Text

--

.

,

^'

'

.

e

.

,

.

O

m

~

U. S. ATOMIC ENERGY COMMISSION

.

REGION II

DIRECTORATE OF REGULATORY OPERATIONS

.

RO Inquiry Report No.: 50-313/73-1Q/CDR

Licensee:

Arkansas Power and Light Company

Sixth and Pine Streets

Pine Streets

Pine Bluff, Arkansas

71601

License No.: CPPR-57

Facility: Arkansas Nuclear One, Unit 1

Descriptive Title: Lack of Material Control - Weld Filler Material

.

, l .0[ s .

. ' .

l- ,

.3

, -

.

S'i '_ .1

//l/$/ / '

Prepared By:

<

V. L. Brownlee, Reactor Inspector

Ddtei

Facilities Section

Facilities Construction Branch

O

~ A.

Date and Manner AEC Was Informed:

A licensee representative contacted Region II by telephone on

January 4 and 5, 1973.

B..

Description of Particular Event or Circumstance:

AP&L was informed by letter from the Babcock and Wilcox Company

(B&W) that test reports for several heats of weld filler material

used in the fabrication of the ANO-1 steam generators did not

,

i

indicate tensile or impact properties. This item was identified

in the B&W Barberton, Ohio shops during an audit performed by the

Babcock and Wilcox Quality Control Organization.

C.

Action By Licensee:

'

AP&L notified Region II, January 4, 1973, that this item was

considered a reportable deficiency. AP&L management further

determined on January 5, 1973, that this item was reportable

as required by 10 CFR 50.55(e), and a report will be issued

l

accordingly.

!

l

The licensee stated that to the best of his kncwledge, the above

information did not contain proprietary information.