Forwards LER 80-037/01T-0
Date released: 11/28/2019 Download: ML19318C373


LER 80-037/01T-0:on 800613,Westinghouse Notified Util of Potential for Damage to Centrifugal Charging Pumps Due to Inadequate Flow Following Secondary Side High Energy Line Rupture.Caused by Inadequate Consideration During Design
ML19318C379
Person / Time
Site: Farley 
Issue date: 06/27/1980
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318C379 (3)
Forwards LER 80-037/01T-0
ML19318C372
Person / Time
Site: Farley 
Issue date: 06/27/1980
From: Clayton F
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318C372 (1)