Westinghouse Electric Company - CoC 72-1026 Renewal Pre-Application Meeting Presentation Material
ML19318C855
Person / Time
Site: Westinghouse, 07201026
Issue date: 11/13/2019
From: Harper Z
Westinghouse
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
LTR-NRC-19-72
Download: ML19318C855 (24)


Text

Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852 Direct tel: (412) 374-5093 e-mail: harperzs@westinghouse.com LTR-NRC-19-72 November 13, 2019

Subject:

CoC 72-1026 Renewal Pre-Application Meeting Presentation Material Westinghouse Electric Company LLC (Westinghouse) is transmitting presentation material to the U.S. Nuclear Regulatory Commission to support a pre-application meeting regarding renewal of Certificate of Conformance (CoC) 72-1026. The meeting is scheduled for November 20, 2019.

Enclosed are the copyright notice and presentation materials. This submittal does not contain information proprietary to Westinghouse.

Zachary S. Harper, Manager Licensing Engineering cc: John McKirgan (NRC)

Kristina Banovac (NRC)

Suzanne Leblang (Entergy)

Enclosures:

1. Copyright Notice
2. CoC 1026 Renewal Pre-Application Meeting November 20, 2019

LTR-NRC-19-72 COPYRIGHT NOTICE The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of copies of the information contained in these reports which are necessary for its internal use in connection with generic and plant-specific reviews and approvals as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.390 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection notwithstanding. With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copies beyond those necessary for its internal use which are necessary in order to have one copy available for public viewing in the appropriate docket files in the public document room in Washington, DC and in local public document rooms as may be required by NRC regulations if the number of copies submitted is insufficient for this purpose. Copies made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.

Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

1 Robert D. Quinn Director Global Spent Fuel Storage and Disposal CoC 1026 Renewal Pre-Application Meeting November 20, 2019 LTR-NRC-19-72

LTR-NRC-19-72

3 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Agenda

  • Introductions
  • IP Acquisition
  • Background
  • FuelSolutions' Spent Fuel Management System
  • Regulations & Guidance
  • Proposed Content of CoC Renewal Application
  • Scoping Evaluation
  • Time-Limited Aging Analyses
  • Activities and Schedule
  • Questions FuelSolutions is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

LTR-NRC-19-72

4 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

IP Acquisition

  • Westinghouse Electric Company LLC (Westinghouse) acquired the intellectual property for the FuelSolutions Spent Fuel Management System from EnergySolutions
  • Westinghouse requested transfer of the Certificate of Compliance (CoC) for Spent Fuel Storage Cask, Model No.: FuelSolutions Spent Fuel Management System, Certificate No. 1026, Docket No. 72-1026, issued to BNG Fuel Solutions Corp on September 13, 2019 (ML19260C962)

5 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Background

  • CoC 1026 Effective Date: February 15, 2001

- Initial 20-year term

- Four previous approved amendments

- No Amendment is currently under review

  • Certificate Expiration: February 15, 2021
  • Renewal Application will request a 40-year renewal period
  • Seven W74/W150 systems loaded w/ 441 spent fuel assemblies and one loaded w/ GTCC and debris stored at Big Rock Point
  • Systems were placed in service between Nov 2002 and May 2003
  • No W21 canisters in service LTR-NRC-19-72

6 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

FuelSolutions System - Features

  • FuelSolutions Spent Fuel Management System (FuelSolutions System) is a fully integrated, canister-based system that provides for storage and transport of a broad range of spent nuclear fuel (SNF) assembly classes.
  • The primary Storage System components of the FuelSolutions System include the FuelSolutions storage cask, transfer cask and various FuelSolutions canisters.
  • The primary Storage System components are classified as important to safety in accordance with 10CFR72, Subpart G.
  • All other FuelSolutions System support equipment, with the exception of the transfer cask lifting yoke(s), canister vertical lift fixture, and empty canister lift fixture, is classified as not important to safety.

LTR-NRC-19-72

7 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

FuelSolutions System - Basic Components The FuelSolutions System is comprised of four basic components:

  • FuelSolutions W21 and W74 Canisters designed for dry storage of SNF in accordance with 10CFR72 and transportation in accordance with 10CFR71
  • FuelSolutions W150 Storage Cask provides passive vertical dry storage of a loaded canister in accordance with 10CFR72.
  • FuelSolutions W100 Transfer Cask provides canister loading, closure, and handling capability, in accordance with 10CFR50 and 10CFR72.
  • FuelSolutions TS125 Transportation Package - A transportation cask with impact limiters designed and licensed in accordance with 10CFR71 for off-site shipment of a FuelSolutions canister (Docket No. 71-9276)

LTR-NRC-19-72

8 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

FuelSolutions System - W21 / W74 Canisters W74 canister in service at BRP LTR-NRC-19-72

9 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

FuelSolutions System - Transfer Cask and Storage Cask FuelSolutions System - Basic Components LTR-NRC-19-72

10 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Regulations and Guidance

  • 10 CFR 72.240
  • ISG-2, Revision 2
  • NEI 14-03, Revision 2 (with NRC partial endorsement of revision 2)
  • EPRI CISCC Susceptibility Assessment Criteria Report (Sep 2015)
  • Lessons Learned (recent submittals)

Continuing to track and incorporate feedback from ongoing renewal efforts LTR-NRC-19-72

11 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Pre-Submittal Cask Inspection - Details

  • Pre-submittal Inspection performed at Big Rock Point on July 23, 2019
  • The inspection consisted of three separate tasks.

- Video inspection of access area in annulus between cask and canister

- Visual inspection of cask exterior

- Visual inspection of cask storage pad

  • Representative canister/cask selected by Entergy based on increased susceptibility for moisture intrusion and corrosion
  • Heat loads at the time of loading were within 0.5kw of each other and all storage casks were placed in service within months of each other.
  • Inspection found some minor observations however, storage cask, canister and associated pad all found without structural deficiencies
  • Inspection noted all parts of storage cask, canister and storage pad continue to perform their design function LTR-NRC-19-72

12 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Pre-Submittal Inspection - NRC Inspections at BRP

  • NRC INSPECTION REPORT 07200043/201800 (ML18330A231 - November 26, 2018)
  • No findings of significance were identified.

Photo at Big Rock Point - Dr. Nicole Fields, Health Physicist R-III - Rad Survey (from NRC Home Page Jan-2019)

LTR-NRC-19-72

13 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Pre-Submittal Inspection - Transfer Cask

  • FuelSolutions W100 Transfer cask was not included in July 2019 inspection
  • Utilitys most recent Transfer Cask inspections used in lieu of performing inspection
  • Inspections performed in 2013 thru 2018 reviewed by Jensen Hughes
  • Inspections included surface coatings, accessible welds, cover alignment, bolts and impact limiters
  • No identified deficiencies were found in components LTR-NRC-19-72

14 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Proposed Content of CoC Renewal Application Format and content per guidance from NUREG-1927

  • General Information
  • Scoping Evaluation
  • Time-Limited Aging Analyses
  • Supplemental Calculations
  • Changes to CoC 1026 Tech Specs LTR-NRC-19-72

15 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Scoping Evaluation

  • Scoping process:

- Review system drawings and identify SSCs to subcomponent level to determine SSCs In-Scope or Not In-Scope

- Create table with same arrangement as NUREG-2214 tables showing generic evaluation of potential aging mechanisms and effects requiring management for FuelSolutions System

- Summarize Scoping Evaluation results in table to identify SSCs that are subject to aging effects Scoping Criteria Criteria 1: SSC Important to Safety (ITS)

Criteria 2: SSC not ITS but failure could affect ITS function LTR-NRC-19-72

16 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Scoping Evaluation - Major Components Results SSC Description Criterion 1 Criterion 2 In-Scope SNF Assemblies Yes N/A Yes W21 / W74 Canister Yes N/A Yes W150 Storage Cask Yes N/A Yes W100 Fuel Transfer Cask Yes N/A Yes Auxiliary Equipment No No No ISFSI Storage Pad Yes*

No no ISFSI Security Equipment No No No

  • Per 72.212 Eval Report Appendix B, ISFSI pad-was upgraded to ITS, Category B due to Tech Spec requirements.

LTR-NRC-19-72

17 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Aging Management Review Evaluate Materials/Environments/Aging Effects per NUREG-1927

  • Identify materials associated with in-scope SSCs
  • Identify the service environments for these SSCs
  • Identify the aging effects and mechanisms requiring monitoring and/or management
  • Determine aging mechanism combinations for material environments, aging mechanisms and aging effects
  • Follow NUREG-2214 guidance for FuelSolutions System, Tables 4-21 (canister), Table 4-22 (storage cask) and Table 4-23 (transfer cask)

LTR-NRC-19-72

18 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Time Limited Aging Analyses

  • Follow NUREG-2214 guidance for FuelSolutions System, Tables 4-21 (canister), Table 4-22 (storage cask) and Table 4-23 (transfer cask)
  • Planned TLAAs (as a minimum)

- Canister or transfer cask material fatigue, evaluate per design code

- Neutron absorber boron depletion

- Fuel basket support rod thermal aging

- Fuel basket bolt loss of preload

- Storage or transfer cask coating degradation

- Other aging issues, if applicable

  • TLAAs will provide conclusions or basis for conclusion for capability of SSC to maintain intended function for extended operation LTR-NRC-19-72

19 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Aging Management Programs Prepare Aging Management Programs (AMP) per NUREG-1927

  • Address 10 elements from NUREG-1927 on aging effects
  • Review other recent renewal projects
  • Follow NUREG-2214 guidance for FuelSolutions System, Table 4-21 (canister), Table 4-22 (storage cask) and Table 4-23 (transfer cask)

- Localized corrosion and stress corrosion cracking of welded SS canister

- Loss of fracture toughness and ductility of fuel basket support rod

- Loss of pre-load of fuel basket bolts

- Reinforced concrete structures of storage cask

- Monitoring of storage cask metallic surfaces

- Coating degradation on storage cask carbon steel

- Transfer cask wear, general, pitting, crevice and galvanic corrosion 1

W21 approved for HBU (60 GWd/MTU) fuel. However, no W21 is loaded to date.

Consider if HBU Fuel Monitoring and Assessment AMP is appropriate / necessary LTR-NRC-19-72

20 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Activities and Schedule Planned schedule of activities CoC expires on Feb 15, 2021 Conditions for renewal (10CFR72.240)

- Deadline timely for renewal submittal: January 16, 2021 (72.240(b))

- Existing CoC will not expire until the application for renewal has been determined by NRC

  • Planned submittal in Sept 2020
  • Discussion of NRC review schedule LTR-NRC-19-72

21 Westinghouse Non-Proprietary Class 3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Thank you! Questions?