Amend 16 to License DPR-54,revises App a & App B to Tech Specs Re Surveillance Testing of Reactor Internal Vent Valves
ML19317G781
Person / Time
Site: Rancho Seco
(DPR-54-A-016, DPR-54-A-16)
Issue date: 11/30/1977
From: Reid R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19317G763 List:
References
NUDOCS 8004010607
Download: ML19317G781 (4)


Text

.

[o=na,g*

u UNITED STATES NUCLEAR REGULATORY COMMISSION y'

g j

WASHINGTON, D. C. 2044 s

O

%, v...../

SACRAMENTO MU:

IPAL UTILITY DISTRICT DOCKET NO. 50-312 RANCHO SECO NUCLEAR GENERATING STATION AMENDMENT TO FACILITY OPERATING LICENSE Anendment No. 16 License No. OPR-54 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Sacramento Municipal Utilitv District (the licensee) dated September 27, 1977: complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

s l

8004010

-s

. Accordingly, the license is amended by changes to the Technical 2.

Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DpR-54 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 16, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

This license amendment is effective as of the date of its 3.

issuance.

FOR THE NUCLEAR REGULATORY COMMISSION kv b0lb',

w Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors

Attachment:

Chat oes to the Technical Spec 4 fications Date of Issuance: No' ember 30, 1977 l

ATTACHMENT TO LICEtiSE AMENDMEtlT N0'. 16 FACILITY OPERATING LICENSE NO. DPR-54 DOCKET NO. 50-312 Revise Appendix A as follows:

Remove Pages-Insert Pages 4-8

, 4-8 The change on the revised page is shown by a marginal line.

j

)

1 1

i u................

~ -veillance Standarcs TABLE 4.1-2 MlHIMUM EQUIPME!iT TEST FREQUEliCY Test Frecuency Jtem Rod drop times of Each refueling shutdown 1.

Control rods all full length rods 2.

Control rod Movement of each Every two weeks movement rod 3.

Pressurizer code Setpoint 1 each refueling interval safety valves 4.

Main Steam safety Setpoint 2 per steam generator each refueling interval valves Functional Each refueling interval 5.

Refueling system prior to handling fuel.

interlocks 6.

Turbine steam stop Movement of each Monthly valves valve Calculated inventory weekly 7.

Reactor Coolant Leakage Leakage check daily.

system 8.

Charcoal and high Charcoal and HEPA Each refueling interval and efficiency filters filter for iodine at any time work on filters and particulate could alter their integrity.

removal efficien-cies.

00P test

'on HEPA filters.

Freon test en charcoal filter, units.

9.

Fire pumps and Functional Monthly pcwer supplies 10.

Reactor Building Functional Each refueling interval isolation trip Functional Each refueling interval

11. Spent fuel prior to fuel handling.

cooling system 12 '.

Turbine Overspeed Calibration Each refueling interval Trips Manual Actuation,I Each refueling interval 13.

Internals Vent Remote Visual in-Valves spection,2 and verify that valve not stuck ocen.

1. Verif ying through rnanual actuation that the valve is fully open with a force of < AC? lbs. (applied vertically ur ard).ible surfaces to evaluate observed
2. Check visually acce surface, irregularities.

4-8

-