ML19318A405

From kanterella
Jump to navigation Jump to search
Forwards LER 80-068/01T-0
Date released: 11/28/2019 Download: ML19318A405


LER 80-068/01T-0:on 800530,informed That Wide Range Steam Generator Level Transmitters Not Qualified to Withstand post-accident Environ.Caused by Design Error.Qualified Transmitters Being Obtained for Installation
ML19318A413
Person / Time
Site: Sequoyah 
Issue date: 06/13/1980
From: Reynolds R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318A413 (2)
Forwards LER 80-068/01T-0
ML19318A404
Person / Time
Site: Sequoyah 
Issue date: 06/13/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318A404 (1)