ML19318C040

From kanterella
Jump to navigation Jump to search
Forwards LER 80-010/01T-0
Date released: 11/28/2019 Download: ML19318C040


LER 80-010/01T-0:on 800516,during Cold Pressure Test,Leakage Discovered at Gasket Joint Between Pump Casing & Pump Cover on Reactor Coolant Pumps RC-3A,3B & 3C.Closure Studs Corroded by Boric Acid.Leaks Caused by Deteriorated Gaskets
ML19318C050
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 06/17/1980
From: Fleuhr J
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19318C050 (6)
Forwards LER 80-010/01T-0
ML19318C039
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 06/23/1980
From: Stevens S
OMAHA PUBLIC POWER DISTRICT
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19318C039 (1)