Forwards Evaluation of BAW-10100, Reactor Vessel Matls Surveillance Program-Compliance W/10CFR50,App H,For Oconee Class Reactors. Rept Acceptable
ML19319C114
Person / Time
Site: Oconee, Davis Besse  
Issue date: 02/19/1975
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Mallay J
BABCOCK & WILCOX CO.
Shared Package
ML19319C115 List:
References
NUDOCS 8001310476
Download: ML19319C114 (1)


Text

~.

4 1

f UNITED STATES NUCLEAR REGULATORY COMMISSION

/

W ASHIN GTON. D.

C.

20555 FEB 191575 Mr. James F. Mallay Manager, Licensing Babcock & Wilcox Company Nuclear Power Generation P. O. Box 1260 3

Lynchburg, Virginia 24505 i

l

Dear Mr. Mallay:

The Regulatory staff has completed its review of Babcock & Wilcox Topical Report BAW-10100, " Reactor Vessel Materials Surveillance Program - Compliance with 10 CFR 50, Appendix H, for Oconce Class Reactors". A su:tmary of our evaluation is enclosed for your information.

As a result of our review, we have concluded that BAU-10100 is acceptable for reference as a topical report in license applications uhen it is used to describe the reactor vessel material surveillance progran. This report is acceptable for B&W 177 fuel assc bly reactors (Oconce class) for which the surveillance specimens had not been prepared prior to issuance of.

Appendix H to 10 CFR 50 and for other new B&W plants.

The staff does not intend to repeat its revicu of BAU-10100 when it appears as a reference in an application.

In accordance with established procedure, it it requested that B&U issue j

a revised version of BAU-101CO within three months of receipt of this letter i

to include the NRC acceptance letter.

Should Regulatory criteria or regulations change, such that our conclusions regarding BAW-10100 are invalidated, you will be notified and given the i

opportunity to revise and resubmit the topical report for review, if you desire.

If you have any questions concerning our evaluation of this report, please Contact US.

t i

Sincerely,

/

4:4 0-f W

(

A.'Schwencer, Chief Light Water Reactors Branch 2-3 OJTro+

Division of Reactor Licensing e

Enclosure:

E

[ D kvaluation of BAW-10100

%*G2D/~

cc:

R. Schaffstall e

+is **

8001310

/