.U!!S D3CUMENT C0!!TAINS P00R QUAUTV PAGES p

PCO VIRGINI A ELECTRIC AND POWER COMPANY. RfCNMONO. VIRGINI A 23261 June 27, 1980 Mr.

..w i 2 C'".cil.'y, sir 7ctu Serial '.o.

5521 Uffice of Insocctico ?x inforecatn*.

U.S. tk.r.iear i mulawry Coe. mission

% GC & C:.uac:wa.N scrivo II 00ckat Nos. 23-E3 lui vsrietti 5t ect, iuite 21~.50-33v Atlar t 2, G.'r;is XJ03 10:.M.

00.. r.,

, ?-7 Oc67 ;r.

'reill :

f

_ve ; tenir..u cur ;ul;w c1 thC 1.d.

.wiiutin 7 /-i-r,r.or:- m ui Uni..

.2 :st;_.ita; ;,,.;; Aetle.n cua fur onir.1 is na nu,ust,1, im.

Inc atta;.m u TL;e 1 su;. car;zus ;ur tir.oi..,,8 ter u.ilt.:. m.:rovli; s in ;n sce of tne., nit ; stor.us.

o A surcary or :.r.c ncncearor:arces ;cantifi"c en Unit 2 foli;ws:

.'.antnnfonnees ienntifica

.]rior ta recelat af thi:

cwra;.ane license (r.oril 11, 13:0) e re ranart.Ic.. ;.sr tre Dravisiens of iMn' G.5%).

Gur final 5F 2) rev]rt W.N.

1..;;4 at :' crc 5 1, J 6) oroviaec a e xticta lic'.ar cf tais3 nancontornnc u.

Constructi]n wr,r <, is u_ ;olete on all of tr.s 1

.cr. cent a r.tanc i s 1/ntif irc af ter recelat ;t tno coeretinc 11cansa ere reporteo by Licensee Jivant neaort 60-G2/Gli; retarencs cor 14 cr.y letter (5.a.

' 6C-007 of v;. y*

D, 19E).

Ccnstruction cor< :n tre mocificatict's reLuired to ccr ect v.crrorfarn nces is al:0 cc.;.ciate.

17 Our IOtter....1 3rr af mveaner 9, ig79, we notifiac yo.; tr,c cur revien 3r at. lid.in N -iw m vinn.sr rJct.ec. ny a c ri.e erncerninu 2r01i fin resuonse s ectrLa (~is) curves snich ae recortec on havemoer 5,

197i ay 100.~El.1-(e), Srt 21, -inu Licen+ee Event depcrt U.9) f7r units 1 sm 2 inuleated

.e that we excatted to fiac systems eitn actn.>r:cles, a ciscr.enet Sultetbi 7F-14 v dv-: w l ;nt Ano tne 4 5 curve are-i n.

In ta? r/'irc :.:rNr.wn of xc '.etter, es si..taa tnat ae..oulo wor < actn crociees concurrentay,

snc ths.t. fr.r cas-s involving,:t, r':1: s, Mii!;.eti.;rc arc. repartir.a to toe.6C would ae hancleo tnrouc,n ;c.2 tec cr;aica 1CCF.6._.5n :-) ano LIR; tnat ".

action ac.er 1.d. -ui te tin 79-14 will ne limitea to recorting sucn cases in the final tulletin texrt."

To satisfy this cor.ituent, oelow is a list of MS4's (1scutric aioiro orowin;. ) anicts requirea mooificaticos.

were.41 rectea cy botn proolems ana 03 S

6007 99)

/ 1 01 thit 1

'6X No.

Line Function ll715-lClG Main Steam - At:cs. Oino IClH Main Steam Delay Heat Release 107F Cuenen Spray cump Section Line 11SC Cn7. Cooling (CC) Sucaly to 4HR HX 11SV CC from acren 'secevary (9.R) Dist111cte M 113#

CC to Liquio Waste i BR Distillate HX 1:1h Wefueling durir. Wro Suction '_ines units 1 % 2 11715-105A Sarvice Water from CC HX 105C Service Water Purna 01senstge ll8G CC Return from Recire. Air Colls Unit 2 11715-11914 CC to CC Pump Suction We censicer this to be cur final report en lilletin 79-1A for North Anna Unit 2.

Our finsi report for Unit I will follow corcletion of cur review.

If you have any questions, please incuire.

,.m ve trulyyours, l

i, i v s

  • C. crodi, Y.(Lh':,

ll(:

>//.

/

/

Senior Vicd* resident - Power / Stdicn Engine = ring and Ccostruc o cc: Mr. Victor Stc11c, Director CFfice of Inmction & Enforcefrent VM Harold R. Denton, dir:ctor Office of Nuclear Reactor Peculation

TABLE 1*

SUMMARY

OF VALVE WEIGHT REVIEW Unit 1 Unit 1 Unit 2 S&W Scope.

Non-S&W Scope S&W Scope Total Number of Computer-Analyzed Seismic 143 21 143 MSK's Total Number of MSK's with Acceptable Review 120 17 131 Number of MSK's containing no valves 42 36 Number of MSK's acceptable per previous 7

2 I.E.Bulletin 79-04 review Number of MSK's with valve weights 9

44 within 10% of actual weight Number of MSK's acceptable after 62 17 49 engineering evaluation Total Number of MSK's Requiring Evaluation or 2

1 0

Vendor Verification of Valve Weights Number of MSK's requiring vendor valve 0

0 O

weight verification before review can start Number of MSK's identified which require 2-1 0

further evaluation Number of MSK's acceptable after noncon-21 3

12 formances were corrected or justification developed for continuous operation

  • This table is a summary of the computer analyzed seismic MSK's.

"Non-S&W Scope" MSK's are those analyzed originally by Teledyne and Nuclear Services.

All Unit 2 MSK's were analyzed by S4W.

Note: An MSK is an isometric piping drawing.

C2752/8

.