m

1) UKE POWER COMPANY Powen Dutz.otxo 422 SouTu Catuncar Srnest, CHARLOTTE, N. C. 2820 A. C. Tit a ns P. O. Box 2170

$smeon wcs Pettiotav Pecs,veten n=o Tamasmisteow July 17, 1974 Mr. Norman C. Moseley, Director Directorate of Regulatory Operations U. S. Atomic Energy Commission Region II - Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Re:

RO:II:FJ 50-287/74-6

Dear Mr. Moseley:

Please find attached our response to Iten I.A contained in RO Inspection Report 50-287/74-6.

Duke Power Company does not consider any information contained in RO Inspection Report 50-287/74-6 to be proprietary.

Very trul: yours,

_1s gf

. d. [

A. C. Thies ACT:vr

.\\

Attachment s

S 8001100[7y

~g DUKE POWER COMPANY OCONEE UNIT 3 RESPONSE TO RO INSPECTION REPORT 50-287/74-6 I.A.

Inadequate Identification of Baseline Calibration Blocks r

The calibration blocks used for the Oconee Unit 3 piping baseline inspection were supplied by B&W in 1970 as part of the original oconee Unit 1 baseline inspection program.

Since Appendix B to 10CFR50 was issued af ter the cali-bration blocks had been supplied to Oconee, records and data did not meet all requirements of Criterion XII.

Furthermore, the blocks were modified, but appropriate changes were not made to the drawings.

To correct this situation, new drawings of the calibration blocks have been made. A spectrographic analysis has been made on each of the blocks where records of an analysis could not be found., The revised drawings and the chemical analysis data were included in a revision to the Preoperational Inspection Manual on June 28, 1974.

Identification numbers will be added to the blocks to assure proper control prior to July 19, 1974.

l l

l 4

Y

s s'

Ltr to Duke Power Company fm.N. C. Moseley dtd AUG 2 1974 Ltr to N. C. Moseley fm Duke Power Company dtd July 17, 1974 DISTRIBUTION:

H. D. Thornburg, RO RO:lig (4)

Directorate of Licensing (4) g R Central Files PDR Local PDR NSIC DTIE, OR State D

4 O

e e