ML19319B038

From kanterella
Jump to navigation Jump to search

Tn Americas LLC Transmittal of Application for Revision 10 to Certificate of Compliance No. 9302 for the Model No. NUHOMS-MP197 Packaging
ML19319B038
Person / Time
Site: 07109302
Issue date: 11/13/2019
From: Shaw D
Orano USA, TN Americas LLC
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
Shared Package
ML19319B037 List:
References
E-55464
Download: ML19319B038 (3)


Text

Orano USA Columbia Office 7135 Minstrel Way Columbia, MD 21045 Tel: (410) 910-6900

@Orano_USA Enclosures transmitted herein contain SUNSI. When separated from enclosures, this transmittal document is decontrolled.

November 13, 2019 E-55464 U. S. Nuclear Regulatory Commission Attn: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852

Subject:

Application for Revision 10 to Certificate of Compliance No. 9302 for the Model No. NUHOMS-MP197 Packaging, Docket No. 71-9302

References:

[1] Revision 9 to Certificate of Compliance No. 9302 for the Model No. NUHOMS-MP197 Packaging

[2] NUHOMS-MP197 Transportation Package Safety Analysis Report, Revision 19, April 2019

[3] NRC Meeting Notice, Pre-application for Model No. NUHOMS-MP197HB Transportation Package, August 23, 2019

[4] Presentation Files for Pre-Application Meeting for Revision 10 to Certificate of Compliance No. 9302 for the Model No. NUHOMS-MP197 Packaging, Docket No. 71-9302, September 17, 2019

[5] TN Americas LLC letter E-55005 dated September 30, 2019,

Subject:

Application for Revision 10 to Certificate of Compliance No.

9302 for the Model No. NUHOMS-MP197 Packaging, Docket No.

71-9302 In accordance with 10 CFR 71.31(b) TN Americas LLC submitted an application dated September 30, 2019, for revision to the Certificate of Compliance (CoC) No.

9302 for the Model No. NUHOMS-MP197 Packaging [1].

Proposed changes to the MP197HB packaging design [2] were presented during a pre-application meeting held on September 5, 2019 [3]. The presentation files were submitted to the NRC Document Control Desk [4]. The NRC technical review staff held a telephone conference with TN Americas LLC (TN) on October 22, 2019, to discuss the information provided in the application. In response to the telephone conference, the application is supplemented to provide further justification for the packaging design changes. Enclosure 1 provides further explanation and justification for the design change items 1a and 2b, Enclosures 2 and 3 provide change pages for the package design Safety Analysis Report (SAR) Revision 20, 0

orano

Document Control Desk November 13, 2019 E-55464 Page 2 of 3 that replace any of the same pages provided in the original application, and Enclosures 4 and 5 provide additional calculation files. The enclosures provided with this letter supplement the Enclosures 1 through 5 submitted with the original application [5].

A revision to the Coe [1] is needed to add optional specifications to the package design that allow for fitment of impact limiter attachment bolts. The as-built condition of impact limiters does not allow for required thread engagement of the impact limiter bolts. The first use of the cask is scheduled for early January 2020 to ship low-level radioactive waste (LLW).

Should the NRC staff have any questions or require additional information regarding this submittal, please contact Mr. Peter Vescovi by telephone at 336.420.8325 or by e-mail at Peter.Vescovi@orano.goup. For any written correspondence, please include "To the Attention of Peter Vescovi."

Sincerely, Don Shaw Licensing Manager TN Americas LLC cc:

Bernard White, Senior Project Manager, U.S. Nuclear Regulatory Commission Dennis Lang, Senior Project Manager, Orano TN Americas Mike Valenzano, Senior Project Manager, Orano TN Americas

Enclosures:

1.

Summary of Changes to MP197HB SAR

2.

NUHOMS-MP197HB SAR, Revision 20, Replacement Pages and Drawings, Proprietary Version

3.

NUHOMS-MP197HB SAR, Revision 20, Replacement Pages and Drawings, Public Version

4.

Listing of Computer Files Contained in Enclosure 5

5.

Computer Files Associated with CoC 9302, Revision 1 O

6.

Affidavit Pursuant to 10 CFR 2.390

Document Control Desk E-55464 November 13, 2019 Page 3 of 3 Document Components:

001 Public Transmittal Letter.pdf, 577,595 bytes 002 SUNSI Encl 01 Summary of Changes.pdf, 341,997 bytes, Proprietary 003 SUNSI Encl 02 SAR P.pdf, 2,359,908 bytes, Proprietary 004 Public Encl 03 SAR NP.pdf, 1,687,699 bytes 005 SUNSI Encl 04 Computer File Listing for Enclosure 05.pdf, 13,150 bytes, Proprietary 006 SUNSI Encl 05 Computer Files, 21,378,626,095 bytes, Proprietary 007 Public Encl 06 Public Affidavit.pdf, 723,441 bytes OSM#1 (Disk):

001 Public Transmittal Letter.pdf, 577,595 bytes 002 SUNSI Encl 01 Summary of Changes.pdf, 341,997 bytes, Proprietary 003 SUNSI Encl 02 SAR P.pdf, 2,359,908 bytes, Proprietary 004 Public Encl 03 SAR NP.pdf, 1,687,699 bytes 005 SUNSI Encl 04 Computer File Listing for Enclosure 05.pdf, 13,150 bytes, Proprietary 007 Public Encl 06 Public Affidavit.pdf, 723,441 bytes OSM#2 (Enclosure 5 portable hard drive):

006 SUNSI Encl 05 Computer Files, 21,378,626,095 bytes, Proprietary OSM#3 (Public Information Only) (Disk):

001 Public Transmittal Letter.pdf, 577,595 bytes 004 Public Encl 03 SAR NP.pdf, 1,687,699 bytes 007 Public Encl 06 Public Affidavit.pdf, 723,441 bytes