.A' c np&pr_

~

x

'REGULATONY INFURMATInd DISTRIBUTION SYSTEM (RIDS)

DIGTRIBUTION+3R INCOMING MATERI AL 50-302 RECi REID Rcu 9RG: GTEWART W P DOCDATE: 07/21/78

.NRC FL PWR DATE RCVD: 07/25/78

. DOCTYPE: LETTER NOTARIZED: NO COPIES RECEIVED SUDJECT:

LTR 3 ENCL 40 FORWARDING REPT BAW-11?O, REV.

1, JIJLY, 1978 ENTITLED: " CRYSTAL RIVER UNIT 3 LIC CONSIDERATION FOR CUNTINUED CYCLE 1 OPERATION WITHOUT BURNAELE POISON ROD

~

ASSEM6 LIES AND ORIFICE ROD ASSEMBLIES" NOTARIZED 07/21/7':.

I f

PLANT NAME: CRYSTAL RItdR tt3 REVIEWER INITIAL:

XJM DISTRIBUTOR INITIAL.q

                                  • DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ******************

LGENERAL DISTRIBUTION FOR~f..'ER ISSUANCE OF OFERATING LICENSE.

(DIGTRIEUTION COLE A001)

FOR ACTION:

ER CHIEF ORBn4 BC**W/7 ENCL SD s

INTERNAL:

-' REG FI4E**W/ ENCL (.2.)

_OELD**LTR ONLY NRC PDR**W/ ENCL T L'E7*W/2 CNCL HANAUER*aW/ ENCL CORE PERFORMANCE BR**W/ ENCL AD FOR SYG & FROJ**W/ ENCL ENGINEERING SR**W/ ENCL REACTOR ' SAFETY ER**W / ENCL PLANT SYSTEMS BR4*W/ ENCL EED**W/ ENCL EFFLUENT TREAT SvS**W/ ENCL J.

MCGOUGH**W/ ENCL EXTERNAL:

LPDR'S CRYSTAL RIVER, FL**W/ ENCL TERA **W/ ENCL NSIC**W/ ENCL

.ACRS CAT B**W/16 ENCL N

ENCLCh-DISTRIOUTION:

LTR h CGNTROL NCR-

~~

l/t jl.

SI2E; SP+32PL

-***6******************************

_THE END 8 0 03-20 0 $36 A

STATE OF FLORIDA COUNTY OF PINELLAS W.P. Stewart states that he is the Director, Power Production, of Florida Power Corporation; that he is authorized on the part of said company to sign and file with the Nuclear Regulatory Connission the information attached hereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information and belief.

I)

J.

i~oxOr L W.P. Stewart Subscribed and sworn to before me, a Notary Public in and for.the State and County above named, this 21st day of July,1978.

/

/

Notary Public

~

Notary Public, State of Florida at Large.

My Commission Expires: July 25, 1980 l

l

Mr. Robert W. Reid.

Page Two July 21, 1978 It is our belief that continued operation of Crystal River Unit No. 3 with

+

the modifications as described, represents no substantial safety hazard or unresolved safety concerns.

Please advise if further -discussion of the enclosed report is desired.

Sincerely,-

FLORIDA POWER CORPORATION W.P. Stewart WPS/QBD/ emf l

i-

yp C:%

,f f D

?s ff33Maj N s 0%Yh{;;(& 84 n'

23

+m m s Q6 b h}Tvf 80

^

[J}3

/

s 3 *s o d n

W. P. STEWART. DIR EdTOR

' ~ ' ~

~

POWER PRODUCTION.

co,,,,,,,n,

'/

July 21, 1978 Mr. Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors U.S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Florida Power Corporation

Dear Sir:

Enclosed are forty-three (43) copies of the Report BAW-1490, Rev. 1, July, 1978, Crystal River Unit 3 Licensing Considerations for Continued Cycle 1 Operation Without Burnable Poison Rod Assemblies and Orifice Rod Assem-blies.

On June 2,1978 we transmitted to you copies of BAW-1490 which provided -

analys'es of continued Crystal River Unit No. 3 operation with Burnable Poison Rod Assemblies (BPRA's) removed. Since that time, two additional core alterations have been proposed. These are:

1) the complete removal of all Orifice Rod Assemblies (0RA's) except for two (2) wh.ich will be used in fuel assemblies containing the primary neutron sources, and 2) the repla~ement of four (4) fuel assemblies with appropriate fuel assemblies acquired f rom Duke Power Company (these 4 assemblies are referred to as Batch 1-X in BAW-1490, Rev. 1).

BAW-1490, Rev.1 is intended to superseda BAW-1490, and incorporates the effects of all three modifications, i.e., BPRA removal, ORA removal and fuel assemblies replacement.

Section 6., Proposed Modifications to Technical Specifications, of BAW-1490, Rev. 1 is included for completeness of information only. A formal request for Technical Specification changes will be filed under separate letter acccmpanied by the appropriate licensing fee.

Y s\\ 6fQ

-. 3 i General Office 3201 Thirty-fourth Street South e P O. Box 14042. St. Petersburg Flonda 33733 e 813-866-5151 pV l