October 3, 2019 MEMORANDUM TO: Christopher M. Regan, Deputy Director Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards FROM: Nishka Devaser, Project Manager /RA/

Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards

SUBJECT:

SUMMARY

OF SEPTEMBER 5, 2019, MEETING WITH TN AMERICAS TO DISCUSS A PROPOSED AMENDMENT TO THE NUHOMS MP197HB TRANSPORTATION PACKAGE Purpose TN Americas LLC (TN) requested the partially-closed meeting to provide to the U.S. Nuclear Regulatory Commission (NRC) staff an overview of upcoming proposed changes to the Model No. NUHOMS MP197HB (MP197HB) spent fuel transportation package.

Background

On September 5, 2019, a partially-closed meeting was held in Rockville, Maryland, at the request of TN with the NRC staff to discuss TNs upcoming proposed changes to the MP197HB transportation package. The list of meeting attendees, including those participating via telephone, is provided as an Enclosure.

The meeting was noticed on August 23, 2019 (see Agencywide Documents Access and Management System [ADAMS] Accession No. ML19235A220). The meeting attendance list is provided as an Enclosure, the non-proprietary presentation slides are located in ADAMS at Accession No. ML19262B018, and the proprietary presentation slides are provided in ADAMS at Accession No. ML19262B050.

CONTACT: Bernard White, NMSS/DSFM (301) 415-6577

C. Regan 2 Discussion TN is planning to submit an amendment request for the MP197HB package Certificate of Compliance No. 9302, Revision No. 10 to make changes to the package design as a result of an as-built condition. This amendment request is applicable only to the MP197HB.

The MP197HB transportation package is certified to transport spent nuclear fuel, and fabrication was recently completed on the first unit in Japan. The impact limiters were also recently fabricated separately in a facility in France. During testing prior to putting the package into use, it was identified that the impact limiters were not fitting securely onto the end of the package.

TN discovered that impact limiter is not securely fastening to the package because the 12 attachment bolts used to secure it to the package are not fully engaging into the threads of their respective bolt tunnels. The bolt tunnels are a thick-walled tubing that are welded to the shell.

The reason for the bolts not obtaining full engagement in the tunnel appears to be some interference between the bolt and the open end of the tunnel.

NRC staff had various questions regarding the structural and material layout of the impact limiter, associated attachment bolts, and respective bolt tunnels to which TN supplied answers.

TN stated that it plans to submit its application later this month.

Docket No.: 71-9302 EPID No.: L-2019-LRM-0059

Enclosure:

Meeting Attendees

C. Regan 3

SUBJECT:

SUMMARY

OF SEPTEMBER 5, 2019, MEETING WITH TN AMERICAS TO DISCUSS A PROPOSED AMENDMENT TO THE NUHOMS MP197HB TRANSPORTATION PACKAGE, DOCUMENT DATE:

DATED: October 3, 2019 DISTRIBUTION: D. Marcano G:\SFST\Bernie White\Casework\TN Americas\MP197HB\MP197HB Pre-App Meeting Summary, 190905.docx ADAMS Memo Accession No.: ML19270E475 OFFICE DSFM DSFM DSFM NAME NDevaser SFigueroa JMcKirgan DATE 09/25/19 09/26/19 10/03/19

MEETING ATTENDEES Meeting

Title:

PRE-APPLICATION FOR MODEL NO. NUHOMS MP197HB TRANSPORTATION PACKAGE

Participants:

TN Americas LLC and the NRC Date: September 5, 2019 Location: U.S. NRC Headquarters, 0-8-B04 NAME AFFILIATION In attendance Nishka Devaser NRC/NMSS/DSFM Meraj Rahimi NRC/NMSS/DSFM John Wise NRC/NMSS/DSFM Phone Attendees Olivier Gandou TN Americas Carlyn Green Ux Consulting Raheel Haroon TN Americas Dan Hayes TN Americas Abhijit Honrao TN Americas Dennis Lang TN Americas Jason Piotter NRC/NMSS/DSFM Antonio Rigato NRC/NMSS/DSFM Don Shaw TN Americas Duane Spencer TN Americas Venketa Venigalla TN Americas Peter Vescovi TN Americas Enclosure