NOV 7 1958 R. 3. Boyd, Assistant Director for 3aactor Projects, DRL CIRU

3. Levine, Assistant Director for Reactor Technolo2', DRL DUKE POWER COMPANY, OCONEE 1-3, DOCKET No. 50-269, 270, 237, REVISIONS TO PSAR Nilowins are coweents on the Duke ?wer Ccmpany latter of August 2'J,1968 revising the Oconee 1-3 ?SAR through Supplersent !!c. 5.

1.

Deletion of cooling ecils in primary shield.

Acceptable, for the 138 7 maxistsu stated.

8 2.

Favision, page SD-15 paragraph 4.2 Revised wording is acceptable, as the sense of the paragraph is not changed.

3.

Addition of sister splica technique, in principle, is acceptable. However, the sareple frequency is inadequate.

Ue recosemand that our proposed RTM cn Reinforcing Bar Cadwald Splices be followed.

4 Pages LE-1, SE-3 The change of liner plate designation from A 442, Grade 55 to A 516. Grade 60 is acceptable under AS!!E Pressure Vessel Code,Section III.

R. C. DeYotag, Acting Chief RT-1058 Containment & Component Technology Branch DRLtC&CT3 Ef:A Division of Reactor Licensing Dist ribution.* M Suppl. C E. G. Arndt.

DRL Readin's S. Levine

-ADRT Reading R. C. DeYoung C&CTB Reading-omcz>.D&tCACT3 '

DRLLC&CIH nRL ADHT, f

%gY jflXi'l fr f( rnd(tfa IaYoun'q-T M ne ?-

su m uc >

-=

om >

11/6[68_

,,_.11/ . /68 lif /

/18....

ewmac ass (ao.$4n u omer-:, mx:on.-o-me.

-7912190 [37

.