Text
-
4 g~'rSMUD SACRAMENTO.MUillCIPAL UTILITY DISTRICT C 1708 59th Street. Box 15830. Sacramento. Cahforma 95813;(916) 452 3211 RJR 76-410 October 12, 1976 fi Mr. R. H. Engelken Directer of Regulatory Operations NRC Operations Office, Region V 1990 N. California Boulevard Walnut Creek Plaza, Suite 202 1
Walnut Creek, California 94596
}1 Re: Operating License DPR-54 Docket No. 50-312 4
Reportable Occurrence 76-12
~'
Dear Mr. Engelken:
,n This documentation is in conjunction with the telephone discussion I
I
)
of October 12, 1976, between Mr. R. Colombo and Mr. R. 'Dodds concerning
\\s_ /
Reportable Occurrence 76-12.
On October 7, 1976, Rancho Seco personnel were preparing for a plant heatup. Due to a misinterpretation of the actual shutdown calcu-lation procedure, the actual shutdown with Groups 1-4 withdrawn was
.411' A</<, well below the required -1.0% A</< for shutdown conditions.
Upon discovery of the error, suf ficient boron was aeded to increase the actual shutdown better than -1.47% Ac/K.
This report is being submitted in accordance with the requirements
, i of Regulatory Guide 1.16, Revision 4, Section C.2.a(8).
A detailed report will be submitted within 14 days.
Jtaspectfbily,,
'\\ Q. N l
'~
J Gk R.J.Rohiguez
^
Plant Superintendenp Rancho Seco Unit Me 1
7y i
k' RJR:RWC: sal
/
,/
,/
8002 210 pop f
~
2,.
,1, r.,
s,,,,u
.,,,, s. t.
2a.,
r 2,
so02 t4,
,: 2,: c, c21t,o,~.2 L
-~
J