t t et U >= u og es, @ og u ecs,e CS O u te,4 O N N CJ~. M = N Q A O Ce O O O c '3 O 'J Q &J O es u Q O CJ -kO M tv A tJ r . \\. - CJ N m-- aaJ c,4 O e a.- I'3 3 -N Z so o O r3 es u *3 O ell3 CJ n e a O O O x W 4 ~. 2 m -O \\ Q 14J.4 f e. _~ r, I f. O ~ u.4,1 O 63 c J Q u c u O O O Q O O O g C .a. e c.. m W-H Z' C 4- 'MM Mm _N 'N . es,M,.. J. c.e.. Q M L't.J..I.so o o u 6,u u u ts u cs u tiv *3 O u u M Q >C O E ~.. m M .d le - L+J amm 3 M4 a-E/3 . C ' 61 M EY - 4 3 k 'k U ^O, O - M4
- f. J G ea @ J e.1 O a 3 ye u O es eJ o O e4 o N I
-- M N H et PO ~3 3 k O . CCm Cz 1 EP. 88 9 g ..=J 4 O 4 O N,4 O O O e3 O O O,4 u,1 N ac E, i .M O W k o o 2 g 4 C M H .J Q [ 'O O-4 O k a-z o u,- w w w 3 .2 2 - 'M ad n hs E M las vs M3m n32 -o. N . J (F. d : bA W W M M M 6/1 M 'R 3.6 4 Z 2 544 .M 4 O l rt ;, {. n 'o : o L io o .o o _o o on o-o . o.: o o o o.: o o i
- ncrvm7vn 1.u. .,=.m y p p Q.G. Q 3q'm m.!;y= w w}l - ~ w,r m r w -w -~ ~ m y n - p g.n, ;. eyy .j' :, g:L 'Qft; W pf ; ^ 3 3 p s' _n y? 's g ; ~ 4, ~, .a ~ -.v .A % l?pf ;'.,. : j*p.g. y ;p y;.9 w Qf fx.g - &,3 + ' n:. m' - @; 7 : e g:. M.. M m, - j-g... f wg.. g, cy, :.g. ~,. ..f . y n 7,,3 3 -a ~ 4 2: c I ug.~ go n ., u.py -pa .-~v =- n.e , 5 ;2 .y + w,w ,, y ; eg{,g # - +. g,, M 2,, .,e. u. -A 1 . c, ,o w.. s ~ .f.. y. .n; +. A, v,.- ~. ur Se.- .a .w; m:..g~n j o ,.ny, r. -- ,. w g n ys, w n 7 w ;+ z e c ;.~ g me 4 m
- q
.k 4,. " n.- , a:. ?'(h** - Re + s.fl 9' T. , cfi4W.3e .n M % y c [n V nR$$ g f@ j", s y egd.M.,;:S@W.. QMWA l~ - .E f k f k I$ N W Q k p%&w h hN h k M,. wQ-v& g e g.f.M P f.# M jf.y.h%;w%a'n m.hh -N$W b d f 4 9~ n mW W M J.. ,,Q p y m m. .se y n 2 QW-ageww-my s m m.y vw.y m ra yu yf p dpa &p.phg;e:ykbDsh, p& +%Q&$g&g g )3W52N%y$nyg#%y%n
- &g p$5p a
y g ,e s $ N ;$ M M!j Mrweo w%+y u p$ @y:a> d, W $b @.M.ny M M, W,.y n b,ym.m.. w;3.c: 3 s$m 7.. yw.1s 4 Qy g'%x. y%.-w:g ::q A.y : Q *%-1 -q 4gy p m &y M w w,W p gia.w ywc: m@.g M Wy, A,;y
- .c;-
nwa yv 2., p.., ydqw p., 4 M M yp lQ' ? QLW:y% @da$4 %y%s%y thMW% Qg Q '4ffg W 43y 9fN.,7+ sG ~ Q% 4
- dt^~g M M. % w 4% @r& d?"Mw-
- W 3
%. J. r
- m..n, m&.4, s#e%ww~
at/kb)m%.y L. )#m, s.s."Bu.:q; w,y ~ Win.d$p+ .s. MM irection4enNnh.n e c ttons,of Wind 1 %y. g % ii W ".Distn ~ ww. v w:5p;.wkm&M,W, s.+p ,49.g>tes u 7
- n c,w m.m p z C Ea. :h.& s u
m.w. ~+ pp. m"w.e n,and C.ombin,.edcStaibmty$:Olass.w&q$m wy.w;r:%m,p@< 3:Wh w esi e c hyg~w - m ~ ~ ,ac u
- c. e gg -
.VT, Based on c0, for, th~eR5;~-ft LeveU. m:w., C 7 g M 4 ,q. ,~ ~ y. k h. N.(a'? O b_; =j '.g Q 9 a. g h.p-Q h ? Q-Q +. $ h f $ :. h a ?,/ h. ~c'-& h:[p m.y yan-n 9, ~ I hk i m9%.m..wm nnuhM m e e e m. q W % m a a. w w%Qg % y49 4yL gg gm.a p y QlWW yppyndq~m$ %y' h~ ? & [ ~y.5 kg&p; m r g Qgggf Qg. Q s w M~ k, A %@% ~ i %w-n y: q.a W.f,n n-G .~ N' T) u s ,?., kla l ,.v t ~. S?,
- h S g N.Y n4tf.
9 1 W SO A br i .Q-MA AfMS$$W-A 1%4hd3d M*Ws& &a gn n g&g24gw.W+q:hqM %M.e n ;sywn@ W -k m mawM wM g 3 mw.w s a. 4 p W: -A.p: w.a a: % ye;y: W, %u ;%, -g{n O W y: w'.,y. 'm~ Q,- ;.y* %;i %w n -A m T:d._. a.p.9;s e ~Ac AW M Wl^..'tW (. --A U ~3' - Mv , T;,.- s. + %y. a. y a v. 7- . n ;W&wp az y-.., W w wm v
- 3. A
.,,+W w -:* m n w w, 21 r
- s
. z. % 3. _n. '. N - gb ...* e, f '. As t * ' ' * * .... pa ;s, y w,g: ; q. *,1 ; 4' . :, 5 L \\
- r. +
x; g 2,- a . e. y . A.. re.wl5 er-s s..; k n'-Y:* SI; -, 1 9 4 ~ 'n .y .;; L h f (.V W' p..' ' l - W,e.. p* 4; a y ; -Q@.,$,{, . 'm.,.u., m, g 3av / ,e*) .l ,.c. ' T %.~: a '. t ne - x w. .s g., y .~r, ; u g t J, y cvr q
- . 'g 5 a yde Ai, -
i Ny. f ., ',?n - %.:M
- 7 -. n.p. 3 t
r ; ::x.M.w..,7, m,c @p o s s. W + m y & M.3 .. ' ~ y 4%M:~;4w. As Q, y %Mh:fy;;.k, Wu?.* lMQ.W,Q,6%;M;GW2Ww g. w 3 y t n .z .y 4&m, WS:@ap ~ 2 ~~ Y,,m... : .n. w-m + y M,-.,w-m.. n, w . n e-p w'mc:*N W ih'fYw A..m e. h m o"+ s. $ .n. Y Yk Y ? 'N'I %wW;; w#v4.pwe:-w? w - o s[ g% % s*-,yg ) g yeeF am e jh4yg '" _ Egg ['y?s.w.e%Id j;glg 7;[jygg{gef{C;jjf n sge.-;r-o y e [yg g g a p. p sy g m m&e we .m ern m m M m.mwama a u&_we
g_______._.,_.____r.-------_a m___ --~~m ~~-----v-~~~- -w---- -wam NUS WIND DIFFUSION PROGOAH (WINOVANE) 1 1 FPC - CRYS,T AL RIVER 175 FT WINDS tu h' SE AS3N INCEX 1= HAR, APR, PAY + SE ASON INDEX 2 = JUN,JUL, AUG SE ASO N INCEX 3 = SEP. 0ST, NOV SE ASON INDEX 4 = DE C, J AN, FE B WIND SPEED GROUP DESCRIPTICN GROUP WINDSPEED RA NGE (MPH) 1 LESS THAN 05 I,'l 2 0.50- 3.5 3 3.51 - 7.5 4 7.51-12.5 5 12 51-18 5 6 18 51-24.0 7 >24.0 WIND SPEED GROUP EQUIVALENTS ( MP H) CALM 1-3 S-7 8-12 13-18 18-24 GT 24 M'M LT D.5 0.5-3.5 3.6-7.5 7.6-12.5 12.t-18.5 18.6-24.0 GT 24.0 N' S LT 0.2 0.2-1.5 1 6-3.3 3.4-5 6 57-8.3 8.4-10 9 GT 11 0 g KTS LT D.4 0.4-3.0 3.1 - 6. 5 6 6-10.8 10 9-16.1 16 2-21.3 GT 21.4 STABILITY CL ASSIFIC AT ION INDEX DESCRIPTION 1 E XT RE MEL Y UNSTABLE 2 UNSTABLE 3 SLIGHTLY UNST ABLE 4 NEUTDAL SLIGHTLY STABLE 6 ST ABL E '9 7 EXTREFELY ST ABLE i ~ i a
9 9' O. -2.4 Ju==247 or WIb0 SPEED DISTRIBUTION 16 ~ FPC - CRTSTAL RIVER 175 FT WINOS (SIG THET AI 'JAN 1975 TOTAL NUM1ER OF READINGS 6.75000E+02 TOTAL NUM3ER OF RFADINGS WITHOUT CALMS 6.T3000E*02 NI m SPEED DISTRIBUTION, NO OF 085. LT.5 .50-3.5 3.51-7.5 7.51-12.5 12.51-18.5 18.51-24.0 GT 24.0 2 8 89 288 192 65 31 . l!! SUMMED OVER ALL DIRECTIONS WIND SPEED DISTRIBUTION VERSUS STABILITY CL ASS (NO OF CBS.) A B C D E F G I i 0 0 0 0 2 0 0 2 0 0 1 2 2 2 1 3 2 3 6 19 29 17 11 4 0 2 7 57 117 61 44 .g 5 0 0 0 14 82 48 48 6 0 1 0 3 31 25 5 T 0 0 0 1 7 21 2 O . i.1
------ -- e e
FPC - CRYST AL GIVER 175 FT WINOS (SIG THETAS J AN 19 75 17 e....................................... jg les SUMMEC OVER ALL ST ABILITIES HIko SPEED VERSUS DIP.ECTION (IN NUHBER OF CBS.) WIN 3 WIND SPEED (MPH AT 53 HETER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 524 TOTAL httE O 4 10 6 2 0 22 hE 1 5 34 17 i i 59 .ENE 1 8 42 31 3. D 85 g g E 0 6 12 37 2 0 ST ESE ' 1 5 23 13 0 0 39 SE 0 8 17 in 0-0 43 SSE 1 2 13 9 4 0 29 5 1 4 7 13 27 7 59 SSW 0 6 14 16 8 17 61 SW 1 10 18 2 2 1 34 WSW 2 8 7 0 1 0 18 W 0 9 15 3 1 0 28 WNW 0 3 19 2 1 0 25 kW 0 3 29 6 12 4 54 NttW 0 5 13 6 1 1 26
- Ig, N
O 3 18 13 0 0 34 l TOTAL 8 89 288 192 65 31 673 I PEP.ICOS OF CAL M (NO. OF HOURSS - ,2 HISSI NG DATA (NO. OF HO URS) 69 + i.l.sl e e e-B ~
I h. I I l I-I. o es 1 l t I l-I l I I. I l: I I I l. e 1 I I I l a a at g i* >= t= t o O 3 0= et o weo o o o e o o o o o o o o N >= o N et u e4 e o o o e o ** O +4 o o @ l I I l M J M J l CD N CD N O A eoooooooooooeoeoo O Aeooooooooooooeooo i 1,, b .s O e I-W 2 e W 2 CD N D CD N l E J I E JS D We D W CP l M Z >Wooonococonocoooco e. Z >WoooooooooooWoomed 6 W W I e z s z a M M I w K e 2 W W a. = I, - M E 9 6 M KI r -o z - c. O w O W. s a t= M D to P7 g 4 O PS v4 o p p o o p o o p o a c c o o p o D O M.4 p o c o c o a o o o o p p o p c o >= W M e W M l W 4& CD sd .D z M M t-O t-O l 4 6 4 O MM MM l M MD S MD mN a N. M .M z o. .M z o - su a I su ci s' OW I so c o n c o c o n p o c o p o c c o D UW r aD O N o a c o m o ca c c o o o c cJ N l M w a w a-e I 2 t= 0 0 t e 6= 0 O t g M MW W e MW W 3 .J W W - e .J W W = l M (L CL M E N EL CL M t= CD M M tr e CD M to tr l k W D. D e et >= D eO O I O e >- O O8 O l M MZ 2dWoWoooooooooooooN Z e MZ EdooWo ococcoooWoon I 6. M M M l - og 2 3 6 e 3 3 h. O O l E a W I O O O M O m s t 8 . ** O o o o o o o o o o a o o o o o o E .8
- O o o o o o o o o o o o o o e o o E
et 2 .J a et M O O W k. tL O O O e Z Z M O M t 0 .J O M - .J O M O O >= 4 O O t-4 0 .f GL 2 O to W W W 3 3 3 3 t= M 2OW W W W 3 3 3 3 >= oe ' 6 M W L* W 2 MWM sa 3 M Z3Z O E MWZWZ MWM M2 to 232 O E 3 Cr 4 a W W W M M M M M 3 3 2 4 Z 2 e= W 3 EE Z Z W W W M M M M sts 2 3 2 a z Z > W 'I 16 M (L M O O 1 =, ,i .o,..e.
- r. =.
. =. =.= =2 t...
--e.- --.. a - w. c n e.en en e o mt;> FPC - CtYSTAL RIVER 175 FT WINOS (SIG THETA) JAN 1975 19 ST ADILITY CL ASS C WINO SPEED VERSUS DIRECTION (IN NUMBER OF 095 9 CIND WIkD SPEED (HPH) AT. 53 METER LEVEL g 0ZRECTION 1-3 4-7 8-12 13-16 19-24 >2 4 TOTAL N!?E O O 1 0 0 0 1 NE O O 3 0 0 0 3 ENE O 1 1 0 0 0 2 -2 0 2 0 0 0 0 2 ESE 0 0 1 0 0 0 1 SE 0 0 0 0 0 0 C 9sE O O O O O O O 9 0 1 0 0 0 0 i SSW G i .0 0 0 0 1 SW 0 0 0 0 0. 0 0 h3 W 1 1 1 0 0 0 3 y 0 W 'O 2 0 0 0 0 2 N' WNW G 0 0 0 0 0 0 NW D 0 0 0 0 0 0 NNW G 0 0 0. 0 0 0 N O O G 0 0 0 0 TOTAL 1 8 7 0 0 0 16 0 GERIDOS OF CALM ( N f). OF HOURS) = ST ABILITY CL ASS O ( WIND SPEED VERSUS DIRECTION (IN NUMBER OF CBS.) wit:0 WIND SPEED (M P H1 AT 53 HETER LEVEL DIRECTION 1-3 4-7 6-12 13-18 '19-24 >24 TOTAL hNE O O 2 1 0 'O 3 NE 1 2 17 7 0 1 28 ENE O 2 13 3 1 0 19 E O 2 2 3 1 O 8 ESE O 1 4 0 0 0 5 SE O i 0 0 0 0 1 SSE O O 3 0 0 0 3 by S 0 2 2 0 0 0 4 SSW 0 0 4 0 0 0 4 SW D 4 2 0 0 0 6 WSW 1 2 2 0 1 0 6 W 9 2 2 0 0 0 4 WNW D 1 2 0 0 0 3 kW 0 0 1 0 0 0 1 NNW 0 0 0 0 0 0 0 N 0 0 1 0 0 0 1 TOTAL 2 19 ST 14 3 1 96 !N Nh O PERIODS OF CALM (No. OF HOURS)
_._w i 13 ' FCC - CRYSTAL RIVE 2 175 FT hlNDS (SIG THETA) J AN 1975 20 + ST ABILIT Y CL ASS E WIPO SPEED VERSUS DIRECTION (IN NUMBER OF CBS.) WIND WIh0 SPEED (HPHI AT 53 HETER LEVEL OIKECTION 1-3 4-7 6-12 13-18 19-24 >24 TOTAL NNE O 1 4 5 2 0 12 NE O 3 10 10 1 0 24 ENE O 3 22 16 2 0 43 E D 1 5 9 1 0 16 if ESE 0 2 6 1 0 0 9 l 8 '8 SE O 2 8 6 0 0 16 SSE 1 1 6 4 3 0 15 S 0 0 3 4 9 1 17 SSW D 2 2 7 5 2 to SW 1 3 10 2 1 1 18 WSW 0 4 3 0 0 0 7 W 0 3 10 2 0 0 15 WNW 0 1 13 2 0 0 16 NW D 1 7 4 7 2 21 NNW 0 1 1 3 0 1 6 N O 1 7 7 0 0 15 TOTAL 2 29 117 82 31 7 268 '] PERIOOS OF CALM (NO. OF HOURS) 2 ST ABILITY CL ASS F WIND SPEED VERSUS DIRECTION (IN NUMBER CF 085.8 WINO WIND SPEED (HPH) AT 53 HETER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >24 TOTAL NNE 0 2 1 0 0 0 3 g tJE 0 0 1 0 0 0 1 ENE 1 0 5 8 0 0 14 E O i 3 6 0 0 10 ESE O 1 4 2 0 0 7 SE O 4 5 7 0 0 16 SSE O 1 2 3 1 0 7 5 1 1 2 7 17 6 34 SSW D 1 6 4 0 13 24 SW 0 2 4 0 1 0 7 i WSW 0 1 1 0 0 0 2 W 0 0 2 1 0 0 3 WNW 0 1 2 0 0 0 3 -{y NW G 0 17 2 5 2 26 NNW 0 1 4 2 1 0 8 N 0 1 2 6 0 0 9 TOTAL 2 17 61 48 25 21 174 1 PERI 005 0F CALM (NO. OF HOURS) 0 o e
~. - an O e ,7 t ) ) P
- I.
Il I i I I i 1 I l 1 i I I I I I 1 l 6 O I t= N +8 m v4 @ 4 M J P9 O M P1 m N P.4 N we we v4 v4 v4 - 1 I 1 4 I 8 7.......ONoo.....N I I b i 5 l m N z s. l D WP z l g gwooooooowMoom...om i e z s e e4 - M l W W B Z w 4 3 8e. l .7 o w.4 l ~ z. M l 4 O M M. O J P O. @ N N e c o o n. H o c t-w .4. l W OW z e- >= O t-O MM - Ms N4 i e M 4M z w sM 4 0 g ' o y y G N e4 m N @ 4 N u N N o e4 N 4 m e d, I o > l' 5 :S S i z sw w M CL 0. M i e - em M.- = w < 1 po O 8 O . na z.,oooo.-ooN .No z l O E E w I o I E 1 o z l E M tiP B .l =J weo O O =eeOC9O O O u o a.3o o,g z s l t= 4 M o 1 ae w 1 o o z '. I 9 o M l 1 M .J Q l'1 . n> e o p l (3 zuw w w w 2 z = 2 e-M l a ~wwwr MwM MzM =2r o e ll 3a4EWWWMMMMMXXJ4&Z> W i ~ e. Il 'O !l !I
- i E2 C'
E3 52 . F.2 i n a
~ 15 24 HOUR
SUMMARY
,OF WIND SPEED DISTRIBUTION FPC - C8tv5TAL RIVER 175 FT WINCS (SIG THETAl-FE8 1975 - lN - TOTAL NUM9ER OF 8EADINGS 6.62000E*02 TOT AL NUMBE8t CF READINGS WITH3UT CALMS 6 62000E+02 N HI ND SPEED DISTRIBUTION, NO OF CBS. gg LT.5 .50-3.5 3.51-7.5 T.51-12.5 12.51-18.5 18.91-24.0 GT 24 0 1 18 101 285 186 60 19 SUMMED OVER ALL DIRECTIONS WIND SPEED DISTRIBUTION VERSUS ST ABILITT CL ASS (NO.0F CES.) A B C D E F G 1 0 0 0 1 0 0 0
- l 2
0 3 3 1 2 1 0 3 0 2 11 30 34 10 14 4 1 2 9 28 114 66 45 5 0 0 0 10 82 61 33 6 0 0 1 2 15 32 to T 1 9 1 0 3 11 3 gg D s G q9 4
w. ._ ~__ - - -
~___--___
FfC - C;YSTAL RIVER 175 FT WINOS (SIG TPET A) FE8 1975 16 V -I I SUPPED OVER ALL STABILITIES WIND SPEED VERSUS DIRECTIOk (IN NUMBER OF CBSel WIND WIND SPEEO (MPHI AT 53 HETER LEVEL DICECTION 1-1 4-F 8-12 13-18 19-24 32 4 TOTAL NNE 1 7 8 12 0 0 28 NE 3 6 8 7 0 0 24 EME O 9 36 27 2 0 74 E O 6 26 11 0 0 43 I ESE 1 6 21 9 0 1 38 l SE O 2 20 8 0 0 30 g SSE O 5 9 6 1 0 21 S 0 4 19 10 9 2 44 SSW 1 5 18 35 28 5 92 SW 1 5 8 13 10 1 38 WSW 1 9 12 1 1 2 26 W 0 4 22 2 0 0 28 WNW D 7 28 13 1 7 56 NW 1 13 29 18 T 1 69 NNW i 7 12 5 1 0 26 N O 6 9 9 0 0 24 TOTAL 10 101 285 186 60 19 661 PERIOOS OF CALN 1NO. OF HOURS) 1 10 l HISSING OATA (NO. OF HOURS) 11 B m I 2 [
FPC - C2VSTA1 CIVER 175 FT WINDS (SIG THETC) FEB 1975 17 l' STA9ILITY CLASS A h!NC SPEED VERSUS DIRECTICH (IN NUMBER OF CBS.) CINO WIND SPEED (MPHI AT 53 METER LEVEL DICECTION 1-3 4-1 8-12 ~ 13-18 19-24 >24 TOTAL N?4 E O O O O 0 0 0 NE O O O O O O O ENE O O O O G 0 0 E O O 1 0 0 0 1 ESE O O O O O O O SE O 0 0 0 0 0 0 SSE O O O O 0 0 0 S 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW O O O O O 1 1
- W 0
0 0 0 0 0 0 WNW G 0 0 0 0 0 0 g NW D 0 0 0 0 0 0 MNW D o 0 0 0 0 0 N O O O O 0 0 0 TOTAL 0 0 1 0 0 1 2 0 PERIOOS OF CALP (NO. OF HOURS) j ST ABILITY CL ASS 8 WIND SPEED VERSUS DIRECTION (IN NUMBER OF 095.) WINO WIND SPEED (MPHI AT 53 NETER LEVEL DIRECTIGN 1-3 4-7 0-12 13-10 19-24
- 24 TOTAL NNE O
O O O O O O NE O C 0 0 0 0 0 ENE O O i 0 0 0 1
- g E
O 1 0 0 0 0 1 ESE O O O O O 0 0 SE O O O O 0 0 0 SSE O O O O O O O S 6 0 1 0 0 0 1 SSW 1 0 0 0 0 0 1 SW 1 0 0 0 0 0 1 WSW 1 0 0 0 0 0 1 W 0 0 0 0 0 0 0 WNW G 0 0 0 0 0 0 NW 0 1 0 0 0 0 1 NNW D 0 0 0 0 0 0 i N O O O O O O O TOTAL 3 2 2 0 0 0 7 0 PERIODS OF CALM (NO. OF HOURSS - 0
_~__m~ m_ .I' 1 FPC - CRYSTA L EIVEQ 1F5 FT WIN 05 (SIG THET AI FEB 19 75 10 i i ST ABILITY CL ASS C e WIND SPEED VERSUS DIRECTION (IN NUMBER CF 095 1 15 WIND WIk0 SPEED (MFHI AT 53 METER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 324 TOTAL HNE 8 e 0 0 0 0 0 NE 2 2 1 0 0 0 5 ENE O 1 2 0 0 0 3 E C 1 O O O 0 1 ESE O O 3 0 0 0 3 SE O O 2 0 0 0 2 SSE O 1 0 0 0 0 1 S O 1 0 0 0 0 i SSW 'O O C 0 0 0 0 SW 0 0 0 0 0 0 0 N WSW 0 2 0 0 1 1 4 W 0 1 1 0 0 0 2 WMW G 0 0 0 0 0 0 g NW 1 0 0 0 0 0 1 NMW D 0 0 0 0 0 ,0 N O 2 0 0 0 0 2 TOTAL 3 11 9 0 1 1 25 PERICOS OF Ca(H (Nor OF HOURS) 0 o ee see......eesse...... see........... STABILITY CLA'S D S WIbD SPEED VERSUS DIRECTION (IN NUMBER OF 085.1 HIND WIND SPEED (MPHI AT 53 HETER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >24 TOTAL NNE O 2 1 0 0 0 -3 NE o 3 3 2 0 0 8 ENE O 4 3 0 0 0 7 g E O 2 3 2 0 0 6 ESE O 2 2 1 0 0 5 SE O O 4 3 0 0 7 SSE O C 0 1 0 0 1 S 6 0 0 0 0 0 0 SSW 0 4 0 0 1 0 5 SW G 1 1 0 0 0 2 HSW D 6 3 0 0 0 9 W 0 2 6 0 0 0 8 WNW D 2 0 1 0 0 3 NW 0 0 2 0 1 0 3 NNW 1 1 0 1 0 0 3 N O 1 0 0 0 0 1 TOTAL 1 30 28 10 2 0 71 O
- ERICOS OF CALM (No. OF HOURS) 1
.o
- ~ - - ~---~# FPC - CQYSTA1 EIVED 1T5 FT WIN 05 (SIG THETAI FEB 19T5 11 STAf!ILITY CLASS E WIND SPEED VERSUS DIstECTION iIN NUH8ER OF CBS.) WINO WIhD SPEG) (HPFI AT 53 METER LEVEL DIRECTION 1-3 4-T 8-12 13-18 19-24 524 TCTAL NNE 1 4 5 4 0 0 14 NE O 1 4 5 L 9 10 ENE O 3 23 24 2 0 52 E C 2 9 2 0 0 13 ESE 1 2 4 1 0 0 8 SE O O 2 0 0 0 2 SSE O 1 4 5 1 0 11 S 0 2 11 9 5 0 27 Ssw 0 0 6 9 2 0 17 SW 0 4 1 1 1 0 7 WSW G 1 8 1 0 0 10 W D 1 8 0 0 0 9 'g WNW D 3 12 7 1 3 26 NW G 6 13 4 2 0 30 HNW D 2 0 3 1 0 6 N O 2 4 2 0 0 8 TOTAL 2 34 114 82 15 3 25C PERICOS OF CALP (NO. OF HOURS) O e...eeseeeeeee.coseeseeeeeeeeeeeeeeeee e ST ABILITY CL ASS F WINO SPEED '4ERSUS DIRECTION (IN NUMBER OF 085.) i WING NIND SPEED (MPH) AT 53 HETER LEVEL DIREC TION 1-3 4-T 'a-12 13-18 19-24
- 24 TOTAL N N F.
O i 1 6 0 0 8 NE 1 0 0 0 0 0 1 g Et:t 0 1 5 3 0 0 9 E C C 8 3 0 0 11 E?,E O 2 5 1 0 0 8 TE D 0 3 4 0 0 7 ,S E O 1 4 0 0 0 5 S 0 0 5 1 4 2 12 SSW 8 1 12 18 18 4 53 SW 0 0 6 7 6 0 19 WSW D 0 1 0 0 0 1 W D 0 6 0 0 0 6 e WNW G 0 in 5 0 4 23 NW 0 2 10 9 4 1 26 NNW G 1 4 1 0 0 6 N 'O 1 7 3 0 0 6 TOTAL 1 10 66 61 32 11 201 h PERIODS OF CALM (NO. OF HOURSI 0 I a
O o N ) ) ) 3 I 4> Q 3 > M e N o,4 v4 e4J N M P3 eD O' s M 4 e ** >= M ) og we o I 1 M d [ O oppoWoooWWoooooom I b aW 4 N = W j g z g-oooooooo~Moooooog e x l we M I w w W W X r* e k O taa v4 M EO >= M 4 O M e4 N O o M iD +4 e o o M o N o e o 4 P1 W M M ha LS EK Z M ee O I o M M. M -N M I M 4M Z we a w .J E EL 0 Ug KoHuNMAPMNonoWNdoMM o > 5 S S I M. CL =..J W W EL M k M M E k e N D >= 0 C M M d o m o o o N N e4 U o. N 4 P1 o d Z l N M M N 2 2 = ,I o .i o i W l O M Z is M w t !I e ls eeo ooooooooooooooo .x 14 4 a es M u w 'l O' k
- t u
o r 9. O M i M .J O U O> as O EUW W W W 3 2 2 3 p M b M W :' he z MWM M2M Z22 O a 3tr2MWWWMMMMM3 33222> W M EL O 1_ _, in - .m.- = a s-e
..____m_ g ~ 24 HCUR
SUMMARY
OF WIND SPEED DISTRIBUTION 15 FPC - CRYST'AL RIVER 175 FT HINDS (SIG THET A) MAR 1975 b TOTAL NUM3ER OF READINGS T.05000E+02 TOTAL NUM9ER OF READINGS WITHOUT CA L MS 7.05000E*02 ~
- g WIPO' SPEED DISTRIDUTION, NO 0F 005.
LT.5 .50-3.5 3.51-7 5 T.51-12.5 12 51-18.5 18 51-24 0 GT 26.5 1 10 59 261 229 89 56 SUNPED OVER ALL DIRECTIONS ld WIND SPEED DISTRIBUTION VERSUS STABILITY CLASS (NO OF CBS.) F A B C D E F G 1 0 0 0 0 1 0 0
- 2 2
1 0 2 3 0 2 3 0 4 4 17 13 15 6 0 0 2 10 56 88 61 44 5 0 0 10 40 79 TT 23 6 0 0 1 3 22 39 24 7 0 0 0 1 25 22 8 e 45 t 5d
i_ m 'lli 'd FPC - CRYST,*L RIVEa 175 FT WINDS (SIG THETA) H AR 19 75 16 i' 8 o SUMMED OVER ALL ST ABILITIES WIND SPEED VERSUS DIRECTION (IN NUMBER OF 085 9 WIND WIND SPEED (MPHI AT 53 METER LEVEL DI;ECTION 1-3~ 4-F 8-12 13-18 19-24 >24 TOTAL NNE 1 6 10 13 1 0 31 hE 1 3 26 23 0 0 53 ENE 1 3 20 10 0 0 34 E 2 0 23 45 1 0 71 ESE O 5 9 18 1 0 33 SE O 5 27 6 0 0 40 -5SE O 3 2C 13 1 0 37 5 1 4 20 17 6 6 54 SSW 0 4 14 19 25 29 91 1' SW D 3 16 16 24 11 70 WSW 1 1 10 3 2 1 18 W 0 T 18 4 4 2 35 WilW B 3 12 18 18 3 54 NW i 4 14 8 4 4 35 NNW 1 4 10 7 1 0 23 N l' 4 12 7 1 0 25 TOTAL 10 59 261 229 89 56 704 PERIODS OF CALM (No. OF HOURM - 1 39 Q MISSING DATA (NO. OF H0tJRS) .g-e )
l 1 i 1 I >m. e l 1 1 I I l l 1 I l \\ l 1 I I I I I 1 l' g 1 I I .J .J 4 4 l k k O O l WOMOHOOOOOOOOOOOON HNowoNwpOOOwpOOOON I I i, 5 M M 2 i G N O N O A OOOOOOOOOOODOOOOO O ADODOCODOGO COODO l' l b b l M D W 4 e W 2 l O N O N D. x .J e x J. I D W O' D D W 05 M 2 DdOOOOOOOOOOOOOOOOO e 2 >HODODpoOOOOOODDOOO l .= W D W t 05 2 .J G 2 .J 5 w M e M l w E o as IK e E W D W l 4 2 D. O e Z O 2 O Mw e O-Ww l M ri z. M n M i 4 O MMOOOOOOOOOOOOOOOOO O MMOOOOOOOOOOOOOOOOO e W M w M 1, W <e ce z M M s 0 e O k e W D 4 i O MM 9 MM g M MD e= N e MD .N s M et M ZM O 6 4M ZM e w se ai su si l og 5cOOOOOOOOOOOOOOOOO vy SO-OOOO-DOOOOOOOODN O l 2 >O g a >O O 3 M MW MW W .e I o sw W sW W Ma a M Ma s M l .O M M W .s .O M M g 6 O O I kO O. O e 60 08 O M MM 2#OOOOOOOOODDOOOOOO Z D M4 Z4HONONDOODOOOODO04 Z I >= M M e M M .e 3 3 i k e 3 2 k O O l-B l c Q M 2 2 l s 9 M. M. w w l s wnwOwpOOOOOOOOOOON E MOOOOOOOOOOWOOOOOW d 4 .J .J 4 e M u o I 1 "u 'o b 2 2 i e' O M O M i M .J O M .J O U O> 4 O O> e Q l 20W W W W 3 2 2 3 M 20W W W W 2 2 2 3 M k MWZWZ MWM M2M 232 0 M W '/ W 2' MWM M2M 222 O E l EEZdWWWMMMMMX2322ZW W 3EZZWWWMMMMM333 3ZZW W M a M EL I O-O I I i 2"v. = 3 JN"! PTS M** M. i ] e
- aw ara *-
pe
4 _-- _ 7__ ; 7_-- - ._ g __ __ ___g__ i FPC - Cif"TAL CI"Ec 175 FT WIN 05 (SIG THETA) MAR 1975 18 StanILIT Y CL ASS C WIh0 SPEED VERSUS DIRECTIOh (IN NUMBER OF CBS.) k!N1 WING SPEED (MPHI AT 53 METER LEVEL DICEC T IO N 1-3 6-7 8-12 13-18 19-24 >24 TOTAL I hNE O O 1 0 0 0 1 NE O 1 3 4 0 0 8 ENC 0 0 1 1 0 0 2 8 E 'O O 1 1 0 0 2 l1 ESE 0 1 1 4 0 0 6 SE O O 3 0 0 0 3 SSE O O O O O O O S 0 0 0 0 0 0 0 SSW D 0 0 0 0 0 0 SW D 0 0 0 0. 0 0 WSW D 0 0 0 0 0 0 W G 1 0 0 0 0 1 WatW 0 0 0 0 0 0 0 hw .0 0 0 0 0 0 0 N'J W 0 0 0 0 0 0 0 N 0 1 0 0 1 0 2 ] 10TAL 0 4 10 10 1 0 25 PERIODS OF CALH (HO. OF HOURS) 0 ST ABILITY CL ASS D WINO SPEED VERSUS DIRECTION (IN NUHUER OF CBS.) WING HIND SPEED (HPHI AT 53 NETER LEVEL DIRE CT.in N 1-3 .-T 8-12 13-18 19-24 >24 TOTAL 11 NME 1 1 1 2 0 0 5 NC D 2 20 10 0 0 32 ENE O i 8 2 0 0 11 E O O 4 9 0 0 53 ESE O O 3 4 1 0 8 SE O O 6 5 0 0 11 SSE O O O 3 0 0 3 S 0 2 1 0 0 0 3 SSW 0 3 1 2 1 1 6 SW D 2 4 3 0 0 9 hSW 0 0 3 0 1 0 4 W 0 3 1 0 0 0 4 l' WNW 0 1 2 0 0 0 3 II NW 0 0 2 0 0 0 2 NNW i 0 0 0 0 0 1 h 0 2 0 0 0 0 2 TOTAL 2 17 56 40 3 1 119 PERIODS OF CALM (HO. OF HOURS) 0 A
_..n _--.. - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _. T.__ I FPC - CivsTAL RIVER 175 FT WIN 05 (SIG THITA) MA2 1975 19 ST ADILIT Y ~L ASS E WIhD SPEED VERSUS DIREC TION (IN NUMeER OF 083.1
- g WINO WIND SPEED (M PI'1 AT 53 METER LEVEL Ih OIRECTION 1-3 4-7 8-12 13-18 19-24
>24 TOTAL NNE O 3 3 6 0 0 12 NE O O 3 8 0 0 11 ENE 1 0 10 4 0 0 15 E - 0 0 5 22 1 0 28 ESE O O 2 8 0 0 10 SE O 2 9 1 0 0 12 SSE O O 5 2 0 0 1 S 1 1 7 5 3 4 21 SSW 0 0 4 5 7 14 30 SW 0 1 8 5 8. 6 28 {l WSW D 1 5 3 0 0 9 W 0 1 11 1 0 0 13 WNW D 1 7 5 2 1 16 NW 0 1 5 3 1 0 10 N'4 W D 2 2 1 0 0 5 N i O 2 0 0 0 3 TOTAL 3 13 CS 79 22 25 230 PERIOOS OF CALM (NO. OF HOUR $9 i STABILITY CL ASS F WIND SPEED VERSUS DIRECTION (IN NUMBER OF 08S.9 WINO WIND SPEED (HPN) AT 53 METER LEVEL DIFECTION 1-3 4-T 8-12 13-18 19-24 >24 TOTAL N'IE 0 0 1 3 0 0 4 NE O O O 1 0 0 1 ENE O 1 1 3 0 0 5 E O O 5 12 0 0 17 ESE O 1 1 2 0 0 4 SE O 3 5 2 0 0 10 f3 SSE O 2 11 3 1 0 17 S 0 1 7 9 3 2 22 SSW 0 1 4 7 8 7 27 SW 0 0 3 4 4 5 16 WSW G 0 2 0 1 1 4 W 0 0 6 3 4 1 14 WNW G 1 3 12 14 2 32 NW 0 3 5 5 3 4 20 hNW 0 2 3 5 1 0 11 N O O 4 6 0 0 10 TOTAL 0 15 61 TT 39 22 214 jfl PERIODS OF CALM (NO. OF HOURSI 0
- 4
a W e F N ) e .g ~ 1 l .I 1 i I l e i I I I I I I I I I s* I a I ena..nna.enannne.~. g N-I I ~ i m 4 g 8 "........~....... ~ t b a W GD N I z s. o we l m 2 >Mdoo. coco @NO.NOOO I e = s ~ W W 5 I, z o .W.4 s M = I sin be M 4 O M e4 N O O e4 O O m M m J G W e4 O v4 e4 M l b= W m N W OW i Z M l o I -) o we i - mo . N. n 4n l - se & ,, up 5 n...unemm-...Nm g o - g I 5, Z8 8 8 sW W 1 -s a D. Er M M l A D k
- 4. o o.
o g ~ Z m HE 44domadadoomoNonode ~ ~ ~ 3 6o I n W I I o E H Z l Elf M w I w'. o. m o o o o o o o o o w o o N s z j. 4 .J t= 4 1 m e 5 b i z e o m i M .J o O D >= 4 o l' 2UW W W W 3 2 2 2 >= w f k HWZW2 MWM M3M Z32 o I 3 EK K Z W W W m H M M M 3 2 J a z Z > W I M O l. I I-53 s g gg =, : .s
a .t' 8 24 HOUR SUMMA 5Y OF WIhD SPEED DISTRIBUTION 16 FPC - CRYST'AL RIVER 115 FT WINOS (SIG THET Al - APR 1975
- 9..
TOTAL NUM9ER OF RFACINGS 6.61000E*02 TOT AL NUM9ER OF RE ADINGS WITHOUT cat MS 6 61000E*02 WIhD SPEED DISTRIBUTION, NO OF 085.- g LT.5 .50-3.5 3.51-7.5 T. 51-12. 5 12.51-18 5 18 51-24.0 GT 24.0 0 11 83 261 246 39 21 .....ee...e. SUMMED OVER ALL DIRECTI0h5 ) HIND SPEED DISTRIBUTION VERSUS STABILITY CL ASS (NO OF OBS.) A B C D E F G 1 0 0 0 0 0 0 0 2 1 0 4 3 1 i i 3 2 4 11 30 27 7 2 0 2 2 20 89 106 32 10 5 0 0 4 75 131 28 8 6 0 0 1 4 24 9 1 7 0 0 0 1 18 2 0 n e e
_______.________-____________._____________a. Y jv b .FPC - CtVSTAL RIVER 175 FT WINDS (SIG THETP.) APR 1975 17 4 9 or....................n,........ SUMMED OVER ALL STABILITIES WIND SPEED VERSUS DIREC TION (IN NUNEER OF 035.4 WIND WIND SPEED (MPHI AT 53 HETER LEVEL DIEECTION '1-3 4-7 8-12 13-18 19-24 >2 4 TOTAL ENE O 2 19 is 0 0 39 bE 3 5 16 6 0 0 30 'ENE O 8 14 13 1 0-36 E O 5 10 35 0 0 50 ESE 2 3 1* 15 2 0 34 SE 1 4 19 8 0 0 32 SSE 2 7 to 5 1 0 33 S. 0 6 19 15 2 0 42 SSW 0 5 16 18 10 2 51 ]Il SW G 7 14 24 16 2 63 'd hSW 1 4 12 15 0 6 38 W 2 8 24 11 2 1 48 WNW 'O 9. 23 16 1 2 51 kW 0 6 L4 19 3 8 60 ENW O 2 8 11 3 0 21 N O 2 13 17 1 0 33 TOTAL 11 83 261 246 39 21 6E1 PERICOS OF CALM (NO. OF HOURS) O y MISSING DATA (NO. OF HOURSt - 59 ill 4 et e
- i$
l O M e 0 O O 0 0 1 1 I i i g I I i I e l I I I 1 a s I = a >= t-O O l kwNewppdOOOOOOOOOM WModWOOOOMMOHOOOO@ l 1-t I M d M M O N O N I O aOOOOOOOOOOOOOOOOO O aOOOOOOOOOcucc3DOOO j b b l W W 4 e W 4 l O N O N x s. z ai l D WP . = D WP a th Z > W O O O O E3 C3 O O O O O O c3 O O O O 2 > w1 O O O O O O O O O O O O O O O O O l P. W W t 9 2 a Z .J l et M e.e l w W w E e W ad W l S. z ee 2 >c W Q td we O W we E 9 M E8 i M. ca 6 M F1 l W O MMOOOOOOOOOOOOOOOOO O MMOOOOOOOOOOOOOOOOO W M W M i W .u De z ~ ~ l c > O k SD MM MM M M3 mN MD mN I M .M x-O <M zu o w se as . se ai g Ug EOMOOHGOWOOOOOOOOON g gGWOOMOOOOOOOOOOOON Q O 2 t= 0 -O g >O O l M MW W MW W .g a sW w . sw W ~ e. a M ~n a M l E OM M. w OM M D D O w - .I O -O O. O -O M mz z.,OuuGOO-DOOOOOOOON z. Me z#OOwcOOOO--O-DOOO,. z -l M 2 = u. 2 2 u. s O O C7 i ea D O e O g M 2 Z
- l E
m. w m w 6 6 .l .J we O we o es O O O O O O O O O O O C e4 E M O O O em t2 O O O O O O O O O C3 O O E = s s
- 1
= = M u u i W k LL U O O z-2 I 4 O M C M e-e .J O H .J O 'i ' O 0= 4 O O >= 4 O U 'I C) 2OW td td W 3 3 2 2 e-e.4 2 O td W Id W 3 2 2 2 4-M 46 HtdRWZ M ad M M2M =2 O y M W Z td z MWM M2M nTz O E W 3ta 4 z W W W M M M M M.s 2 3 4.Z Z e. W -l-3 a.scsc w w w M M M M M a 3 3 3 Z Z e. e. a e l O O l-l
== a= w: =a: m 'et mw-Des
- * =
w
w. f a
- :r "g
FTC - CtYSTAL 9IVE8 175 FT WINDS (SIG THET A) APJ 19 75 19 ST ABILITY CL ASS. C 1 WIND SPEED VERSUS DIRECTION (IN NUMEER OF 085.0 WIND WIhD SPEED (MPHI AT 53 METER LEVEL DIoECTION 1-3 4-T 8-12 13-18 19-24 >24-TOTAL kNE O O-7 0 0 0 7 hE 1 0 4 0 0 3 5 ENE O i .2 0 0 0 3 E O 1 3 2 0 0, 6 l'H ESE O 1 1 1 1 0 4 SE 'J 1 0 0 0 0 1 SSE 1 1 0 0 0 0 2 S 0 1 1 0 0 0 2 SSW 0 0 0 0 0 0 0 SW 0 1 0 0 0 0 1 WS W 1 2 0 0 0 0 3 W 1 2 2 0 0 4 5 WNW 0 0 0 1 O O 1 NW G 0 0 0 0 0 0 kNW G 0 0 C 0-0 0 h 3 0 0 .0 0 0 0 !..N. TOTAL 4 11 20 4 1 0 40 PEP.IODS OF CALM (NO. OF HOUR $1 - O ST ABILITY CL ASS D WIND SPEED VERSUS DIRECTION (IN NUMBER OF CBS.) WIND WIND SPEED U* PHI AT 53 METER LEVEL DIEECTION 1-3 4-7 8-12 13-18 19-24
- 24 TOTAL IU hNE O
2 7 6 0 0 1T NE 1 3 11 5 0 0 20 ENE O 4 10 9 1 0 24 E. 0 0 0 9 0 0 9 ESE 1 1 6 7 1 0 16 SE O 1 2 4 0 0 7 SSE O 2 1 2 0 0 5 5 0 5 8 5 1 0 19 SSW G 3 11 2 0 0 16 SW 0 1 8 8 0 0 17 WSW G 1 6 2 0 0 9 W 1 2 10 2 0 0 15 i$ kNW D 4 6 4 0 1 15 hv 0 0 0 4 1 0 5 kNW 0 0 2 2 0 0 4 N O 1 1 2 O O 4 TOTAL 3 30. 89 75 4 1 202 e PERIODS OF CA(M (NO. OF HOURS) 0 ,.f)
st. l I I I O~ I l l 'l l i I I I 1 l .I l I .l LI l I I l s .I = s. .= 0 O l M O.4 M N N N o. m.@.N M m N M - e c.N k N O - m - N,. N M N O - O N N N.,. ...NMuNnm .O .4 = .l n .I I I a m I 8 N (D N A O O O O O O O O N e4 @ v4 O C O O e O A O O O O O O O O O e. O O e4 O O O N .l b b 'i. = W W -f I N = N x s. x s. l o we o We m z > *4 O O O O O O v4 v4 P= O O N *e N O O 3 7 > - O O O O O O O O n m O O O O O +4 G l. N W N W I e.4 z s z a -l a - a e W W a =. =. = -O o W.4 o W-z. ~ z. ~.= n .= M 'l M.4 N e4 4 @ @ M A O J, PS @ e4. m.4 4 O @ @ e4 O M e4 N O O N O e4 O O N N O O O O M @ e m 44 4 n W m N W I w wu wu .x ~ ~ .I o.= o.= i a mm mm - wo -~ mo -N I a .m z. 0
== z-O a4 - seog 5 n--44N.mmm@N@g-g og 3OO---eNnN-CO--nNg se a i I ,o 1 z.= o i o o -W .w W i 3 sW W sw W ~a a m -a a e l .= mm m v .e m m w ~ o. u. N = =o o. O -o o. o m n4 2 4 O e4 N N we O PO O e4 M O #4 m 4 e. v4 P= z mZ Z J O O O N O e4 O O O e4 # C O +4 ee O N z N - ~ x s u. m = u. l D C i a W l o C m z
- a
= l .s -O000-O0000000000-m -O0000-0000000005-z s. s 1 .= .m u o I .I 3 b b = z .I' O m o n l M J O M .J O O o-O o b= 4 0 g Z p uk W W W 3 2 3 X >= M zUW W W W 2 2 2 2 .= M 6 e-eW 2 W Z mWm m2m Z27 o M ha Z ks Z m hJ m m2m =32 E 2 E 4 2 W W W H m m Wtra3 3 3 z K =.o i 3 su 4 x w W w a m m m m A 3 3 4 4 2 >- w = w H M a 1. a o .I 1 m 5 !!H In Of , : s
7-e e4 N n l I I i i I I I
- g I
1 I I 1 I s. I 4 6-O > e4.. @ e4 N M N. es... N N N N e I l I I M a j s N................. s I e W N l E' .J t o WP g g Z Wo........M .....H I z a ~ l w E e w l EL 2 m. 4 O W +4 I M E 9 am n I 4 O M e4 *4.. @ e4..... Ce...... I W M W O (C I E M O t= 0 MM - Mo -~ l' Z+ M 4M s4 - su , oy .....-NN.....wNNg z
- O
>= 'i E >O O l l M MW W -e 3 .J W W. m I w (L CL M e-EM M W 'l 4 D= 3 >O O O O l 44.....W.....O.W..N Z M H.2. ~ N we 2' 2 Rh 'l O I 9, I 0 z g s. I = s. 't 8 = j' (i U ^ Q 1 x .8 O M I-H J O U O> g C .g (L 2OW b8 W W 2 2 2 2 M 3 te, M W r hJ = M bl M M2M Z22 O a 2 u 4 4 W W W M M M M M JE 2 3 g 2 A p= W* I E .I l' 11 - =,2 55 E2 Es 52 7 s, e
_._--..---.--__.--.._:.2--__.-.,_____. IP ~ .J 24 HOUR SUFMA5Y OF wit.D $8EED DISTRIBUTION 15 FPC - CRTSTAL RIVER 175 FT WINDS (SIG T HET A) MAY 1975 -TOTAL NUM1ER CF READINGS
- 7. 290 0 0 E+ 02 TOTAL NUM9ER OF READINGS WITHOUT CALMS T. 2'3 0 0 0 E + 0 2 WIND SPEED DISTRIBUTION, N0' 0F CBS.
LT.5 .50-3.5 3.51-F.5 T. 51-12 5 12 51-18 5 18 51-24.0 GT 24.0 0 21 126 35T 203 16 6 lN ' a SUMME0 OVER ALL DIREC TIONS WIND SPEED DISTRIBUTION VERSUS STABILITY CLASS (N0 0F 085.3 A B C 0 E F G 1 0 0 0 0 0 0 0 2 1 1 3 8 6 2 0 3 6 8 22 49 29 9 3 4 0 2 21 13T 132 43 22 5 0 0 5 ST 121 13 7 lF 6 0 0 0 2 13 1 0 7 0 0 0 0 6 0 0 e 4 1.1 .!U
. ;<rst3L.*1vCD 175 i T DIN 05 (SIG THETA) M AY 1975 16 SUMME0 OVER ALL STABILITIES %IND SPEED VERSUS OIRECTION (IN NJMDER OF 095.8 WINO WINO SPEED (MPH) AT 53 HETER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL hNE O 8 6 3 0 0 17 NE 3 5 13 3 0 0 24 ENE 1 7 17 11 0 0 36 E i 15 29 15 0 0 60 ' g* ESE 1 12 17 11 0 0 41 SE 3 8 45 8 O O 64 SSE 5 13 44 3 0 0 65 S 0 4 17 3 1 0 25 SSW 1 3 10 7 0 0 21 SW 1 7 18 16 7 3 52 WSW 2 6 15 13 3 0 39 W 0 8 55 31 3 3 100 kNW 3 7 28 47 2 0 87 P;W 0 9 16 26 0 0 51 t;NW O 4 14 3 0 0 21 I'dI N O 10 13 3 0 0 26 TOTAL 21 126 357 203 16 6 729 PERICOS OF CALH'(NO. OF HOURS) 0 15 HISSING DATA (No. OF HOURS) e t e .lh 0 k
y m v 7 1 v_ L L A A T T O O T111O0110000001107 T0i0C2OO2011101021 1 3 3 5 4 5 4 8 2 9 2 0 >O00O0000000000000 0 >000O0OO4 000000000 F F O O R R E 4 E 4 B 2 B 2 M L - M L-U E9 U E9 5 N V1O00O0000000000000 N V1000O0OO0000000000 7 E E 9 N L N L 1 I I ( R ( R T E E A N T8 N T8 M O E1 O E1 I M - I M- ) T 3 T 3 A C 31O00O0000000000000 C 31000O0OO0000000000 T E 5 E 5 E A P. BR H I I T C T D T A A G SS SS I SU I 2 SU l 2 S AS H1 0 AS f1 0 ( LR P - LR p-CE M8O00O0000000000CC0 CE M8000O1OO1000000002
- S V
( V ( D Y Y N TD D TD D = I IE E IE E W L-E E ) LE E ) IP P S IP P S T BS S R RS S R F A T U A 7 U TO G - ' O TD D-O 5 SN N4111O01000000011O6 H Sh N 4 0 0 0 O 1 O O 10111010 2 8 - H 7 I I I I 1 W D F W W F O O Q E V o O I N N R 3 ( 3 ( L 10OOO00100GD000DO1 M 1o10OOOOO000D00DO1 M A L L T A A S C C Y . C O O R F F N N O S O S L O I L O I C OT A C DT A O C NCE E E E W W W W T I NCE E E E W W W W T I F IENEN SES SWS WN O R IENEN SES SWS MWN O R J W R N N E E E S S 5 S S W k 'W N N N T E WRNNEEESSSSSWWbkhNT E I P I P D D W Ha Q } [* f" t .I
- I
_________________.____E ________.m___________.______________ FPC - CRYST AL 4IVER 175 FT CINDS (SIG THETAI M AY 1975 18 ST ABILIT Y CLASS C WINO SPEED VERSUS DIRECTION (IN NUFBER OF 06S.) s!l WIND WIND SPEED (HPHI AT 53 METER LEVEL I8' OI9ECTION 1-3 4-1 8-12 13-18 19-24 >24 TOTAL ENE O 2 0 0 0 0 2 NE 0 1 3 0 G 0 4 ENE 1 1 1 2 0 0 5 E 1 2 5 3 0 0 11 ESE O 2 0 0 0 0 2 SE 0' O 1 0 0 0 1 SSE 1 3 0 0 0 0 4 S 0 0 1 0 0 0 1 SSW 0 1 0 0 0 0 1 SW O 4 2 0 0. 0 6 lH WSW G 2 2 0 0 0 4 W 0 1
- 5 0
0 0 6 hNW 0 1 0 0 O O 1 kW 0 1 0 0 0 0 1 NNW 0 0 0 0 0 0 0 N O 1 1 0 0 0 2 TOTAL' 3 i'2 21 5 0 0 51 PERIODS OF CALM (NO. OF HOURS) - 0 ST ABILITY CL ASS D WIhD SPEED VERSUS DIRECTION (IN NUMBER OF CBS.) WIND WIND SPEED (H P HI AT 53 HETER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >24 TOTAL hNE 0 4 2 1 0 0 T NE 2 1 10 2 0 0 15 ENE O 4 3 5 0 0 12 E O 5 9 1 0 0 15 ESE 1 5 2 1 0 0 9 SE o 2 10 3 0 0 15 R SSE 1 4 12 2 0 0 is S 0 1 8 1 1 0 11 SSW 0 1 8 3 0 0 12 Sw 0 2 11 5 0 0 18 WSW 2 3 12 8 0 0 25 W 0 5 26 9 0 0 40 WNW 2 4 16 9 1 0 32 WW 0 2 4 6 0 0 12 NNW 0 0 3 0 0 0 3 N 0 6 1 1 0 0 6 TOTAL 8 49 137 57 2 0 253 e {t PERIODS OF CALM (NO. OF HOURS) 0
M. ig MAY 1975 19 FPC - C1YST AL CIVER.175 FT WINOS (SIG THETA) STABILITY CLASS E WIND SPEED VERSUS DIRECTION (IN NUMBER OF 085.9 WIND WIk0 SPEED (MPHI AT 53 METER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24
- 24 TOTAL hNE O-1 3
2 0 0 6 NE O 2 0 1 0 0 3 -E4E ~0 1 11 3 0 0 15 E 3 4 5 5 0 0 14 ESE O 1 1 3 0 0 5 !} U SE 1 4 25 3 0 0 33 SSE 2-5 17 1 0 0 25 'S 9 1 4 2 0 G T SSW 1' 1 2 4 0 0 8 SW 1 0 5 11 7 3 27 WSW 3 0 1 5 3 0 9 W D 1 22 22 2 3 50 WNW 1 2 12 36 1 0 52 NW G 3 10 19 0 0 32 NNW D 2 9 3 0 0 14 N O 1 5 1 0 0 7 TOTAL 6 29 132 121 S.3 6 307 jlf PERICOS OF CALN (NO. OF HOURS) 0 ST ASILITY CL ASS F WIND SPEED VERSUS DIRECTION (IN NUMBER OF 085.8 WINO WIND SPEED (MPH) AT 53 METER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >2 4 TOTAL jil NNE o 0 1 0 0 0 1 48 NE O O G 0 0 0 0 ENE D 0 1 1 0 0 2 E O 4 6 3 0 0 13 ESE O 1 7 5 0 0 13 SE 2 1 7 1 0 0 11 SSE O O 9 0 0 0 9 5 0 1 2 0 0 0 3 SSW G 0 0 0 0 0 0 SW D 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 W 0 0 2 0 1 0 3 l2 WNW 0 0 0 2 0 0 2 M NW 0 1 2 1 0 0 4 NNW G 1 1 0 U 0 2 h 0 0 5 0 0 0 5 TOTAL 2 9 43 13 1 0 68 0 PER1005 0F CALM (No. OF HOURS) .M
- 3. J'l
9 0 9 7 f. N p b i 1 l- ) ~ ) ) D F. I I I I I a I 4 e 6= 6 O I >= O e M P. O PS A e4 O O O. O O e4 N N W M .I I I M 1 8 7.o............ooo I b i e W s l M N z ao l P WP z e gwooooooooo...ooooo e P 2 =J 4 e4 M W T l W 4 2 n= so l 3" O W4 l M E B P1 s= - l 4= W M o nuo .nNuooooooo..-~ i W or z M i O l o MM Mo ~ } M 4M .k og O - s e
- a..
g WW EmmaWJ4N@MOppeGoHMN k O 1 2-n= 0 O I M MW W g 3 JW W M a. a M l t= ID M - M.= tr u. 4 a l' e= O 0,I C m-M. z. ....No-o..... oon z l 9 M M 3 3 i I O n 1 . W e + O
- o eo z
GK M w 0 { d v4cooneocoomanOOmott E 4 a { k 4 s M o .( - ff (L l. 0 O .= 4 0 O M g M O e' O O t- . 2 2 3 M 88 ' O lz <h zOW W W W 3' la. ' MWZW2 MWM M3M Z32 O W g. 3 QC Z K W W W M M M M M 3 3 4 4 4 E e= W M e. l-O l: is n. _ ;..... !!!!E! ' Ed E! E2 Ei
~ ....'s __.:w N .3 24 HOUR SUMMAEY OF WIND SPEED DISTRIBUTION 15 FPC - CRYSTAf. RIVER 175 FT WINDS (SIG THET AB JUNE 1975 ~ TOTAL HU9 ER CF READINGS T.08Cn3E+02 TOT AL NUM3ER OF RE ADINGS WITHOUT CALMS T.G8000E+02 1 M o 5-WIND SPEED DISTRIBUTION, NO OF OBS. LT.5 .53-3.5 3.51-7.5 T. 51-12 5 12 51-18.5 *18 51-24.0 GT 24 0 0 23 137 380 150 16 2 4 1 SUMMED OVER ALL DIRECTIONS WIND SPEED DISTRIBUTION VERSUS STABILITY CL ASS (No 0F CBS.) A B C D E F G 1 0 0 0 0 0 0 0 2 1 2 8 8 2 1 1 3 8~ 8 25 61 20 11 4 4 1 6 35 174 111 33 20 j' 5 0 0 3 56 80 7 4 g 6 0 0 0 2 14 0 0 T 0 0 0 0 2 0 0 I 1 e
u._. ._a_c.__:
- a_____
_as FPC = CRfSTAL' RIVE 2 175 FT t:INOS (SIG THETA) JUNE 1975 16 q g 1 m SUNNED OVER ALL STABILITIES WIN 3 -SPEED VERSUS DIFECTION (IN NUMBER OF CBS.3 b!NO WIND SPEE0 (MPH 3 AT 53 METER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N'4E-3 8 12 3 0 0 26 NE 3 13 34 6 0 0 56 ENE 1 8 48 12 0 0 69 fl. E 2 13 27 5 0 0 4T T A-ESE 3 8 22 3 0 0 36 6 - SE 3 13 18 2 O O 36 SSE~ 1 ~17 35 0 0 0 53 S 1 8 1T 1 2 0 29 ~ SSW 1 1 15 3 1 0 21 SW 1 9 13 5 0 1 29 WSW 0 4 37 16 0 0 57 ~ b i 10 36 38 12 1 SS WilW 1 6 36 37 1 0 81 NW 1 3 13 16 0 0 33 NNW 1 6 4 3 0 0 14 N 0 10 13 0 0 0 23 l q TOTAL 23 13T 380 150 16 2 708 PERIOUS OF CALH'(NO. OF HOURS) 0 MISSING D ATA (NO. OF HOURS) 12 ]a 1 O 9 AF J m
I p. e4 k I a e 4 e 9 .J at 4 >= >= 0 O t= c e4 o o e4 c3 o a Es we o M N O e4 e4 ce > N N *4v4 N e4 o o o N o w +4 o e4 N @ .4 v4 m e e e M J M 4 O N ED N O A oEs o cscsen e oczeses a o Es e o Es o A o oo e o o*==c3o ocmaso o ocso b b 1 1 W e W W 3 e W 4 ) o N e ED N } E J 8 o E .J 8 M D W c5 e D WM l A Z > og 3 o o ce *3 o o o c3 o o o o o o o es o Z > *8 o o o o o o es o o o o o o o o o o to W e W } .Z.4 J w 2 J e e ) W w o w W z W W ) D 2 km o E km
- 3 O
We e O W v4 ). M E e o M Ee = t= po o 0-M ) 4 O M we o cz o o o o o o o ca o o u o o es ca e o r1 4 c3 o o o <a o o o o o cz ca cm o o cm o 1 t-W W e W W l W at QC e O Q( ] Z M e M / O t-o O t. } 4 o 4 } Oe MM e MM e M3 mN e MD = N.4 Z o e 4M Z ** cs M et M ) w s2 mi e se a. E e o o o se em o ca o o u o et cm o o Es,4 e uW go tw cm o o.4 a ca ca o.4 c3 cm cm o e v4 @ Og O e 1 J Z >Q O I e >= 0 O g a M >< W W e MW W J D IW W m o .J W W = T M (L dL M e M4 sk M J b= ED M M W e ED M M E ]. 4 as N D e et A D k g* OI O e >O Of O l 6 M .M J e w o o w o o o o o n N N u w w e .e 2 M4 ZJowwwowooowowwoowe Z 4 .e M ~ l w 2 2 L e 2 2 6 O O I = W e e l C O e M 2 2 1 d M w M w .e
- I g
.a e cs es Em o o o o o o.4 a o c.8 o o cm.4 I 4 o.4 o es ce o o o o o o o a u o o r. g 4 .J b= a er 8 M U U s= W k k (J Q Q 2 2 4 O M O to i. .J O M .J O O O *= es O O t= ac O EL 2OW 'W W W 3 2 2 2 e s.e 2uW W W W 2 2 2 2 a= M t E MW2W2 to W M M2M 7TZ O W MWZW2 m bJ M M2M 222 O T e l4 2 EE 4 2 W W W M v3 M M M 3 2 3 2 2 Z e W 3 tr Z M W W W M vs M M M 3 2 3 4 2 Z > W i M M (L lI. O O l
- l.
}l FE3 2.. T 111 1 33.". u.m C,. 7 w. e g..e m
7- -c=..._a_-- ~ ~ - - FPC - CtYSTAL RIVE;t 175 F7 WIN 05 (SIG THET*.I JUNE 1975 18~ i STABILITY CL ASS - C WIND SPEED VERSUS DIRECTION (IN NUMBER EF 085.9 Ig ; UINO WIND SPEED (HPHI AT 53 METER LEVEL DIPECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL ANE 1 2 2 2 0 0 7 NE D 3 4 0 0 0 7 ENE O 3 9 0 0 0 12 E 1 1 4 0 0 0 6 ESE 1 1 2 0 0 0 4 SE 0 1 1 0 0 0 2 SSE 1 0 0 0 0 0 1 S 0 3 0 0 0 0 3 SSW 1 0 1 0 0 0 2 SW 3 3 1 0 0 0 4 q hSW C 2 4 0 0 0 6 1*{ b 1 0 1 0 0 0 2 WNW 1 1 1 0 0 G 3 NW 3 1 4 1 0 0 6 hW 1 1 0 0 0 0 2 N O 3 1 0 0 0 4 TOTAL 6 25 35 3 0 0 71 PERIOOS OF CALM (NO. OF HOURS) 0 til ST ABILITY CL ASS 0 WIND SPEED VERSUS DIRECTION (IN NUMBER OF 095.) WINO WIND SPEED (MPHI AT 53 HETER LG EL' OIRECTION 1-3 4-7 8-12 13-18 19-24
- 24
- TOTAL NNE 2
6 3 1 0 0 12 NE 1 7 28 5 0 0 41 (NE 1 2 14 5 0 0 22 E 0 7 9 2 0 0 18 ESE 1 5 5 0 0 0 11 SE 2 T 2 1 0 0 12 SSE O 7 7 0 0 0 14 j'] S 1 3 4 0 1 3 9 SSW D 1 1C 1 0 0 12 SW 0 2 7 2 0 0 11 WSW 0 1 26 7 0 0 34 W 0 4 29 13 1 0 47 l WNW c 0 21 13 0 0 34 NW D 2 5 4 0 0 11 NNW G 2 1 2 0 0 5 N 0 5 3 0 0 0 8 TOTAL 8 61 174 56 2 0 301 1% 0 i PERIOOS OF CALM (NO. OF HOURSS W .e
1) .;q FPC - CIYJTAL RIVEP, 175 FT WINDS (SIG THETA) JUNE 1975 19 ST ABILIT Y CL ASS E WIND SPEED VERSUS DIRECTION (IN NUMBER OF 08S.8 WIND WIN 3 SPEED (P PH) AT 53 HETER LEVEL DIDECTION 1-3 4-T 8-12 13-18 19-24 >2 4 TOTAL NnE o O 4 0 0 0 4 NE D 1 2 0 0 0 3 ENE. 0 1 18 4 0 0 23 E 1 3 2 0 0 0 6 !M ESE - 0 1 9 C 0 0 10 'd SE O 2 it 1 0 0 13 SSE J 3 iT C 0 0 20 S 0 1 8 0 1 0 10 SSW 0 0 3 2 1 0 6 SW d 3 3 3 0 1 10 bS W i 0 7 9 0 0 16 W 0 3 5 25 11 1 45. Ic4W 0 1 14 24 1 0 40 NW i 0 4 11 G 0 16 N'4 W D 1 b 1 0 0 2 N O O 5 C 0 0 5 TOTAL 2 20 111 80 14 2 229 1'W PERIODS OF CALM (NO. OF HOURS) 0 i ST AOILITY CL ASS F WING SPEED VERSUS DIRECTION (IN NU10ER OF CBS.) WIND WIND SPEED (MP H AT 53 METER LEVEL DIPECTION 1-3 4-T 8-12 13-18 19-24 >24 TOTAL E!IE O O O O 0 0 0 I] NE 1 0 0 1 0 0 2 ENE O 1 5 2 0 0 8 E O i 6 0 0 0 7 ESE O 0 3 3 0 0 6 SE O 1 3 0 0 0 4 SSE O 4 7 0 0 0 11 5 0 1 4 1 0 0 6 4 SSW D 0 1 0 0 0 1 SW 0 0 1 0 0 0 1 WSW 0 1 0 0 0 0 i W 0 0 0 0 0 0 0 WNW 0 1 0 0 0 0 1 j'jd NW 0 0 0 0 0 0 0 NNH 0 1 1 C 0 0 2 N O O 2 0 0 0 2 TOTAL 1 11 33 7 0 0 52 0 PERIODS OF CALH (NO. OF HOURS) m.11
e I tt. l + .i l O g^ N I i i i. I 'l 1 I e i I l I t i I g a 4 l O j WWOMPNJNwpOOOOOwwm N I A O M af e 8 NA O O83 O O O O O O O O O O O O O O w W d ED N 3. .J 8 if% 3 W EF* N 2 3m w o o D O O Cs J O O O O C O G 0 0 0 P W e4 2 J H W W M 2 4.4 3 2 >e
- D O
bi 4 M E 4 em n 4 U P1eee O+4P1O O O O O O O OCDe O O J >= W 4A W @ CL Z M c > W U. 64 M M MD -N M 4M Z ee O w .J Of 4 8 UW K e we O N @ N N J *4 O O 48 O O O ** *e O I I M 1> w N l O H >Q O 8 w MW W 3 .J W t.J m w Ch c sq ED M M W k W N D WO Oe o IA M4 M J O e3 O O u ** P1 O O O O O O O O C3 J 2 P. M M es 3 3 k O MW e 'a O , M 2 W M w 4 ed we e C3 O O O ee e e O az e3 O O O O O ** 2 ( 4 J H U P 4 U O 2 0 O en m .J G U O ha 4 O EL -2UW W W-W 2 3 2 2 H k MWgW2 MWM ti 2 68 22 O 2 cc 3 K WiseW M M M M M 2 3 3 2 Z E p W M EL O N 5.N O N-N e
_ _. _ _.. _ _ _. _ _ _ _._ _ _ _ _ _ % w _,, 24 HCUR SUMMA 8tY OF WIND SPEED DISTRIBUTION 18 g F PC - CRYSTAL RIVER 175 FT WINDS (SIG THETA) 1/1/ T5-6/30/ 75 TOTAL NUH9ER CF READINGS 4.1410 c E + 03 TOT AL NUMBER CF READINGS WITHOUT CALMS 4.13900E*03 3 WIto SPEED DISTRIBUTION, NO OF 005. gg. .LT.5 .50-3 5 3 51-7 5 7 51-12.5 12.51-13 5 18.51-24 0 GT 24 0 4 83 595 1833 1206 285 135 SUMMED OVER ALL DIRECTIONS WIND SPEE0 DISTRIBUTION VERSUS ST ABILITY CL ASS (NO OF CBS.) A B C D E F G 1 0 0 C 1 3 0 0 1 2 5-7 19 24 16 7 5 3 1? 29 81 206 152 69 'e 0 4 4 16 102 541 669 316 105 5 0 0 22 252 5 75 234 123 6 0 1 3 16 1 19 105 40 T 1 0 1 3 E1 56 13 g h
I FPC - CRTSTAL RIVER 175 FT WINDS (SIG THETAl 1/1/75-6/30/75 19 r n eeeeeeeeeeseooeeeeeeeeeeeeeeeeeeeeeeeeee SUMMED OVER ALL STABILITIES WINO SPEED VERSUS DIRECTICH (IN NUMBER OF OBS.) WIk0 SPEED (MPH) AT 53 METER LEVEL WIND . DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL - HNE 5 35 t,5 55 3 0 163 NE 14 37 1 31 62 1 1 246 ENE 4 43 177 104 . 6' 0 334 3 E-5 45 127 148 3 0 328 ESE 8 39 1C1' 69 3 1 221 g SE 7 40 146' 52 0 0 245 SSE 9 47 139 .36 7 0 238 5 3 30 99 59 47 15 253 SSW 3 24 68 98 72 53 338 SW 4 41 87 76 59 19 286 WSW 7 32 93 48 7 9 196 W 3 46 170 89 22 7 337 HNW 4 35 146 133 24 12 354 NH 3 38 125 93 26 17 382 NNW 3 28 61 35 3 1 131 N 1 35 78 49 2 0 165 TOTAL 83 595 1833 1206 2 85 135 4137 I PERIOUS OF CALM (NO. OF HOURSI - '4 203 NISSING DATA (NO. OF HOURS) IM t !B
- x..
0 2 L L A A T T O O T3S23112001132i2i6 T555372O3253413143 2 5 ) ) S 4 S 4 B 2 B 2 C > 00000000001000001 O >000000O0000U00000 F F C s O 5 e T R e R / E 4 s E 4 0 B 2 s B 2 3 M L-e M L - / U E9 e U E9 6 N V100000000000000000 N V1000000O0000100001 E E 5 N L N L 7 I I / ( R ( R 1 r E / b t 8 N T8 e. 1 O e1 O E1 I m-I H- ) T 3 T 3 A C
- 100000000000000000 C
31000000O00000D00C0 T E E S E AR BR H I I T D T' D T A A G SS SS I SU l2 SU I2 S AS f1 ( LR P- 'O AS H1 0 LR P-CE H81002000000C100004 CE M6421121O20100C01i6 S V ( V ( 1 O Y Y N TD D TD D I IE E e IE E C LE E ) s LE E I IP P S e IP P S T BS S R BS S R F A 1 U A T U TD D-O TD D-O 5 Sk N423201110000221218 H SN N 4114 2 41 O 1131313 0 3 9 H 7 I I 1 I I 2 1 W W F W W F Q O O ? V I O O N N E 3 ( 3 ( L 1O2010010G10000DO5 P 1D2OO1OO01120D000T P A L L T A A S C C Y Q F F C O O N N O S O S L O I L O C Gf A D OT A C P NCE E E E W W W W T I NCE E E E W W W W T I F IE! EN SES SWS 3i Wf O R IENEN SES SWS i WN l O R 4 4 WRNNEEESS5SSWWWNNNT E WRNNEEESSSSSWWWNNt T E I P I P D' D l 1 i g g l J I d4
~. - ~ ._._.._______-.______.____._,__-__._.__-_-_~_.;nr.,,. 21 FPC - CQYSTAL IIIVED 175 FT WIN 05 (SIG THET Al 1/1/T5-6/30/T5 STABILIT Y EL ASS 'C WIND SPEED VERSUS DIRECTION (IN NUMDER OF CBS.) Pi WIND. WIhD SPEED mph 1 AT 53 METER LEVEL DIRECTION 1-3 4-7 6-12 13-18 19-24 >24 TOTAL N9E -1 4 11 2 0 0 18 NE 3 7 18 4 0 0 32 ENE 1 7 16 3 0 0 27 E 2 7 13 6 3 0 28 ESE '1 5 8 5 1 0 20 SE O 2 T C 0 0 9 SSE 3 5-0 0 0 0 8 5 0 6 2 0 0 0 8 SSW 1 2 1 0 0 0 4 SW D 6 3 0 0 0 11 l WSW 2 9 7 0 1 1 2C H 2 7 9 0 0 0 18 WNW 1 2 1 1 0 0 5 g NW 1 2 4 1 0 0 8 HNW i 1 0 0 0 0 2 N O F 2 0 1 0 10 TOTAL 15 81 102 22 3 1 228 PERICOS OF CA(W (NO. OF HOURS) 0 ......ee........seeeeeeeeeeeeeee........ ST ABILITY CL ASS O WINO SPEED VERSUS DIRECTION (IN NUMBER OF 095.3 WIND HIND SPEED (MPH) AT 53 NETER LEVEL DIRECTION 1-3 4-7 6-12 13-18 ' 19-24 >24 TOTAL NNE 3 15 16 13 0 0 47 NE 5 18 89 31 0 1 144 ENE 1 17 51 24 2 0 95 g E 0 16 27 25 1 0 69 ESE 3 14 22 13 2 0 54 SE 2 11 24 16 0 0 53 SSE 1 13 23 8 0 0 45 S 1 13 23 6 3 0 46 SSW 0 12 34 a 2 1 57 SW 0 12 33 18 0 0 63 WSW 3 13 52 17 2 0 87 W 1 in 74 24 1 0 118 WNW 2 12 47 27 1 1 90 NW D 4 14 14 2 0 34 NNW 2 3 6 5 0 0 16 I N O 15 6 3 0 0 24 TOTAL 24 206 541 252 16 3 1042 O PERICOS OF CALF (NO. OF HOURS) 1
_ _ _ _ _ - 1 _ _ _ _~_ _ _ _ _ 5 - _ _ _ ~~. _ _ _ _ O _ f _ _ _ _ __f _ _ - - I FPC - CRYSTAL RIVER 175 FT WINDS (SIG THETA) 1/1/75-6/30/75 22 ST ABILIT Y CLASS E WIhG SPEED VERSUS DIRECTION (IN NUMBER OF OBSel WIND 'WIhD SPEED (HPHI AT 53 HETER LEVEL DIRECTION. 1-3 4-7 8-12 13-18 19-2 4 >24 TOTAL NNE 1 t 22 24 2 0 58 NE a 8 20 25 1 0 54 ENE i 10 85 55 4 0 155 E-1 12 30 44 2 0 89 ESE 2 7 26 19 0 0 54 SE 1 10 61 14 0 0 86 SSE 3 13 57 15 5 0 93 5 1 5 38 30 19 5 98 SSW 1 4 21 41 22 18 107 SW 2 14 32 36 27 12 123 WSW 0 6 30 31 3 6 76 W 0 12 68 59 15 5 159 WNW 1 13 74 85 6 4 183 .g NW i 15 61 61 12 to 160 NNW 0 9 13 17 1 1 41 N 1 5 31 19 0 0 56 TOTAL 16 152 669 575 119 61 1592 PERIODS OF CALP (NO. OF HOURS 3 - 3 ST ABILITY CL ASS F WIND SPEED VERSUS DIRECTION (IN NUMBER OF 085.3 WIND WIND SPEED (HPH) AT 53 HETER LEVEL DIRECTION 1-3 4-7 8-12 13-18 19-24 824 TOTAL NNE O 3 4 11 0 0 18 NE 2 0 1 2 0 0 5 ENE 1 3 18 17 0 0 39 g E O 8 29 36 0 0 73 ESE o 5 21 '13 0 0 39 SE 3 10 32 15 0 0 60 SSE O 8 40 6 2 0 56 S 1 4 23 18 24 10 80 SSW D 3 25 31 29 24 112 SW D 3 15 13 16 6 53 WSW G 3 4 0 1 1 9 W 0 0 16 4 5 1 26 WNW D 3 20 19 14 7 63 NW D 7 35 17 12 7 78 NNW D 7 16 11 2 0 36 3 N 0 2 17 21 1 0 41 TOTAL 7 69 316 234 106 56 788 li! PERIODS OF C ALH (NO. OF HOURS) 0 -}}