ML19318B792
| ML19318B792 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 05/14/1980 |
| From: | Seyfrit K NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Gary R TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| References | |
| NUDOCS 8006300063 | |
| Download: ML19318B792 (1) | |
Text
,
LPDR TICR UfJITE D ST ATES s' p 5 %,#'
NSIC NUCLEAR REGULATORY COMMISSION CENTRAL FILES 0.*
e' Rs cioN ov 611 RY AN PL AZ A D RIVE, SUITE 1000
- f.h.,Q'
)
c f*
- C ARUNGToN, TEX AS 76012 *kh/l m,
- e May 14, 1980 In Reply Refer To:
RIV Docket Nos.
50-445/IE Circular No. 80-12 50-446/IE Circular No. 80-12 Texas Utilities Generating Company ATTN:
Mr. R. J. Gary, Executive Vice President and General Manager 2001 Bryan Tower Dallas, Texas 75201 Gentlemen:
The enclosed IE Circular No. 80-12, is forwarded to you for information.
If there are any questions related to your understanding of the suggested actions, please contact this office.
Sinc e rely,,e--
/
71 l,
,f Y / ",, '
/
Ra'rl V. Seyfrit
/
I Director
Enclosures:
1.
IE Circular No. 80-12 2.
List of Recently Issued IE Circulars N
t8006acoM3
SSINS No.: 6830 UNITED STATES Accession No.:
NUCLEAR REGULATORY COMMISSION 8005050052 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 IE Circular No. 80-12 Date:
May 14, 1980 Page 1 of 2 VALVE-SHAFT-TO-ACTUATOR KEY MAY FALL OUT OF PLACE WHEN MOUNTED BELOW HORIZONTAL AXIS Description of Circumstances:
Tennessee Valley Authority has identified and reported to the NRC a nonconformance on a Bettis Robot-Arm actuator installed on a Pratt Butterfly Valve at the Sequoyah nuclear plant.
It is reported (ref. attached 10 CFR 50.55(e) report) that a valve became inoperable when the valve-shaft-to-actuator key fell out of place.
It is further noted that the orientation of this valve assembly was such that the operator was on the bottom of the valve (below the horizontal axis).
The Pratt Butterfly Valve furnished with Bettis actuator is designed with a press-fit keyway connection valve / actuator. We believe other manufacturer's connections may be of similar construction and therefore subject to this failure mode.
On May 1, 1980, Pratt Company sent letters to their customers who have these connections (enclosed list). They recommended that their customers review their installation of such connections, and if the keyway is oriented below horizontal, make one of the following field modifications:
1.
Add a spacer bushing, or shim plate to fill the void between the top of the shaft and the indicating plate on the actuator.
2.
Locally upset the end of the valve shaft in the area of the keyway using a hand punch in such a way that the key could not work loose.
3.
Install new keys of longer length which extend above the end of the valve shaft whereby the key is up to the actuator plate and could not slip down if inverted.
Recommended Action for Licensee Co We request that all plants make th DUPLICATE DOCUMENT connections similar to the above d not supplied by thoee particular m Entire document previously entered are susceptible to tailure, one of into system under:
appropriate action should be taken ANO
@Ob No. of pages: